TITLE

METHODS USED TO PROCESS DATA FROM INDIRECT CALORIMETRY AND THEIR APPLICATION TO VO2MAX

AUTHOR(S)
Robergs, Robert A.; Burnett, Angus F.
PUB. DATE
May 2003
SOURCE
Journal of Exercise Physiology Online;May2003, Vol. 6 Issue 2, p44
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Our purpose was to provide objective evidence in support of recommendations for how to process data in gas exchange indirect calorimetry (GEIC). A computer generated data set, devoid of biological variability and measurement error, was used to assess the error in data processing methods of a) 0.25, 0.5 and 1.0 min time averages, b) a 7 breath average, and c) a 11 breath smoothing (moving average) function. We aligned averaged data to the end and center of the time interval, and also used a breath-by-breath data set from an incremental exercise test to volitional fatigue to show the results of data processing using real data. Aligning time averaged data to the end of the interval under-estimated oxygen consumption (VO2) (mean±SD, mL/min) by 29.99±5.21 (0.25 min end), 65.09±6.40 (0.5 min end), and 134.20±3.48 (1 min end). Aligning time averaged data to the center of the interval resulted in slight over-estimation of VO2, with mean±SD (mL/min) errors of -12.61±5.10 (1.0 min), - 5.94±3.43 9 (0.5 min), and -3.41±4.01 (0.25 min). Results from the 7 breath averaged data revealed monoexponential decreases in error with increases in VO2, ranging from (rest to peak VO2, mL/min) 67.93 to 11.8 and 0.47 to 0.01, for end and center aligned data, respectively. Smoothing (11 breath) also resulted in monoexponential decreases in error with increases in VO2, with a range of residuals from (rest to peak VO2) 1.08 to 0.03 mL/min. Similar procedures were applied to examples of breath-by-breath data obtained from research subjects, and therefore data containing biological variability. In addition, data processing involving interpolation and filtering was applied to the human subjects acquired data. Averaging VO2 data from GEIC across 0.5 and 1.0 min time intervals adds to the total error of measurement in GEIC. Where possible, data averaging should occur by breath averaging (~7 breaths) aligned to the center of the interval. Data processing of breath-by-breath data using interpolation and filtering has potential, and required further research to assess validity.
ACCESSION #
21794702

 

Related Articles

  • Indirect calorimetry during non invasive mechanical ventilation. Is the next step for gas exchange monitoring? Esquinas, Antonio; Koksal, Güniz // Journal of Clinical Monitoring & Computing;Feb2013, Vol. 27 Issue 1, p99 

    We analyze validation and some technical aspects of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation (NIMV). This validation study assess the reliability of gas exchange measurement with indirect calorimetry...

  • In vitro validation of a metabolic monitor for gas exchange measurements in ventilated neonates. Behrends, M.; Kernbach, M.; Bräuer, A.; Braun, U.; Peters, J.; Weyland, W.; Bräuer, A // Intensive Care Medicine;Jan2001, Vol. 27 Issue 1, p228 

    Objective: To evaluate the Datex Deltatrac II for measurements in neonates requiring mechanical ventilation. Design: Prospective laboratory evaluation, using a ventilated lung model and gas injection. During simulation of 79 neonatal respiratory settings, assessment of oxygen consumption (VO2),...

  • THE PHYSIOLOGICAL MECHANISM BEHIND THE TALK TEST. Creemers, Noortje; Foster, Carl; Porcari, John P.; Cress, Maria L.; de Koning, Jos J. // Kinesiology;June2017, Vol. 49 Issue 1, p3 

    The Talk Test (TT) is a very simple marker of exercise intensity, which has been shown to be a useful surrogate of the ventilatory (VT) and respiratory compensation (RCT) thresholds. The purpose of this study was to evaluate a potential mechanism behind the TT. Healthy, college-aged subjects...

  • Impact of Overweight and Pneumoperitoneum on Hemodynamics and Oxygenation during Prolonged Laparoscopic Surgery. Meininger, Dirk; Zwissler, Bernhard; Byhahn, Christian; Probst, Michael; Westphal, Klaus; Bremerich, Dorothee // World Journal of Surgery;Apr2006, Vol. 30 Issue 4, p520 

    Background: Anesthesia adversely affects respiratory function and hemodynamics in obese patients. Although many studies have been performed in morbidly obese patients, data are limited concerning overweight patients [BMI 25–29.9 kg m-2]. The aim of this study was to evaluate the effects...

  • Standardized estimation of external respiration function. G. Shishkin; N. Ustyuzhaninova; N. Umantseva // Human Physiology;Feb2007, Vol. 33 Issue 1, p125 

    Abstract??External respiration in healthy males has, in addition to eupnea, six functionally active variants with one or several indices deviating from the normal values. Hyperpnea and hypopnea are determined by deviations in general oxygen consumption accompanied by adequate changes in...

  • Assessment of breath-by-breath alveolar gas exchange: an alternative view of the respiratory cycle. Cettolo, V.; Francescato, Maria // European Journal of Applied Physiology;Sep2015, Vol. 115 Issue 9, p1897 

    Purpose: Breath-by-breath (BbB) determination of the O flux at alveolar level implies the identification of the start and end points of each respiratory cycle; Grønlund defined them as the times in two successive breaths showing equal expiratory gas fractions. Alternatively, the start and end...

  • Validity of Reporting Oxygen Uptake Efficiency Slope from Submaximal Exercise Using Respiratory Exchange Ratio as Secondary Criterion. Williamson, Wilby; Fuld, Jonathan; Westgate, Kate; Sylvester, Karl; Ekelund, Ulf; Brage, Soren // Pulmonary Medicine;2012, p1 

    Background. Oxygen uptake efficiency slope (OUES) is a reproducible, objective marker of cardiopulmonary function. OUES is reported as being relatively independent of exercise intensity. Practical guidance and criteria for reporting OUES from submaximal tests has not been established. Objective....

  • A new interpolation-free procedure for breath-by-breath analysis of oxygen uptake in exercise transients. Bringard, Aurélien; Adami, Alessandra; Moia, Christian; Ferretti, Guido // European Journal of Applied Physiology;Sep2014, Vol. 114 Issue 9, p1983 

    Introduction: Interpolation methods circumvent poor time resolution of breath-by-breath oxygen uptake ( $$\dot{V}{\text{O}}_{2}$$ ) kinetics at exercise onset. We report an interpolation-free approach to the improvement of poor time resolution in the analysis of $$\dot{V}{\text{O}}_{2}$$...

  • Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch. Lockwood, Geoffrey; Fung, Nick; Jones, J. // Journal of Clinical Monitoring & Computing;Dec2014, Vol. 28 Issue 6, p581 

    We describe a three-compartment model (shunt and two perfused compartments) to analyse the relationship between inspired oxygen (FO) and arterial oxygen saturation (SO) in terms of pulmonary shunt and ventilation-perfusion ratio (V/Q). The program was tested using 24 exact datasets, each with...