ABSTRACT
Work in our laboratory has been directed at the development of a new class of instrumentation that can directly measure ambient aerosol absorption through photothermal interferometry. The hallmark of this approach is its ability to directly measure aerosol absorption without interference from aerosol scattering since the signal originates from the thermal dissipation of the spectrally absorbed energy. While the principle of the photothermal technique for the detection of aerosols was demonstrated in the mid-1980s, this interferometric technique remains a laboratory technique largely due to sensitivity to mechanical vibrations and other environmental factors that result in unwanted signal interference and commensurate reduction in detection sensitivity. In order to realize its application outside the laboratory, a folded Jamin interferometer design has replaced both the traditional Mach-Zehnder and unfolded Jamin configurations. The folded Jamin affords many advantages, which include high degree of common mode noise rejection, insensitivity to rotation and translation of optical components, inherent double pass configuration, and compact size. In this article, we report on the performance of this optical configuration and present representative data for both absorbing and nonabsorbing aerosols.
ACCESSION #
22567767

 

Related Articles

  • Improvement of sensitivity of photothermal deflection spectroscopy by a double pass method. Horita, Susumu; Miyagoshi, Eiji; Ishimaru, Masahiko; Hata, Tomonobu // Review of Scientific Instruments;Mar92, Vol. 63 Issue 3, p1909 

    In order to improve the sensitivity of photothermal deflection spectroscopy, we propose a double pass method, in which a pump beam is passed twice through the sample using a total reflector set behind the sample. A one-dimensional theoretical analysis of this method is developed and is verified...

  • Vacuum-compatible vibration isolation stack for an interferometric gravitational wave detector TAMA300. Takahashi, R.; Kuwahara, F.; Majorana, E.; Barton, Mark A.; Uchiyama, T.; Kuroda, K.; Araya, A.; Arai, K.; Takamori, A.; Ando, M.; Tsubono, K.; Fukushima, M.; Saito, Y. // Review of Scientific Instruments;Jun2002, Vol. 73 Issue 6, p2428 

    Interferometric gravitational wave detectors require a large degree of vibration isolation. For this purpose, a multilayer stack constructed of rubber and metal blocks is suitable, because it provides isolation in all degrees of freedom at once. In TAMA300, a 300 m interferometer in Japan,...

  • Sensitive photothermal interferometric detection method for characterization of transparent plate... Bincheng Li; Yanzhuo Deng; Jieke Cheng // Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3649 

    Discusses the use of a sensitive photothermal interferometric detection technique, in which an interference fringe pattern formed by overlapping two reflected probe beams from the front an drear surfaces of the sample, to measure the photothermal signal. Intensity distribution of interference...

  • Design and development of an interferometer with improved angular tolerance and its application to x-y theta measurement. Menq, Chia-Hsiang; Chia-Hsiang Menq; Zhang, Ji-Hua; Ji-Hua Zhang; Shi, Jian; Jian Shi // Review of Scientific Instruments;Dec2000, Vol. 71 Issue 12 

    Plane mirror interferometers are widely used in the measurement of x-y motions. Although large range planar motion can be measured, it suffers from very tight angular tolerance. In this article an interferometer system having improved angular range and linear resolution is developed. In the...

  • Optothermal study of small single particles. Moksin, M.M. // Review of Scientific Instruments;Sep95, Vol. 66 Issue 9, p4716 

    Presents the suitability of the thermal wave detection technique to examine nonspherical particulate contaminants on products. Analysis of the thermal wave signal decay curves by using two existing decay models; Goodness of fit of the models to the experimental data.

  • Ultrahigh-resolution pyroelectric thermal-wave technique for the measurement of thermal diffusivity of low-concentration water-alcohol mixtures. Matvienko, Anna; Mandelis, Andreas // Review of Scientific Instruments;Oct2005, Vol. 76 Issue 10, p103904 

    Thermal diffusivities of water-methanol and water-ethanol mixtures were measured using a thermal-wave cavity with two techniques: conventional single-pulse photopyroelectric frequency scans and the common-mode-rejection demodulation dual-pulse scheme. The frequency-scan measurements showed...

  • Real-time computer-optimized electron coincidence spectrometer. Murray, Andrew J.; Turton, Brian C. H.; Read, Frank H. // Review of Scientific Instruments;Jun92, Vol. 63 Issue 6, p3346 

    An electron coincidence spectrometer utilizing real-time optimization and control by a standard IBM 80286 personal computer is described. Details of the system hardware and software are presented together with a description of the optimization routine adopted for maintaining the tuning of the...

  • Direct measurement instrument for lattice spacing on regular crystalline surfaces using a scanning tunneling microscope and laser interferometry. Rerkkumsup, Pongpun; Aketagawa, Masato; Takada, Koji; Watanabe, Tomonori; Sadakata, Shin // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1205 

    An instrument for direct measurement of the lattice spacing on regular crystalline surfaces, which incorporates a scanning tunneling microscope (STM) and a phase modulation homodyne interferometer (PMHI), was developed. Our aim was to verify the applicability of the length measurement method in...

  • Advanced interferometric phase and amplitude noise measurements. Rubiola, Enrico; Giordano, Vincent // Review of Scientific Instruments;Jun2002, Vol. 73 Issue 6, p2445 

    The measurement of the close-to-the-carrier noise of two-port radio frequency and microwave devices is a relevant issue in time and frequency metrology and in some fields of electronics, physics, and optics. While phase noise is the main concern, amplitude noise is often of interest. Presently...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics