ABSTRACT
The author comments on the paper "Combined Anterior Plus Posterior Stabilization Versus Posterior Short-Segment Instrumentation and Fusion for Mid-Lumbar (L2 to L4) Burst Fractures," by P. Korovessis et al. He notes the study uses a randomized trial design comparing combined anterior and posterior surgery with posterior short-segment transpedicular fixation (SSTF) alone. He contends that the study confirms the usefulness of an SSTF through a posterior approach alone for mid-lumbar fractures.
ACCESSION #
22449166

 

Related Articles

  • HYBRID EXTERNAL FIXATION AS A NEW TREATMENT METHOD FOR PERIPROSTHETIC FEMORAL FRACTURE. Pafilas, Dimitrios; Kourtzis, Nikolaos // Journal of Bone & Joint Surgery, American Volume;Jan2006, Vol. 88-A Issue 1, p188 

    The article focuses on hybrid external fixation as a new treatment method for periprosthetic femoral fracture. Treatment options available are bed rest; traction and cast immobilization; operative fixation with Rush rods, supracondylar nails, and plates with or without bone-grafting; and...

  • Stiffness measurement of the neocallus with the Fraktometer FM 100®. Schmickal, T.; Recum, J.; Wentzensen, A. // Archives of Orthopaedic & Trauma Surgery;Dec2005, Vol. 125 Issue 10, p653 

    Introduction: The assessment of fracture healing is subjective, and neither radiology nor manual examination allows a reliable determination of bone healing. Fracture healing control in the treatment of tibia shaft fracture with external fixator by a stiffness measurement system (Fraktometer FM...

  • A new device for the internal fixation of wrist fractures: preliminary communication. Myles, John W. // Journal of the Royal Society of Medicine;Mar1978, Vol. 71 Issue 3, p186 

    The article presents a case report on a 17 year old girl who uses the wrist fixation device that is designed to control Colles' fracture by internal splintage. Techniques and control of the Colles' fracture is described to difficult and complicated. Other device including bone grafting prevents...

  • Efficacy of volar and dorsal plate fixation for unstable dorsal distal radius fractures. Chang-Hong Chen; Rong-Kui Zhou; Hua-Qing Zhen; Lei Huang; Ya-Jun Jiao // International Journal of Clinical & Experimental Medicine;2015, Vol. 8 Issue 3, p4375 

    Objective: To compare the efficacy of volar and dorsal plate fixation for unstable dorsal distal radius fractures. Methods: Forty-seven cases were selected from patients undergoing surgical reduction and internal fixation treatment in our hospital from August 2006 to October 2010, with 21 males...

  • Treatment of displaced midshaft clavicular fractures: A comparison between smooth pin and LCDCP and reconstruction plate fixation. Tabatabaei, Saeid; Shalamzari, Sharareh // Pakistan Journal of Medical Sciences;Oct2011, Vol. 27 Issue 5, p1129 

    Objectives: To compare the results of internal fixation of the clavicular fractures by pin and LCDCP and reconstruction plates in displaced fractures of middle third. Methodology: Between April 2008 to December 2010 a total of 68 clavicular fractures were treated in Razi hospital of Jundishapur...

  • Influence of Screw Design, Sex, and Approach in Scaphoid Fracture Fixation. Meermans, Geert; Verstreken, Frederik // Clinical Orthopaedics & Related Research;Jun2012, Vol. 470 Issue 6, p1673 

    Background: Screw fixation of scaphoid fractures has gained popularity. A long central screw has been shown to be biomechanically advantageous. Questions/purposes: We compared the ability of different screw designs to obtain this goal and determined the influence of sex and approach on screw...

  • Biomechanics of External Fixation. Moss, David P.; Tejwani, Nirmal C. // Bulletin of the NYU Hospital for Joint Diseases;2007, Vol. 65 Issue 4, p294 

    External fixation for the purpose of bony realignment has been in practice since the early 1900s and is widely used today. External fixators are primarily used for trauma but may also be used for deformity correction and arthrodesis, among other applications. The advantages of external fixation...

  • POSIBILITÄ‚Å¢I TERAPEUTICE ÃŽN FRACTURILE HUMERUSULUI DISTAL TIP B3.3 - CLASIFICAREA AO (ARBEITSGEMEINSCHAFT FÃœR OSTEOSYNTHESEFRAGEN). Ciubară, A. B.; Puha, B.; Alexa, O. // Acta Medica Transilvanica;sep2011, Vol. 16 Issue 3, p66 

    The objective of this study was the identification of the therapeutic possibilities for the fractures of the distal humerus type B3.3 - classification AO. In a series of 773 cases of distal humerus fractures, only 5 cases were identified with this type of fracture. In the treatment of this type...

  • Nanofibers and Nanoparticles for Orthopaedic Surgery Applications. Nair, Lakshmi S.; Laurencin, Cato T. // Journal of Bone & Joint Surgery, American Volume;Feb2008 Supplement 1, Vol. 90-A, p128 

    The ability of nanostructures to elicit altered cell behaviors, including cell adhesion, proliferation, orientation, motility, integrin expression, cytoskeletal organization, and modulation of intracellular signaling, has raised heightened interest in these materials for various biomedical...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.