TITLE

USE OF METAL-ON-METAL TOTAL HIP RESURFACING FOR THE TREATMENT OF OSTEONECROSIS OF THE FEMORAL HEAD

AUTHOR(S)
Mont, Michael A.; Seyler, Thorsten M.; Marker, David R.; Marulanda, German A.; Delanois, Ronald E.
PUB. DATE
November 2006
SOURCE
Journal of Bone & Joint Surgery, American Volume;Nov2006 Supplement 3, Vol. 88-A, p90
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Recently, with the advent of improved metal-on-metal prostheses, total hip resurfacing has emerged as a viable arthroplasty option. However, it remains controversial whether this procedure should be used in patients with osteonecrosis when the femoral resurfacing component is cemented onto dead bone. The purpose of this study was to analyze the clinical and radiographic outcomes of metal-on-metal total hip resurfacing arthroplasty in patients with osteonecrosis of the femoral head. In addition, this group was compared with a matched group of patients who were diagnosed as having osteoarthritis. Methods: Forty-two osteonecrotic hips that were treated with a metal-on-metal total hip resurfacing arthroplasty were studied. They were matched by gender, age, prosthesis, surgeon, and surgical approach to forty-two osteoarthritic hips that were treated with the same metal-on-metal prosthesis. In the osteonecrosis group, there were twenty-five men and eleven women, and in the osteoarthritis group, there were twenty-eight men and thirteen women. The mean age at the time of surgery was forty-two years. Patients were followed both clinically and radiographically for a mean of forty-one months. Results: The clinical outcomes were similar for both groups, with a good or excellent outcome in thirty-nine hips (93%) with osteonecrosis and a good or excellent outcome in forty-one hips (98%) with osteoarthritis. In each of the two groups, there were two failures that required conversion to a standard total hip arthroplasty. Survivorship curves were similar for the two patient groups. Conclusions: The short-term results for metal-on-metal total hip resurfacing for this challenging patient population with osteonecrosis were excellent and comparable with those seen in patients with osteoarthritis. We await long-term results to see if these early results are maintained. Level of Evidence: Prognostic Level II. See Instructions to Authors on jbjs.org for a complete description of levels of evidence.
ACCESSION #
22878565

 

Related Articles

  • METAL-ON-METAL HIP RESURFACING IN OSTEONECROSIS OF THE FEMORAL HEAD. Revell, Matthew P.; McBryde, Callum W.; Bhatnagar, Sharad; Pynsent, Paul B.; Treacy, Ronan B. C. // Journal of Bone & Joint Surgery, American Volume;Nov2006 Supplement 3, Vol. 88-A, p98 

    Background: The treatment of end-stage osteonecrosis of the femoral head remains a challenge to the orthopaedic surgeon. Historically, total hip arthroplasty for this condition has been associated with poor rates of survival and function when compared with total hip arthroplasty for the...

  • UNCEMENTED TOTAL HIP ARTHROPLASTY IN YOUNG ADULTS WITH OSTEONECROSIS OF THE FEMORAL HEAD: A COMPARATIVE STUDY. Mont, Michael A.; Seyler, Thorsten M.; Plate, Johannes F.; Delanois, Ronald E.; Parvizi, Javad // Journal of Bone & Joint Surgery, American Volume;Nov2006 Supplement 3, Vol. 88-A, p104 

    Background: The outcome of uncemented total hip arthroplasty in patients with osteonecrosis of the femoral head in general, and in young adults in particular, remains largely unknown. This study evaluated the clinical and radiographic results of uncemented total hip arthroplasty in young adults...

  • USE OF AN ALUMINA-ON-ALUMINA BEARING SYSTEM IN TOTAL HIP ARTHROPLASTY FOR OSTEONECROSIS OF THE HIP. Seyler, Thorsten M.; Bonutti, Peter M.; Jianhua Shen; Naughton, Marybeth; Kester, Mark // Journal of Bone & Joint Surgery, American Volume;Nov2006 Supplement 3, Vol. 88-A, p116 

    Background: The results of total hip arthroplasty in patients with osteonecrosis of the femoral head are not always optimal. The use of alumina-on-alumina interfaces in young and active patients may decrease wear and lower the rate of aseptic loosening of the implant and appears to be an...

  • Poor results of the cementless total hip arthroplasty with a nonporous coated acetabular component: AcSys Shearer Cup. Masahide Ikema; Masamizu Oyama; Atsushi Kita; Kanichi Funayama // Journal of Orthopaedic Science;Sep2007, Vol. 12 Issue 5, p466 

    Abstract Background  This study followed patients for a minimum of 7 years after primary total hip arthroplasty using cementless acetabular components and evaluated their outcomes. Methods  We followed 73 patients (75 hips), who had undergone total hip arthroplasty with cementless...

  • Re-dislocation after revision total hip arthroplasty for recurrent dislocation: a multicentre study. Yoshimoto, Kensei; Nakashima, Yasuharu; Aota, Shigeo; Kaneuji, Ayumi; Fukui, Kiyokazu; Hirakawa, Kazuo; Nakura, Nariaki; Kinoshita, Koichi; Naito, Masatoshi; Iwamoto, Yukihide // International Orthopaedics;Feb2017, Vol. 41 Issue 2, p253 

    Purpose: Although most case of dislocations after total hip arthroplasty (THA) can be managed with conservative treatment, recurrent dislocation may require surgical intervention. This multicentre study was conducted to evaluate the re-dislocation rate after revision THA for...

  • Nyakban rögzülÅ‘ szárral végzett csípőízületi totál endoprotézis rövid távú eredményei klinikánkon Két eset ismertetése. HUNOR, ANTAL; KINGA, SZUPER; PÉTER, THAN // Magyar Traumatológia, Ortopédia, Kézsebészet, Plasztikai Seb;2013, Vol. 56 Issue 3, p233 

    The range of clinical indications for hip prosthesis implantation is getting wider. The younger the patient is at the time of prosthesis implantation, the higher is the probability of a later revision surgery. Short-stemmed femoral shaft bone preserving prostheses have been developed for such...

  • Biomechanical analysis and quantitative analysis of bone scintigraphy on thrust plate hip prosthesis. Goto, Toshihiko; Yasunaga, Yuji; Takahashi, Kazuhiro; Ochi, Mitsuo // Archives of Orthopaedic & Trauma Surgery;Jul2004, Vol. 124 Issue 6, p357 

    Introduction: To study the load distribution of the thrust plate hip prosthesis (TPP, Sulzer Medica, Baar, Switzerland) on femoral bone, a TPP insertion group and intramedullary cemented stem insertion group were pre- pared with the use of embalmed femoral anatomic specimens, and strain on the...

  • In-vitro method for assessing femoral implant—bone micromotions in resurfacing hip implants under different loading conditions. Cristofolini, L.; Varini, E.; Viceconti, M. // Proceedings of the Institution of Mechanical Engineers -- Part H;Jan2007 Supplement 1, Vol. 221, p943 

    Although prosthesis-bone micromotion is known to influence the stability of total hip replacement, no protocol exists to investigate resurfacing hip implants. An in-vitro protocol was developed to measure prosthesis-bone micromotions of resurfaced femurs. In order to assess the effect of all...

  • Intraosseous myelolipoma within proximal femoral metaphysis in a patient with previous prostate cancer: a case report. PAPAPIETRO, NICOLA; MARTINELLI, NICOLÒ; IPPOLITO, MASSIMILIANO; AMATO, CIRINO; DENARO, VINCENZO // Hip International;Jul-Sep2009, Vol. 19 Issue 3, p283 

    We report on a case of an osteolytic lesion of the femur in a patient with previous prostate cancer, affected by hip osteoarthritis. computed tomography of the femur demonstrated the presence of fat in the lesion. computed tomography-guided fine needle aspiration biopsy revealed mature adipose...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.