TITLE

Vanadium determination in chloride matrices using ICP-MS: finding the optimum collision/reaction cell parameters for suppressing polyatomic interferences

AUTHOR(S)
Chrastný, Vladislav; Komárek, Michael; Mihaljevič, Martin; Štíchová, Jana
PUB. DATE
August 2006
SOURCE
Analytical & Bioanalytical Chemistry;Aug2006, Vol. 385 Issue 5, p962
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Efficiencies of He/NH3 and He/H2 collision gases were compared in a conventional type of hexapole cell of an inductively coupled plasma mass spectrometer (ICP-MS). The optimum conditions [hexapole and quadrupole bias voltage (VH and VQ) and collision/reaction gas flow rates] were tested for vanadium determination (51V) in chloride matrices. When the He/H2 mixture was used, the optimum values of VH and VQ were −10.0 and −8.0 V, respectively. This set-up corresponds to the kinetic energy discrimination effect. When the He/NH3 mixture was used, the optimum values of VH and VQ were +10.0 and −7.0 V, respectively. Positive VH values correspond to the ion kinetic energy effect, which allows the reactivity of the ions entering the collision/reaction cell with the reaction gas to be controlled. The obtained results showed that the He/H2 mixture is not optimal for V determination in samples containing chlorides due to the insufficient suppression of the polyatomic interference of 35Cl16O+. Data obtained from vanadium determination using the He/NH3 mixture were consistent for all selected Cl− concentrations, and the results were acceptable. The detection limit was comparable with detection limits obtained from ICP-MS equipped with a dynamic reaction cell. Analyses of elements forming interfering molecules, e.g., iron (56Fe), arsenic (75As) and selenium (80Se), were in good agreement with the certified values for both studied collision/reaction gas mixtures.
ACCESSION #
21288214

 

Related Articles

  • Battery-powered pulsed high density inductively coupled plasma source for pre-ionization in laboratory astrophysics experiments. Chaplin, Vernon H.; Bellan, Paul M. // Review of Scientific Instruments;Jul2015, Vol. 86 Issue 7, p1 

    An electrically floating radiofrequency (RF) pre-ionization plasma source has been developed to enable neutral gas breakdown at lower pressures and to access new experimental regimes in the Caltech laboratory astrophysics experiments. The source uses a customized 13.56 MHz class D RF power...

  • Experimental setup and electrical characteristics of an inductively coupled plasma. Godyak, V.A.; Piejak, R.B. // Journal of Applied Physics;1/15/1999, Vol. 85 Issue 2, p703 

    Describes an experimental system that has been used to study inductively coupled plasma (ICP). Literature on ICP; Experimental design and methodology; Measurement of radio frequency (rf) power absorbed by plasma; ICP external electrical parameters; Potential rf plasma; Conclusions.

  • Performance of a new nebulizer system for simultaneous determination of Sb, Sn (hydride generation), V, and Zn by ICP�OES. Zoltan, T.; Benzo, Z.; Murillo, M.; Marcano, E.; G�mez, C.; Salas, J.; Quintal, M. // Analytical & Bioanalytical Chemistry;Jul2005, Vol. 382 Issue 6, p1419 

    A new nebulizer system is described that extends the analytical capability of the inductively coupled plasma technique to include the simultaneous determination of two elements Sb and Sn (hydride-forming), with two conventional elements, V and Zn. The main advantage of this system is its...

  • Arsenic and trace metals in commercially important bivalves, Anadara granosa and Paphia undulata. Mat, I. // Bulletin of Environmental Contamination & Toxicology;Jun1994, Vol. 52 Issue 6, p833 

    The article presents a study on the levels of concentration of arsenic and trace metals in bivalve molluscs Anadara granosa and Paphia undulata purchased from retail outlets in Kuala Lumpur, Malaysia. The bivalve samples were homogenized, and analysis of trace metals was performed using Baird...

  • Impact of Group Embryo Culture Strategies on Blastocyst Development. Ouellette, R. // Fertility Weekly;7/22/2013, p3 

    The article offers information on the study conducted by M. S. Bloom and colleagues which examines the single follicular fluid (FF) measurements. A laboratory-developed method for a sector field-inductively coupled plasma-mass spectrometer (SF-ICP-MS) was used to analyze FF specimens for cadmium...

  • Pilot measurements of 237Np in forest litter from Poland. La Rosa, Jerome J.; Mietelski, Jerzy W.; Wyse, Eric // Journal of Radioanalytical & Nuclear Chemistry;Feb2010, Vol. 283 Issue 2, p385 

    Described are results and the procedure for a pilot study on 237Np content in forest litter samples from Poland in relation to their plutonium activity. Neptunium was determined by inductively coupled plasma mass spectrometry (ICP-MS) and Pu by alpha spectrometry. Two samples originated from a...

  • Dynamics of Some Mineral Elements in Sheep Colostrum. Goran, Gheorghe Valentin; Crivineanu, Victor; Rotaru, Elena; Tudoreanu, Liliana; Hanganu, Adina // Bulletin of the University of Agricultural Sciences & Veterinary;2010, Vol. 67 Issue 2, p81 

    Colostrum is the first milk produced by female mammals after birth, and it has a thick consistency and yellowish color, it is very rich in energy, protein, vitamins and minerals. The study main goal was quantitative determination of 22 mineral elements by inductively coupled plasma spectrometry...

  • Design Criteria for ICP Spectrometry Using Advanced Optical and CCD Technology. Mermet, Jean Michel; Cosnier, Agnès; Danthez, Yves; Dubuisson, Cendrine; Fretel, Emmanuel; Rogerieux, Olivier; Vélasquez, Sébastien // Spectroscopy;Feb2005, Vol. 20 Issue 2, p60 

    Presents information on inductively coupled plasma spectrometry detection technology that combines photon-current conversion and a solid-state multichannel detector. Czerny-Turner optical system; Selection of pixel size; CCD detector.

  • ICP emission spectrometers.  // Spectroscopy;Apr2006, Vol. 21 Issue 4, p54 

    The article evaluates iCAP 6300 and 6500 inductively-coupled plasma emission spectrometers from Thermo Electron and offers information on design and key features.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics