TITLE

Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy

AUTHOR(S)
Kaushik, Sushmita; Jain, Rajeev; Pandav, Surinder Singh; Gupta, Amod
PUB. DATE
September 2006
SOURCE
Indian Journal of Ophthalmology;Sep2006, Vol. 54 Issue 3, p159
SOURCE TYPE
Academic Journal
DOC. TYPE
journal article
ABSTRACT
Purpose: To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy.Materials and Methods: Participants: Patients with open and closed angles attending a glaucoma clinic were recruited for the study.Observation Procedures: Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer's classification. These angles were quantified by ultrasound biomicroscopy (UBM) using the following biometric characteristics: Angle opening distance at 250 micro (AOD 250) and 500 micro (AOD 500) from the scleral spur and trabecular meshwork-ciliary process distance (TCPD). The angles were further segregated as "narrow angles" (Schaffer's Grade 2 or less) and "open angles" (Schaffer's Grade 3 and 4).Main Outcome Measures: The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation.Results: One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy (P < 0.001). The Pearson correlation coefficient between all UBM parameters and gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58+/-49 micro, 102+/-84 micro and 653+/-124 respectively, while it was 176+/-47 micro, 291+/-62 micro and 883+/-94 micro in eyes with open angles (P < 0.001) respectively.Conclusions: The angle width estimated by gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.
ACCESSION #
22124413

 

Related Articles

  • Ultrasound Biomicroscopy in Glaucoma. Kaushik, Sushmita; Pandav, Surinder Singh // Journal of Current Glaucoma Practice;May-Aug2010, Vol. 4 Issue 2, p77 

    The advent of the ultrasound biomicroscope (UBM) has made high resolution imaging of the anterior segment possible, permitting reproducible imaging of the cross-sectional anterior chamber angle anatomy. This article gives an outline of normal angle anatomy, technique of UBM and reviews the...

  • Ultrasound biomicroscopy of Chinese eyes with iridocorneal endothelial syndrome. Zhang, M.; Chen, J.; Liang, L.; Laties, A. M.; Liu, Z. // British Journal of Ophthalmology;Jan2006, Vol. 90 Issue 1, p64 

    Aim: To document the ultrasound biomicroscopic (UBM) findings in Chinese patients with iridocorneal endothelial (ICE) syndrome. Methods: 21 patients with ICE syndrome and 15 normal subjects underwent UBM. UBM findings of anterior segment were compared between normal subjects and three clinical...

  • Comparison of ultrasound biomicroscopic parameters after laser iridotomy in eyes with primary angle closure and primary angle closure glaucoma. Dada, T.; Mohan, S.; Sihota, R.; Gupta, R.; Gupta, V.; Pandey, R. M. // Eye;Jul2007, Vol. 21 Issue 7, p956 

    Purpose: To study changes in anterior segment morphology after laser peripheral iridotomy (LPI) in primary angle closure (PAC) and primary angle closure glaucoma (PACG) using ultrasound biomicroscopy (UBM). Methods: Ninety-three eyes of 93 patients underwent anterior...

  • Brown deposits in the optic of foldable intraocular lenses in patients with uveitis. Manuchehri, K.; Mohamed, S.; Cheung, D.; Saeed, T.; Murray, P. I. // Eye;Jan2004, Vol. 18 Issue 1, p54 

    PURPOSE: To report a new finding of brown deposits scattered in the substance of the optic of foldable intraocular lenses (IOL) following phakoemulsification in patients with uveitis. METHODS: Consecutive uveitis patients (54 patients, 71 eyes) who had undergone phakoemulsification with a...

  • SLIT-LAMP BIOMICROSCOPY  // Davis's Comprehensive Handbook of Laboratory & Diagnostic Tests ;Jan2006, p1182 

    This noninvasive procedure is used to visualize the anterior portion of the eye and its parts, including the eyelids and eyelashes, sclera, conjunctiva, cornea, iris, lens, and anterior chamber, and to detect pathology of any of these areas of the eyes. The slit lamp has a binocular microscope...

  • Spontaneous resolution of a rare case of circumferential lymphangiectasia haemorrhagica conjunctivae. Huerva, V; Traveset, A E; Ascaso, F J; S├ínchez, M C // Eye;Jul2014, Vol. 28 Issue 7, p912 

    The article presents a case study of a 36-year-old woman who complained of spontaneous ocular redness and swelling in her right eye. A circumferential engorgement of the bulbar conjunctival vessels, which appeared as worm-like conjunctival lymph vessels filled with blood, has been revealed with...

  • Ultrasound Biomicroscopy of Eyelid Lymphangioma in a Child. Horgan, Noel; Shields, Carol L.; Minzter, Ronald; Shields, Jerry A. // Journal of Pediatric Ophthalmology & Strabismus;Jan/Feb2008, Vol. 45 Issue 1, p55 

    A 13-month-old girl developed a superficial, multinodular, blue-grey upper eyelid mass shortly after birth. This was clinically suspected to be a lymphangioma. Ultrasound biomicroscopy revealed a subcutaneous mass with a multicystic internal structure and fluid levels consistent with...

  • Evaluating clinical signs in trabeculectomized eyes. Crowston, J. G.; Kirwan, J. F.; Wells, A.; Kennedy, C.; Murdoch, I. E. // Eye;Mar2004, Vol. 18 Issue 3, p299 

    Aim To evaluate interobserver agreement for clinical signs in trabeculectomized eyes when examined face-to-face with slit-lamp biomicroscopy (SL) or by remote examination using telemedicine (real-time remote video imaging; TM). Method A system for examining trabeculectomized eyes was devised and...

  • slit-lamp. Peters, Michael // BMA A-Z Family Medical Encyclopedia;2004, p698 

    An encyclopedia entry for "slit-lamp" is presented. It is an illuminated type of microscope used to examine the internal structures of the front part of the eye. It may also be used to view the retina at the back of the eye.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.