TITLE

Mathematical modelling of extracorporeal circulation: simulation of different perfusion regimens

AUTHOR(S)
Bauernschmitt, R.; Naujokat, E.; Mehmanesh, H.; Schulz, S.; Vahl, C.; Hagl, S.
PUB. DATE
September 1999
SOURCE
Perfusion;1999, Vol. 14 Issue 5, p321
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Computer- and sensor-aided control of the heart-lung machine is considered a major goal for perfusion sciences for the next few years. At present, control of perfusion is achieved by surgeons, anaesthesiologists and perfusionists making short-term decisions, which leads to variations of the perfusion regimens between different centres and even between different teams in the operating theatre. As the basis for an integrated control of extracorporeal circulation (ECC), we proposed a mathematical model for simulating haemodynamics during pulsatile perfusion. This model was then modified to allow it to simulate the effects of different perfusion regimens on arterial haemodynamics and whole body oxygen consumption. The model was constructed on a PC using MATLAB/SIMULINK. The human arterial tree was divided into a multibranch structure consisting of 128 segments characterized by their particular physical properties. Peripheral branches were terminated by a resistance term representing smaller vessels like arterioles and capillaries. Flow and pressure were expressed by the intensity of current and voltage in an electrotechnical analogon; inductivity, resistance and capacitance were implemented according to the physical properties of the arterial tree and the rheology of blood. The effects of different perfusion regimens (pulsatility, flow amount, acid-base regulation) were studied. After introducing an input signal to the model, flow and pressure waves established themselves throughout the simulated arterial tree. During the simulation experiments, marked differences among different perfusion regimens were displayed by the model. Variations in acid-base management mainly influenced the distribution of perfusion: during simulation of low-flow perfusion (1.2 l/min/m[sup 2]), cerebral blood flow was 6.2 ml/s using an alpha-stat regimen, while it was increased to 9.4 ml/s during pH-stat, caused by an implementation of reduced cerebral resistance. Whole body oxygen consumption was predominantly regulated by the perfusion rate. While central venous oxygen saturation was calculated to be 84.7% during simulation of high-flow perfusion (2.4 l/min/m[sup 2]), it dropped to 70% during simulation of low-flow perfusion regimens. The model proved to be useful for a realistic simulation of different perfusion regimens. Therefore it can be considered a continuing step for the derivation of a `state' observer leading to the realization of an automatically controlled heart-lung machine.
ACCESSION #
2301677

 

Related Articles

  • Use of a large bore syringe creates significantly fewer high intensity transient signals (HITS) into a cardiopulmonary bypass system than a small bore syringe. Rudolph, James L; Tilahun, Daniel; Treanor, Patrick R; Pochay, Val E; Mahendrakar, Meetali A; Sagar, Praveen; Babikian, Viken L // Perfusion;Jan2006, Vol. 21 Issue 1, p67 

    Introduction: High intensity transient signals (HITS) have been reported to occur following perfusionist intervention during cardiac surgery. This study investigates the relationship of the syringe bore, injection rate, and HITS created. Methods: Syringes (10 mL) with a male luer-lock connection...

  • Editorial. Taylor, K. // Perfusion;1999, Vol. 14 Issue 5, p319 

    Editorial. Discusses the introduction of computer control systems into the cardio-pulmonary bypass circuit; Views on mathematical modelling of extracorporeal circulation; Evolution of automated control systems.

  • An update on perfusion safety: does the type of perfusion practice affect the rate of incidents related to cardiopulmonary bypass? Stammers, A.H.; Mejak, B.L. // Perfusion;May2001, Vol. 16 Issue 3, p189 

    Cardiopulmonary bypass (CPB) techniques vary among adult and pediatric patients undergoing cardiac surgery. This may result in a differential conduct of CPB between various aged patients. The present study reports on perfusion incidents occurring in hospitals using extracorporeal circulation. An...

  • Vacuum-assisted venous return in pediatric cardiopulmonary bypass. Berryessa, R.; Wiencek, R.; Jacobson, J.; Hollingshead, D.; Farmer, K.; Cahill, G. // Perfusion;Jan2000, Vol. 15 Issue 1, p63 

    Vacuum-assisted venous return (VAVR) has been reported to offer benefits for adults undergoing cardiopulmonary bypass (CPB), such as improved venous return, lowering priming volume (by eliminating the need to prime the venous line), and the use of smaller venous cannulae. All these benefits...

  • Affinity pump system: a new peristaltic blood pump for cardiopulmonary bypass. Jaggy, C.; Lachat, M.; Leskosek, B.; Zünd, G.; Turina, M. // Perfusion;Jan2000, Vol. 15 Issue 1, p77 

    An in vitro study has been carried out to assess the pump performance of a new peristaltic, extracorporeal displacement pump (Affinity) for cardiopulmonary bypass. The pump system consists of a pump rotor (0--110 rpm), a pump chamber, a venous reservoir with a 5/8 connecting tube and the...

  • Selective pulmonary pulsatile perfusion with oxygenated blood during cardiopulmonary bypass attenuates lung tissue inflammation but does not affect circulating cytokine levels†. Santini, Francesco; Onorati, Francesco; Telesca, Mariassunta; Menon, Tiziano; Mazzi, Paola; Berton, Giorgio; Faggian, Giuseppe; Mazzucco, Alessandro // European Journal of Cardio-Thoracic Surgery;Dec2012, Vol. 42 Issue 6, p942 

    OBJECTIVE Improved respiratory outcome has been shown after selective pulsatile pulmonary perfusion (sPPP) during cardiopulmonary bypass (CPB). No contemporary study has analysed the impact of sPPP on alveolar and systemic inflammatory response in humans. METHODS Sixty-four patients undergoing a...

  • Perfusion technique for nonhaemic cardiopulmonary bypass prime in neonates and infants under 6 kg body weight. Merkle, Frank; Boettcher, Wolfgang; Schulz, Fritz; Koster, Andreas; Huebler, Michael; Hetzer, Roland // Perfusion;Jul2004, Vol. 19 Issue 4, p229 

    Background: Cardiopulmonary bypass (CPB) in neonates and infants is associated with significant haemodilution when priming of the CPB circuit is accomplished without transfusion of homologous blood components. The degree of haemodilution and, thus, the requirements for blood transfusion may be...

  • Editorial. Taylor, K. M. // Perfusion;May2005, Vol. 20 Issue 3, p127 

    Presents an introductory statement to the 2005 issue of the journal "Perfusion." Focus of the featured articles on aspects of Extracorporeal Membrane Oxygenation; Occurrence of bubbles during cardiopulmonary bypass; Performance characteristics of bubble traps.

  • Editorial. Taylor, K. M. // Perfusion;Jan2007, Vol. 22 Issue 1, p7 

    The author reflects on the value of mini-bypass. A study on the reduction in blood product usage with the routine use of mini cardiopulmonary bypass (CPB) systems illuminates on the mechanistic benefits of mini-bypass. The author acknowledges mini-bypass' ability to deliver improved hemostasis...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics