TITLE

Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization

AUTHOR(S)
Cannara, Rachel J.; Eglin, Michael; Carpick, Robert W.
PUB. DATE
May 2006
SOURCE
Review of Scientific Instruments;May2006, Vol. 77 Issue 5, p053701
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Proper force calibration is a critical step in atomic and lateral force microscopies (AFM/LFM). The recently published torsional Sader method [C. P. Green et al., Rev. Sci. Instrum. 75, 1988 (2004)] facilitates the calculation of torsional spring constants of rectangular AFM cantilevers by eliminating the need to obtain information or make assumptions regarding the cantilever’s material properties and thickness, both of which are difficult to measure. Complete force calibration of the lateral signal in LFM requires measurement of the lateral signal deflection sensitivity as well. In this article, we introduce a complete lateral force calibration procedure that employs the torsional Sader method and does not require making contact between the tip and any sample. In this method, a colloidal sphere is attached to a “test” cantilever of the same width, but different length and material as the “target” cantilever of interest. The lateral signal sensitivity is calibrated by loading the colloidal sphere laterally against a vertical sidewall. The signal sensitivity for the target cantilever is then corrected for the tip length, total signal strength, and in-plane bending of the cantilevers. We discuss the advantages and disadvantages of this approach in comparison with the other established lateral force calibration techniques, and make a direct comparison with the “wedge” calibration method. The methods agree to within 5%. The propagation of errors is explicitly considered for both methods and the sources of disagreement discussed. Finally, we show that the lateral signal sensitivity is substantially reduced when the laser spot is not centered on the detector.
ACCESSION #
21126310

 

Related Articles

  • Quantitative comparison of three calibration techniques for the lateral force microscope. Cain, Robert G.; Reitsma, Mark G.; Biggs, Simon; Page, Neil W. // Review of Scientific Instruments;Aug2001, Vol. 72 Issue 8 

    The quantitative use of atomic force microscopes in lateral mode for friction measurements has been limited by uncertainty about reliable calibration techniques. This article describes a comparison of three methods that have been proposed for the calibration of the lateral sensitivity of atomic...

  • Lateral force microscope calibration using a modified atomic force microscope cantilever. Reitsma, M. G. // Review of Scientific Instruments;Oct2007, Vol. 78 Issue 10, p106102 

    A proof-of-concept study is presented for a prototype atomic force microscope (AFM) cantilever and associated calibration procedure that provide a path for quantitative friction measurement using a lateral force microscope (LFM). The calibration procedure is based on the method proposed by...

  • Lateral Force Calibration Method Used for Calibration of Atomic Force Microscope. Ekwińska, Magdalena; Rymuza, Zygmunt // Journal of Telecommunications & Information Technology;2009, Vol. 2009 Issue 4, p83 

    Modern heterogeneous micro- and nanostructures usually integrate modules fabricated using various materials and technologies. Moreover, it has to be emphasized that the macro and micro nanoscale material parameters are not the same. For this reason it has become crucial to identify the...

  • Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system. Li, Q.; Kim, K.-S.; Rydberg, A. // Review of Scientific Instruments;Jun2006, Vol. 77 Issue 6, p065105 

    A novel diamagnetic lateral force calibrator (D-LFC) has been developed to directly calibrate atomic force microscope (AFM) cantilever-tip or -bead assemblies. This enables an AFM to accurately measure the lateral forces encountered in friction or biomechanical-testing experiments at a small...

  • Photonic force microscope calibration by thermal noise analysis. Florin, E.-L.; Pralle, A.; Stelzer, E.H.K.; Hörber, J.K.H. // Applied Physics A: Materials Science & Processing;1998, Vol. 66 Issue 7, pS75 

    Abstract. The threes of a photonic force microscope based on optical tweezers are determined using the Boltzmann distribution of thermally driven position fluctuations. As a fundamental method, only a minimum of information about the system is required, i.e. the solution's temperature. This...

  • Calibration of the power-recycled gravitational wave detector, GEO 600. Hewitsona, M.; Grote, H.; Heinzel, G.; Strain, K. A.; Ward, H.; Weiland, U. // Review of Scientific Instruments;Sep2003, Vol. 74 Issue 9, p4184 

    GEO 600 is an interferometric gravitational wave detector which, when completed, will employ a novel, dual-recycled optical scheme allowing its optical response to be tuned over a range of frequencies. The accurate calibration of the sensitivity of GEO to gravitational waves is a critical part...

  • A small size dipole E-field sensor for calibration of field distribution in EMP simulator. Li-hua Shi; Rong-ren Si; Qing Si; Yan-xin Li // Fiber Optic Sensors & Systems;Nov2012, Vol. 26 Issue 11, p10 

    The calibration of field distribution in EMP simulator is discussed. A small size dipole sensor with built-in optic transmitter and fiber-optic output connection is designed to measure field distribution in various points of the EMP simulator. Influence of the dipole sensor to the field...

  • The whole truth and nothing but the truth? Franklin, Bryan // Control Solutions;Jan2003, Vol. 76 Issue 1, p37 

    Provides information on the process of testing flowmeters. Advice on ensuring a flowmeter calibration; Tips on flow measurement accuracy during calibration; Recommendations from flow calibration experts.

  • UK technique measures pH using probes. Bush, Steve // Electronics Weekly;12/1/2004, Issue 2173, p7 

    This article reports that an Oxford professor has developed a technique for measuring pH, the negative log10 of the hydrogen ion concentration in a solution, one of the most commonly used analytical measurements in science. Probes using the technology do not require calibration. The technique,...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics