TITLE

A validated method for the determination of traces of UV filters in fish using LC–MS/MS

AUTHOR(S)
Meinerling, Maria; Daniels, Marion
PUB. DATE
December 2006
SOURCE
Analytical & Bioanalytical Chemistry;Dec2006, Vol. 386 Issue 5, p1465
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An analytical method for the determination of UV filter substances in fish tissue has been developed and validated using benzophenone-3, 3-(4-methylbenzylidene)-camphor, 2-ethylhexyl-2-cyano-3,3-diphenyl-2-propenoate and 2-ethylhexyl 3-(methoxyphenyl)-2-propenoate as target analytes. The fish fillets were homogenised and extracted by Soxhlet extraction. The extracts were run through a clean-up process including gel permeation chromatography followed by solid-phase extraction. Quantification of the compounds was performed using liquid chromatography with tandem mass spectrometric detection. Blank fish as well as spiked blank fish were analysed to validate the analytical method. The analytical method developed has the multiple advantages of enabling separation, simultaneous identification and quantification of each of the four selected compounds in a single run. Contamination of blank samples and abnormally high concentrations in spiked samples were avoided by taking extensive precautions during the fish preparation procedure. The method was validated in accordance with internationally accepted criteria, such as specificity, accuracy and repeatability. The combination of LC with tandem mass spectrometry ensures a high level of specificity. The accuracy of the method was reported as the mean recovery rate for the analytes in the sample matrix. Mean recoveries were in the range 86–108%. The precision is expressed as the relative standard deviation, and in all but one of the cases was 20% or below. The accuracy of the method allows residue analyses to be performed on biological matrices at ng/g levels. The determined limit of quantification for each analyte was 8 ng/g fish. For all spiking levels ≥8 ng/g, relative standard deviations were ≤ 20%.
ACCESSION #
22897004

 

Related Articles

  • Hollow-Fiber Flow Field-Flow Fractionation.  // Current Analytical Chemistry;Oct2007, Vol. 3 Issue 4, p310 

    The article offers information on the theory and instrumentation and the developments on hollow-fiber flow field-flow fractionation (HF FlFFF). It says that the idea of HF FlFFF was made in 1974, wherein a HF ultrafiltration (UF) membrane channel was used to experimentally survey electrical...

  • LC/MS Software.  // Laboratory Equipment;Sep2002, Vol. 39 Issue 5, p1 

    Features the proprietary MassLynx 4.0 software from Waters Corp. which converts raw liquid chromatography/mass spectrometry data into knowledge.

  • Field-Flow Fractionation Coupled with ICP-MS for the Analysis of Engineered Nanoparticles in Environmental Samples. Mitrano, Denise; Ranville, James; Neubauer, Ken; Thomas, Robert // Spectroscopy;Sep2012, Vol. 27 Issue 9, p36 

    The article focuses on the use of field-flow fractionation (FFF) coupled with inductively coupled plasma-mass spectroscopy (ICP-MS) to analyze engineered nanomaterials (ENMs) in environmental samples. It says that the capabilities of FFF coupled with ICP-MS shows an effective way to separate,...

  • Mass spectrometry: gaining mass appeal in proteomics. Gershon, Diane // Nature Methods;Jun2005, Vol. 2 Issue 6, p465 

    Reports on the proliferation of commercially available tools for proteomic studies, driven by the interest of the research community in analyzing large sets of proteins in biological samples. Mass spectrometry (MS)-based proteomic strategies; Fractionation and depletion of proteins in...

  • Maximizing the Peak Production Rate in Off-line Comprehensive Two-dimensional Liquid Chromatography with Mass Spectrometry Detection. Eeltink, Sebastiaan; Dolman, Sebastiaan; Ursem, Mario; Swart, Remco; McLeod, Fraser; Schoenmakers, Peter J. // LC-GC Europe;Sep2009, Vol. 22 Issue 8, p404 

    This article describes an optimization strategy to obtain the best possible performance in the shortest analysis time—called the peak production rate—for comprehensive off-line two-dimensional liquid chromatography. The demands on column technology (particle size and column length)...

  • Particle size characterization of titanium dioxide in sunscreen products using sedimentation field-flow fractionation-inductively coupled plasma-mass spectrometry. Atitaya Samontha; Juwadee Shiowatana; Atitaya Siripinyanond // Analytical & Bioanalytical Chemistry;Jan2011, Vol. 399 Issue 2, p973 

    Sedimentation field-flow fractionation-inductively coupled plasma-mass spectrometry (SdFFF-ICP-MS) was successfully applied to investigate particle size distribution of titanium dioxide (TiO) in sunscreen samples after hexane extraction to remove organic components from the samples. Three brands...

  • A simple methodological validation of the gas/particle fractionation of polycyclic aromatic hydrocarbons in ambient air. Kim, Yong-Hyun; Kim, Ki-Hyun // Scientific Reports;7/3/2015, p11679 

    The analysis of polycyclic aromatic hydrocarbons (PAH) in ambient air requires the tedious experimental steps of both sampling and pretreatment (e.g., extraction or clean-up). To replace pre-existing conventional methods, a simple, rapid, and novel technique was developed to measure gas-particle...

  • Korea Focus.  // LC-GC Asia Pacific; 

    The article focuses on several researches performed in Korea. It states that the development of analytical methods using LC-MS to detect the concentration of peptides from proteome is done at Korea Basic Science Institute, Daejon. It mentions about the use of FFF technique for the...

  • Production of reference materials for the detection and size determination of silica nanoparticles in tomato soup. Grombe, Ringo; Charoud-Got, Jean; Emteborg, Håkan; Linsinger, Thomas; Seghers, John; Wagner, Stephan; Kammer, Frank; Hofmann, Thilo; Dudkiewicz, Agnieszka; Llinas, Meritxell; Solans, Conxita; Lehner, Angela; Allmaier, Günter // Analytical & Bioanalytical Chemistry;Jun2014, Vol. 406 Issue 16, p3895 

    A set of four reference materials for the detection and quantification of silica nanoparticles (NPs) in food was produced as a proof of principle exercise. Neat silica suspensions were ampouled, tested for homogeneity and stability, and characterized for total silica content as well as particle...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics