TITLE

Validation of the Barraquer Tonometer for High Intraocular Pressure Estimation

AUTHOR(S)
Espana, Edgar M.; Acosta, Ana C.; Nose, Izuru; Orozco, Marcia; Fantes, Francisco; Yoo, Sonia H.; Parel, Jean-Marie
PUB. DATE
June 2006
SOURCE
Journal of Refractive Surgery;Jun2006, Vol. 22 Issue 6, p580
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
PURPOSE: To compare the pneumatonometer and the Tono-Pen XL in a closed ex-vivo system in human eye bank eyes at high intraocular pressures (IOP) and evaluate the validity of high IOP measurements with the Barraquer tonometer. METHODS: Intraocular pressure was monitored by cannulation of the anterior chamber and vitreous cavity in eight human cadaver eyes (mean donor age: 77.3±4.9 years, range: 72 to 84 years). Intraocular pressure measurements were taken at 50, 65, and 90 mmHg with the Tono-Pen XL and pneumatonometer. Intraocular pressure was raised to 110 mmHg and then the eyes were deflated slowly until they reached 50 mmHg. Pressure readings with the Barraquer tonometer were recorded when the corneal tonometer interface reached the inner and outer rings. RESULTS: The Tono-Pen XL underestimated IOP, a tendency that was more evident at higher IOP. In contrast, the pneumatonometer was more accurate and reliable at IOP of 50 and 65 mmHg but its readings underestimated IOP at 90 mmHg. The Barraquer tonometer used in this experiment accurately estimated high IOP. A variability of 5.9 mmHg and 5.8 mmHg were recorded for the inner and outer ring, respectively. CONCLUSIONS: The Tono-pen XL is an inadequate instrument to assess pressures normally encountered during LASIK flap creation in an ex vivo model using human cadaver eyes. The pneumatonometer and the Barraquer tonometer are accurate instruments at high IOP; however, the pneumatonometer underestimated pressures around 90 mmHg.
ACCESSION #
21082017

 

Related Articles

  • New Products and Services.  // Ophthalmology Times;08/01/99, Vol. 24 Issue 15, p28 

    Presents products and services for eye care and surgery. Features of the Whittingham UltraClean Phaco Handpiece from Inventive Systems Inc.; Introduction of the fourth edition of the `Ophthalmic Regulatory Manual' of the American Society of Ophthalmic Administrators.

  • Upgraded Keratometer/Refractor and Auto Refractor.  // Review of Ophthalmology;Apr2000, Vol. 7 Issue 4, p136 

    Features several ophthalmic instruments and products. Includes the KR450 Auto Keratometer/Refractor and AR350 Auto Refractor from Reichert Ophthalmic Instruments; Introduction of E-Dr. Network, a business Web site for the eye care industry; Laser Blood Flowmeter CLBF-100, a system measuring...

  • New products and services.  // Ophthalmology Times;06/01/98, Vol. 23 Issue 11, p62 

    Introduces a variety of ophthalmological instruments and eye care products. Includes the CILOXAN fluoroquinolone ointment from Alcon Laboratories Inc.; DGH Model 5100 combination unit A-scan and pachymeter from DGH Technology Inc.; Titanium PK Motility/Support Pegging System from Integrate...

  • OPHTHALMIC Product Guide.  // Review of Ophthalmology;Feb2013 Product Guide Supplement, p1 

    The article reviews several ophthalmology equipments including Heidelberg Engineering Inc.'s Spectralis MultiColor Imaging, Optos PLC's OptosOCT SLO for scanning laser ophthalmoscopy and Icare USA's Icare Tonometers for measuring intraocular pressure (IOP).

  • New body jewelry targets the sclera.  // Ophthalmology Times;9/1/2004, Vol. 29 Issue 17, p6 

    Features the Eye Jewelry, the newest body abandonment in ophthalmic surgery that targets the sclera that is currently available in the U.S. Implant procedure of the Eye Jewelry; Effect of combination between ophthalmology and cosmetic surgery on patients; Availability of various shapes and sizes...

  • Eye-Q Vision Care Center expands in Selma. Lieberman, Lisa // Business Journal Serving Fresno & the Central San Joaquin Valley;10/8/2004, Issue 323306, p6 

    Discusses the expansion plans of Eye-Q Vision Care Center in Selma, California. Improvements in eye care services; Benefits of the expansion for the community; Advantages of the new location.

  • BY THE NUMBERS.  // Vision Monday;12/17/2007, Vol. 21 Issue 14, p64 

    The article presents statistics on a variety of topics, including the percentage of those who have had an initial vision correction surgery, the percentage of those who said they paid extra for anti-reflective coating because they were told it would prevent reflection from behind, and the...

  • Clinicians report portable rebound tonometer to be accurate, user-friendly. Hasson, Matt // Primary Care Optometry News;Mar2009, Vol. 14 Issue 3, p20 

    The article reports that several studies have confirmed that the iCare tonometer, a portable rebound tonometer from Tiolat Oy, offers safe and accurate intraocular pressure (IOP) measurement.

  • PT 100.  // Review of Optometry;2/15/2012 Product Guide, p20 

    The article offers brief information on the PT 100, a portable non-contact tonometer (NCT) from Reichert Inc.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics