TITLE

Method for detecting the disconnection of an extracorporeal device using a patient's endogenous electrical voltages

AUTHOR(S)
Ross, E. A.; Briz, C.; Sadleir, R. J.
PUB. DATE
June 2006
SOURCE
Kidney International;Jun2006, Vol. 69 Issue 12, p2274
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Tubing (especially venous) disconnections using pumped devices cause significant hemorrhage, and current monitoring techniques are imperfect because they rely on intraluminal pressure changes. We devised a passive detection method based on a patient's electrical voltages being transmitted via blood tubing to our alarm circuit. As the arterial and venous access sites are in close proximity, the signals are nearly identical during connection, and markedly different with disconnection. We built a prototype and tested it in vitro with saline and during hemodialysis treatments (n=7). The connection status is determined by examining the difference between endogenous voltages in the blood tubing from and to the patient, and when it exceeds a threshold an alarm condition is triggered. We tested for possible confounding by an electrical shunt through the dialyzer and determined that pathway had an impedance approximately three times (>350 kΩ) that of the tubing to the patient. As the roller blood-pump periodically occluded the tubing, the resultant intermittent very high impedance prevented that potential shunting problem and improved the sensitivity of our device. Disconnections were detectable at various bloodline sites (needles, sampling ports, drip chambers). Thus, the circuit's sensors can be placed remotely at the dialysis machine, with electrical continuity to blood made by inexpensive conductive elements at the tubing wall or drip chambers. Appropriate threshold and noise-eliminating circuitry, as well as alarm states that alert the staff and stop the blood pump, make our prototype a promising low-cost safety enhancement.Kidney International (2006) 69, 2274–2277. doi:10.1038/sj.ki.5001508; published online 3 May 2006
ACCESSION #
21091091

 

Related Articles

  • VIRTUAL CHECKUP.  // Technology Review;Jan/Feb2002, Vol. 105 Issue 1, p17 

    Focuses on the medical monitoring system by Loughborough University in Leicestershire, England. Transmission of data from medical equipment; Derivation of signals from electrodes; Digitalization of the system.

  • Take two and boot up in the morning. Russelburg, Kevin // Design News;2/26/2001, Vol. 57 Issue 4, p56 

    Talks about the developments in Internet- and intranet-connected medical devices. Innovations that will provide real-time body monitoring; One of the biggest advantages of the developments from a medical standpoint.

  • Priming, Connecting, and Disconnecting.  // Indian Journal of Nephrology;Dec2012 Supplement, Vol. 22 Issue 7, pS20 

    The article provides suggestions for correct catheter priming, connecting, and disconnecting during dialysis. It mentions that complications can develop as a result of incorrect connection and disconnection of a patient from the extracorporeal circuit; strict adherence to a protocol and the use...

  • Effects of dialyzer reuse on dialysis adequacy, anemia control, erythropoieting-stimulating agents use and phosphate level. Malyszko, Jolanta; Milkowski, Andrzej; Benedyk-Lorens, Ewa; Dryl-Rydzynska, Teresa // Archives of Medical Science;Feb2016, Vol. 12 Issue 1, p219 

    A letter to the editor is presented regarding the study which focuses on the impact of the reuse of dialyzer on the adequacy of dialysis, anemia control, and erythropoieting-stimulating agents (ESA).

  • Smart Home Care. Voss, David // Technology Review;Sep2001, Vol. 104 Issue 7, p31 

    Reports on diagnostic and home medical devices developed by several companies. Factors that push companies to develop remote sensing technology for health-care and lifestyle monitoring; Early detection; Inexpensive and consumer-friendly devices; Smart medical devices launched by various companies.

  • Sensaris seeks certification for ZAO monitor.  // Medical Device Daily;3/27/2013, Vol. 17 Issue 59, p7 

    This article reports that a multi-sensor device for monitoring vital signs, called ZAO, developed by Sensaris, is going through the certification process and will be available in mid-2013.

  • Death Due to Overheated Dialysate During Dialysis. Fortner, Robert W.; Nowakowski, Andrew; Carter, Charles B.; King Jr., Leroy H.; Knepshield, James H. // Annals of Internal Medicine;Sep70, Vol. 73 Issue 3, p443 

    Presents a case study on a patient who died during hemodialysis with the Travenol recirculating single-pass dialyzer after exposure of extracorporeal blood to overheated dialysate. Background on the case study; Discussion on the case report.

  • Dialyzers associated with thrombocytopenia during hemodialysis treatment.  // Hem/Onc Today;11/10/2011, Vol. 12 Issue 21, p19 

    The article reports that a cohort study of patients from two provinces in Canada has revealed that patients undergoing hemodialysis with electron beam-sterilized dialyzers have an increased risk for thrombocytopenia.

  • Clinical performance characteristics of hemodialysis graft monitoring. Mcdougal, Grant; Agarwal, Rajiv // Kidney International;Aug2001, Vol. 60 Issue 2, p762 

    Clinical performance characteristics of hemodialysis graft monitoring. Background. Regular monitoring of dialysis grafts is recommended, but the value of dialysis graft blood flow monitoring and venous pressures in predicting subsequent outcomes are controversial. Methods. Over a period of one...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics