TITLE

Dynamic atomic force microscopy operation based on high flexure modes of the cantilever

AUTHOR(S)
Girard, P.; Ramonda, M.; Arinero, R.
PUB. DATE
September 2006
SOURCE
Review of Scientific Instruments;Sep2006, Vol. 77 Issue 9, p096105
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We show the interest of the high flexure modes of vibration for amplitude-controlled atomic force microscopy (AFM). In connection with AFM working conditions, we define the stabilization time threshold of the oscillating sensor. We show experimentally that, in both air and vacuum, the stabilization time decreases appreciably when the order of the flexure mode of the cantilever increases. Under ambient conditions, this increases the possible scan speeds by about one order of magnitude. Under vacuum and using standard sensors, the amplitude-controlled conditions are satisfied for harmonics equal to or higher than the second. Morphology imaging is then obtained. Thus, high flexure mode AFM easily extends the well known amplitude-controlled operations from ambient to vacuum environment, which allows new AFM applications.
ACCESSION #
22578504

 

Related Articles

  • Force gradient detection under vacuum on the basis of a double pass method. Portes, L.; Girard, P.; Arinero, R.; Ramonda, M. // Review of Scientific Instruments;Sep2006, Vol. 77 Issue 9, p096101 

    The feasibility of detecting electrostatic gradients in the linear regime is shown under vacuum by combining intermittent contact atomic force microscopy and a double pass method. To achieve our goal, different flexure mode orders were employed. We show that the sensitivity of the frequency or...

  • Optical beam deflection noncontact atomic force microscope optimized with three-dimensional beam adjustment mechanism. Yokoyama, Kousuke; Pearl, T.P.; Ochi, Taketoshi; Sibener, S.J.; Uchihashi, Takayuki; Ashino, Makoto; Sugawara, Yasuhiro; Suehira, Nobuhito; Morita, Seizo // Review of Scientific Instruments;Jan2000, Vol. 71 Issue 1 

    We present a design and performance of an optical beam deflection noncontact atomic force microscope (nc-AFM). The optical deflection detection system can be optimized by the three-dimensional beam position adjustment mechanism (the slider which mounts laser diode module, the spherical rotors...

  • Analysis of the high-frequency response of atomic force microscope cantilevers. Rabe, U.; Turner, J.; Arnold, W. // Applied Physics A: Materials Science & Processing;1998, Vol. 66 Issue 7, pS277 

    Abstract. In most commercial atomic force microscopes, dynamic modes are now available as standard operation modes. Acoustical vibrations of atomic force microscope cantilevers can be excited either by insonification of the sample or by vibration of the clamped cantilever end. The resulting...

  • Effect of Contact Position and Tip Properties on the Flexural Vibration Responses of Atomic Force Microscope Cantilevers. Abbasi, M.; Mohammadi, A. Karami // International Review of Mechanical Engineering;Mar2009, Vol. 3 Issue 2, p196 

    The characteristic equation of the flexural vibration of an AFM cantilever with different contact position is derived. Because the tip is not exactly located at one end of the cantilever, the cantilever is modeled as two beams. The effects of tip length, effective mass, contact position and...

  • New Products. Mandelis, Andreas // Review of Scientific Instruments;Jan2011, Vol. 82 Issue 1, p019501 

    No abstract available.

  • Alpha and recoil track detection in poly(methyl methacrylate) (PMMA)--Towards a method for in vitro assessment of radiopharmaceuticals internalized in cancer cells. Myhra, S.; Falzone, N.; Chakalova, R. // Review of Scientific Instruments;2014, Vol. 85 Issue 3, p1 

    A method for detection and characterization of single MeV α-particle and recoil tracks in PMMA photoresist by atomic force microscopy (AFM) analysis has been demonstrated. The energy deposition along the track is shown to lead to a latent pattern in the resist due to contrast reversal. It has...

  • Microfabrication of Silicon/Ceramic Hybrid Cantilever for Scanning Probe Microscope and Sensor Applications. Wakayama, Takayuki; Kobayashi, Toshinari; Iwata, Nobuya; Tanifuji, Nozomi; Matsuda, Yasuaki; Yamada, Syoji // AIP Conference Proceedings;2003, Vol. 696 Issue 1, p264 

    We present here new cantilevers for scanning probe microscopy (SPM) and sensor applications, which consist of silicon cantilever beam and ceramic pedestal. Silicon is only used to make cantilever beams and tips. Precision-machinery-made ceramics replaces silicon pedestal part. The ceramics was...

  • Calibration of the torsional spring constant and the lateral photodiode response of frictional force microscopes. Feiler, Adam; Attard, Phil; Larson, Ian // Review of Scientific Instruments;Jul2000, Vol. 71 Issue 7 

    We present a direct one-step technique to measure the torsional spring constant of cantilevers used for lateral or friction measurements with the atomic force microscope. The method simultaneously calibrates the photodiode response to the angular deflection of the cantilever. It does not rely...

  • Characterization and optimization of scan speed for tapping-mode atomic force microscopy. Sulchek, T.; Yaralioglu, G. G.; Quate, C. F.; Minne, S. C. // Review of Scientific Instruments;Aug2002, Vol. 73 Issue 8, p2928 

    Increasing the imaging speed of tapping mode atomic force microscopy (AFM) has important practical and scientific applications. The scan speed of tapping-mode AFMs is limited by the speed of the feedback loop that maintains a constant tapping amplitude. This article seeks to illuminate these...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics