TITLE

New interface plate for microspray ionization mass spectrometry

AUTHOR(S)
Li Zhou; Lailiang Zhai; Bingfang Yue; Lee, Edgar D.; Lee, Milton L.
PUB. DATE
August 2006
SOURCE
Analytical & Bioanalytical Chemistry;Aug2006, Vol. 385 Issue 6, p1087
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A new interface plate was employed in microspray ionization mass spectrometry (μESI-MS) to improve ion transmission from the sprayer into the sampling nozzle of the mass spectrometer at atmospheric pressure. Using a time-of-flight mass spectrometer (TOFMS), a fivefold increase in ion intensity and a sevenfold reduction in method detection limit were observed. The interface plate attenuated the dependence of the ion intensity on the sprayer position. Even when the distance between the sprayer tip and sampling nozzle was 15.0 mm, ion signals were still stronger than when the sprayer tip was positioned 3.0 mm in front of the sampling nozzle with the original interface plate. This enhancement in the performance of μESI-MS was due to the improved shapes of the equipotential lines near the sprayer tip and the long desolvation distance between the sprayer and the sampling nozzle of the MS.
ACCESSION #
21396821

 

Related Articles

  • Nanomaterials in mass spectrometry ionization and prospects for biological application. Zhong Guo; Ganawi, Amel A. A.; Qiang Liu; Lin He // Analytical & Bioanalytical Chemistry;Jan2006, Vol. 384 Issue 3, p584 

    The rapid development of nanotechnology has revolutionized scientific developments in recent decades. Mass spectrometry (MS) measurements are no exception and have benefited greatly from integration of nanomaterials in every step of analysis. This brief review summarizes recent developments in...

  • Nanoelectrospray ion generation for high-throughput mass spectrometry using a micromachined ultrasonic ejector array. Aderogba, S.; Meacham, J. M.; Degertekin, F. L.; Fedorov, A. G.; Fernandez, F. M. // Applied Physics Letters;5/16/2005, Vol. 86 Issue 20, p203110 

    Ultrasonic electrospray ionization (ESI) for high-throughput mass spectrometry is demonstrated using a silicon micromachined microarray. The device uses a micromachined ultrasonic atomizer operating in the 900 kHz–2.5 MHz range for droplet generation and a metal electrode in the fluid...

  • The secret of NIMS. Doerr, Allison // Nature Methods;Dec2007, Vol. 4 Issue 12, p985 

    A new mass spectrometry surface-based ionization method offers up advantages in sensitivity and the ability to directly analyze biological samples, especially for metabolomics studies.

  • Conceptual Study on New Isotope Analysis Technique with Resonance Ionization Mass Spectrometry Using Inductively Coupled Plasma as an Atomic Source (ICP-RIMS). Watanabe, K.; Higuchi, Y.; Tomita, H.; Kawarabayashi, J.; Uritani, A.; Iguchi, T. // AIP Conference Proceedings;3/17/2009, Vol. 1104 Issue 1, p108 

    We have proposed the novel isotope analysis technique with Resonance Ionization Mass Spectrometry using Inductively Coupled Plasma as an atomic source (ICP-RIMS). Each component of ICP-RIMS is conceptually designed. We conclude that the orthogonal acceleration time-of-flight mass spectrometer...

  • Mass spectrometric studies of laser ablated plume from a superconducting material. Saleem, M.; Hameed, A.; Iqbal, M. J.; Baig, M. A. // European Physical Journal D -- Atoms, Molecules, Clusters & Opti;Feb2010, Vol. 55 Issue 1, p121 

    The ionic species present in the laser ablated plume from the surface of the Bi1.6Pb0.4Sr2Ca2Cu3Oysuperconducting target have been investigated using a non-commercial laboratory developed linear time-of-flight (TOF) mass spectrometer. The recorded TOF mass spectra reveal the presence of all the...

  • Mass spectrometer gets tough on terrorism.  // Machine Design;5/25/2006, Vol. 78 Issue 10, p44 

    Reports on the development of a battery-powered mass spectrometer to fight terrorism. Prototypes of handheld instruments for the detection of triacetone triperoxide; Efficiency of mass spectrometry in the transformation of molecules to ions; Ionization of samples through the desorption...

  • Overcoming spectral overlap in isotopic analysis via single- and multi-collector ICP–mass spectrometry. Vanhaecke, Frank; Luc Moens // Analytical & Bioanalytical Chemistry;Jan2004, Vol. 378 Issue 2, p232 

    For isotope ratio applications where an internal isotope ratio precision >0.05–0.1% relative standard deviation suffices, single-collector inductively coupled plasma mass spectrometry (ICPMS) is fit-for-purpose, but for detecting more subtle variations in the natural isotopic composition...

  • A binary matrix for background suppression in MALDI-MS of small molecules. Zhong Guo; Lin He // Analytical & Bioanalytical Chemistry;Mar2007, Vol. 387 Issue 5, p1939 

    Application of matrix-assisted laser-desorption ionization mass spectrometry (MALDI-MS) to small-molecule detection is often limited, because of high matrix background signals in the low-mass region. We report here an approach in which a mixture of two conventional MALDI matrices with different...

  • Study of the carbonyl products of terpene/OH radical reactions: detection of the 2,4-DNPH derivatives by HPLC-MS. Van den Bergh, Viviane; Coeckelberghs, Hans; Vankerckhoven, Hans; Compernolle, Frans; Vinckier, Chris // Analytical & Bioanalytical Chemistry;Jun2004, Vol. 379 Issue 3, p484 

    The oxidation of the terpenes α- and β-pinene, limonene and Δ3-carene by hydroxyl radicals has been investigated in a fast-flow reactor coupled to a liquid nitrogen trap for collecting the carbonyl compounds. Identification of the products was performed via 2,4-dinitrophenylhydrazone...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library