TITLE

HIGH PLACEMENT OF NONCEMENTED ACETABULAR COMPONENTS IN REVISION TOTAL HIP ARTHROPLASTY

AUTHOR(S)
Hendricks, Kelly J.; Harris, William H.
PUB. DATE
October 2006
SOURCE
Journal of Bone & Joint Surgery, American Volume;Oct2006, Vol. 88-A Issue 10, p2231
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We previously reported the average ten-year results associated with the use of porous-coated noncemented acetabular shells that were placed at a high hip center at the time of revision total hip arthroplasty in thirty-four patients (thirty-six hips) with severe acetabular bone loss. We now report the average 16.8-year results for twenty-one patients (twenty-three hips). Of the original cohort of forty-four patients (forty-six hips), thirty-nine patients (forty-one hips; 89%) retained the shell. Two shells (4.3%) were revised because of aseptic loosening, and three (6.5%) were revised because of infection. Six femoral components were revised because of femoral osteolysis, and seven were revised because of aseptic loosening without osteolysis. On the basis of our results after an average duration of follow-up of 16.8 years, we believe that the placement of an uncemented acetabular component at a high hip center continues to be an excellent technique for revision total hip arthroplasty in selected patients with severe acetabular bone loss.
ACCESSION #
22449152

 

Related Articles

  • Therapeutic effect of transtrochanteric rotational osteotomy and hip arthroplasty on quality of life of patients with osteonecrosis. Nakai, T.; Masuhara, K.; Matsui, M.; Ohzono, K.; Ochi, T. // Archives of Orthopaedic & Trauma Surgery;May2000, Vol. 120 Issue 5/6, p252 

    We reviewed 37 patients with avascular necrosis of the femoral head (ANF). There were 23 men and 14 women with a mean age of 36 years at the time of the operation. The duration of follow-up was 9 years. Twenty patients had undergone transtrochanteric rotational osteotomy (TRO) and 17, hip...

  • Fifteen-year results of the Müller CoCrNiMo Straight Stem. Räber, Dieter A.; Czaja, Stephan; Morscher, Erwin W. // Archives of Orthopaedic & Trauma Surgery;Jan2001, Vol. 121 Issue 1/2, p38 

    Between September 1980 and May 1982, 112 primary unilateral total hip arthroplasties with the original cemented M. E. Müller Straight stem (manufactured from Protasul-10, a CoCrNiMo alloy) were inserted in 109 consecutive patients, all combined with non-cemented, non-coated polyethylene RM...

  • Revision total hip arthroplasty using the Zweymuller femoral stem. Matthew Oetgen; Michael Huo // Journal of Orthopaedics & Traumatology;Jun2008, Vol. 9 Issue 2, p57 

    Abstract Background  A variety of femoral stem designs have been reported to be successful in revision total hip arthroplasty without consensus as to optimal design. We evaluated the clinical and radiographic outcomes in a consecutive series of femoral revisions using a wedge-shape,...

  • The Artek cup for total hip replacement of dysplastic hip joints. Schöllner, Carsten // Archives of Orthopaedic & Trauma Surgery;Jul2003, Vol. 123 Issue 6, p299 

    Background. One specific difficulty in total hip replacement for developmental dysplasia of the hip is a shallow acetabulum with a short anteroposterior diameter. In a prospective cohort study we investigated the short-term results of the Artek cup, designed with a shallow outline and a...

  • Posterior Capsular Repair Following Total Hip Arthroplasty: A Modified Technique. Osmani, Omar; Malkani, Arthur; Harwin, Steven F. // Orthopedics;Jun2004, Vol. 27 Issue 6, p553 

    The article presents a modified technique of exposing and repairing the posterior structure during total hip arthroplasty. Studies have demonstrated the merits of posterior capsular repair with respect to decreasing the incidence of dislocation. The technique offers excellent fixation of the hip...

  • Revision total hip arthroplasty using the Zweymuller femoral stem. Matthew Oetgen; Michael Huo // Journal of Orthopaedics & Traumatology;Jun2008, Vol. 9 Issue 2, p57 

    Abstract Background  A variety of femoral stem designs have been reported to be successful in revision total hip arthroplasty without consensus as to optimal design. We evaluated the clinical and radiographic outcomes in a consecutive series of femoral revisions using a wedge-shape,...

  • Pain after total hip arthroplasty: a psychiatric point of view. Pacault-Legendre, V.; Anract, P.; Mathieu, M.; Courpied, J. // International Orthopaedics;Feb2009, Vol. 33 Issue 1, p65 

    After total hip arthroplasty (THA), many studies report that a small percentage of patients mention painful symptoms, whose origin remains more or less obscure. We investigated 1,000 patients who had undergone a THA at least one year before their inclusion in the survey protocol. Among these...

  • Intraoperative Periprosthetic Fractures During Total Hip Arthroplasty. Davidson, Darin; Pike, Jeffrey; Garbuz, Donald; Duncan, Clive P.; Masri, Bassam A. // Journal of Bone & Joint Surgery, American Volume;Sep2008, Vol. 90-A Issue 9, p2000 

    The article presents an overview of an increase in intraoperative periprosthetic fractures which have been seen during total hip arthroplasty procedures. A discussion of the risk factors for intraoperative periprosthetic fractures, including the use of minimally invasive techniques, is...

  • Revision hip arthroplasty in a patient with a hip rotationplasty (type B III b). Gosheger, G.; Hillmann, A.; Ozaki, T.; Bertsch, C.; Winkelmann, W. // Archives of Orthopaedic & Trauma Surgery;Mar2002, Vol. 122 Issue 3, p186 

    We report for the first time a patient who underwent a revision hip arthroplasty after a hip rotationplasty (Winkelmann type B III b) because of a chondrosarcoma in 1988. The clinical symptoms and radiographic findings (X-ray, bone scintigraphy, arthrography) of the aseptic loosening of the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics