TITLE

TWO-PART SURGICAL NECK FRACTURES OF THE PROXIMAL PART OF THE HUMERUS

AUTHOR(S)
Edwards, Sara L.; Wilson, Nicole A.; Li-Qun Zhang; Flores, Steven; Merk, Bradley R.
PUB. DATE
October 2006
SOURCE
Journal of Bone & Joint Surgery, American Volume;Oct2006, Vol. 88-A Issue 10, p2258
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Successful internal fixation of fractures of the surgical neck of the humerus can be difficult to achieve because of osteopenia of the proximal aspect of the humerus. The purpose of this study was to compare the biomechanical stability of a proximal humeral intramedullary nail and a locking plate for the treatment of a comminuted two-part fracture of the surgical neck in a human cadaver model. Methods: Twenty-four cadaveric humeri were instrumented with use of either a titanium proximal humeral nail (PHN) or a 3.5-mm locking compression plate for the proximal part of the humerus (LCP-PH). The specimens were matched by bone mineral density and were separated into four experimental groups with six humeri in each: PHN bending, LCP-PH bending, PHN torsion, or LCP-PH torsion. Comminuted fractures of the surgical neck were simulated by excising a 10-mm wedge of bone. Bending specimens were cyclically loaded from 0 to 7.5 Nm of varus bending moment at the fracture site. Torsion specimens were cyclically loaded to ±2 Nm of axial torque. The mean and maximum displacement in bending, mean and maximum angular rotation in torsion, and stiffness of the bone-implant constructs were compared. Results: In bending, the LCP-PH group demonstrated significantly less mean displacement of the distal fragment than did the PHN group over 5000 cycles (p = 0.002). In torsion, the LCP-PH group demonstrated significantly less mean angular rotation than did the PHN group over 5000 cycles (p = 0.04). A significant number of specimens in the PHN group failed prior to reaching 5000 cycles (p = 0.04). The LCP-PH implant created a significantly stiffer bone-implant construct than did the PHN implant (p = 0.007). Conclusions: The LCP proximal humeral plate demonstrated superior biomechanical characteristics compared with the proximal humeral nail when tested cyclically in both cantilevered varus bending and torsion. The rate of early failure of the proximal humeral nail could reflect the high moment transmitted to the locking proximal screw-bone interface in this implant. Clinical Relevance: The high failure rate in torsion of the proximal humeral nail-bone construct is concerning, and, with relatively osteoporotic bone and early motion, the results could be poor.
ACCESSION #
22449156

 

Related Articles

  • Fatigue failure of an AO spiral blade. Syed, A. A.; Kennedy, J. G.; Mullett, H.; O'Flanagan, J.; Taylor, D. // Archives of Orthopaedic & Trauma Surgery;May2000, Vol. 120 Issue 5/6, p366 

    We report an unusual case of a femoral neck stress fracture leading to the fatigue failure of an AO spiral blade. An unreamed femoral nail with a spiral blade was inserted to treat an unstable subtrochanteric femoral fracture, which lead to fracture union at 5 months. Eight months...

  • Bone Loss Following Tibial Osteotomy: A Model for Evaluating Post-traumatic Osteopenia. Karlsson, M. K.; Josefsson, P.-O.; Nordkvist, A.; Akesson, K.; Seeman, E.; Obrant, K. J. // Osteoporosis International;Mar2000, Vol. 11 Issue 3, p261 

    : The reduced bone mineral density (BMD) found in patients with fractures may, in part, follow rather than precede the fracture. We studied the magnitude and reversibility of bone loss in the 15 months following osteotomy in 21 men and 5 women with localized medial arthritis of the knee. BMD...

  • Effects of risedronate on fracture risk in postmenopausal women with osteopenia. Siris, E.S.; Simon, J.A.; Barton, I.P.; McClung, M.R.; Grauer, A. // Osteoporosis International;May2008, Vol. 19 Issue 5, p681 

    This posthoc analysis of four trials studied the efficacy of risedronate to reduce fragility fractures in postmenopausal women with osteopenia (i.e., T-scores between −1 and −2.5). Risedronate reduced the fracture risk by 73% ( p = 0.023) in this population of women with low femoral...

  • fracture. Peters, Michael // BMA A-Z Family Medical Encyclopedia;2004, p322 

    A definition of the term "fracture" is presented. It refers to a break in a bone, which occurs most often across the width of a bone, but can be lengthwise, oblique, or spiral. Fractures can either be closed, in which the broken bone ends remain beneath the skin and little of the surrounding...

  • Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble? Krastman, Patrick; Bent, Rob; Krijnen, Pieta; Schipper, Inger // Archives of Orthopaedic & Trauma Surgery;Jun2006, Vol. 126 Issue 5, p297 

    Introduction: Undisplaced intracapsular fractures are predominantly treated with a minimally invasive fixation technique, whereas the standard treatment for displaced intracapsular fractures is still a subject of discussion. The purpose of this study was to identify the determinants influencing...

  • OPEN REDUCTION AND STABLE FIXATION OF ISOLATED, DISPLACED TALAR NECK AND BODY FRACTURES. Lindvall, Eric; Haidukewych, George; DiPasquale, Thomas; Herscovici Jr., Dolfi; Sanders, Roy // Journal of Bone & Joint Surgery, American Volume;Oct2004, Vol. 86-A Issue 10, p2229 

    Background: The purpose of this retrospective review was to evaluate the long-term results of surgical treatment of isolated, displaced talar neck and/or body fractures with stable internal fixation. Methods: The study included twenty-five patients with a total of twenty-six displaced fractures...

  • Ipsilateral fracture of the femoral neck and shaft, treatment by reconstruction interlocking nail. Hossam ElShafie, M.; Adel Morsey, H.; Emad Eid, Y. // Archives of Orthopaedic & Trauma Surgery;Jan2001, Vol. 121 Issue 1/2, p71 

    This study involved nine patients with ipsilateral fractures of the neck and shaft of the femur. They were all male with an average age of 28.5 years. All of the fractures resulted from high-energy trauma. The neck fracture was initially missed in one case. All fractures were fixed by a...

  • Improving osteoporosis management in patients with fractures. Johnson, S. I.; Petkov, V. I.; Williams, M. I.; Via, P. S.; Adler, Robert A. // Osteoporosis International;Sep2005, Vol. 16 Issue 9, p1079 

    A history of fracture is an independent risk factor for future fractures, but patients who have sustained a fracture are rarely evaluated for osteoporosis (OP). The objective of this study was to determine if a simple intervention in a general orthopedic clinic would lead to more fracture...

  • Surgical Treatment of Talar Neck Fractures: Evaluation of Results. Tyllianakis, Minos; Karageorgos, Athanasios; Papadopoulos, Andreas Xristou; Lambiris, Elias // European Journal of Trauma;Apr2004, Vol. 30 Issue 2, p98 

    Background:. Consideration of gravity of talar neck fractures and evaluation of the treatment results. Patients and Methods:. 22 patients suffering from talar neck fractures were retrospectively reviewed. There were ten type A, six type B, three type C, and three type D fractures according to...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics