TITLE

Emittance and plasma potential measurements in double-frequency heating mode with the 14 GHz electron cyclotron resonance ion source at the university of Jyvýskylý

AUTHOR(S)
Tarvainen, O.; Suominen, P.; Ropponen, T.; Koivisto, H.
PUB. DATE
March 2006
SOURCE
Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A309
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The performance of electron cyclotron resonance ion sources can be improved through the use of multiple-frequency heating. However, the physical processes leading into enhanced production of highly charged ions are still mainly unknown. This gave us a strong motivation to perform a set of emittance and plasma potential measurements with the 14 GHz electron cyclotron resonance ion source at the university of Jyvýskylý to compare the results obtained in single- and double-frequency heating modes. The measurements were performed with different microwave frequencies and combinations of primary and secondary powers. It was observed that both the emittance of different ion beams and the plasma potential decreased in the single-frequency heating mode as the microwave frequency was increased. The emittance of highly charged ion beams and the plasma potential was slightly lower in double-frequency heating mode than in single-frequency mode with the same source settings and total power.
ACCESSION #
20618147

 

Related Articles

  • Electron cyclotron resonance ion source DECRIS-4 for the U400 cyclotron. Leporis, M.; Bekhterev, V.; Bogomolov, S.; Efremov, A.; Gulbekian, G.; Kostyukhov, Yu.; Lebedev, A.; Loginov, V.; Yazvitsky, N. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A301 

    The electron cyclotron resonance ion source DECRIS-4 has been designed and constructed at the FLNR to be used as a second injector of heavy multiply charged ions for the U-400 cyclotron. After the modification of the injection side this source can be also used as a “charge breeder”...

  • ARTEMIS-B: A room-temperature test electron cyclotron resonance ion source for the National Superconducting Cyclotron Laboratory at Michigan State University. Machicoane, G.; Cole, D.; Ottarson, J.; Stetson, J.; Zavodszky, P. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A322 

    The current scheme for ion-beam injection into the coupled cyclotron accelerator at the NSCL involves the use of two electron cyclotron resonance (ECR) ion sources. The first one is a 6.4 GHz fully superconducting that will be replaced within two years by SUSI, a third generation 18 GHz...

  • Effect of frequency tuning on bremsstrahlung spectra, beam intensity, and shape in the 10 GHz NANOGAN electron cyclotron resonance ion source. Rodrigues, G.; Mal, Kedar; Kumar, Narender; Baskaran, R.; Lakshmy, P. S.; Mathur, Y.; Kumar, P.; Kanjilal, D.; Roy, A. // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    Studies on the effect of the frequency tuning on the bremsstrahlung spectra, beam intensities, and beam shape of various ions have been carried out in the 10 GHz NANOGAN ECR ion source. The warm and cold components of the electrons were found to be directly correlated with beam intensity...

  • New tandem type ion source based on electron cyclotron resonance for universal source of synthesized ion beams. Yushi Kato; Yosuke Kurisu; Dai Nozaki; Keisuke Yano; Daiju Kimura; Sho Kumakura; Youta Imai; Takuya Nishiokada; Fuminobu Sato; Toshiyuki Iida // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    A new tandem type source has been constructed on the basis of electron cyclotron resonance (ECR) plasma for producing synthesized ion beams. We investigate feasibility and hope to realize the device which has wide range operation window in a single device to produce many kinds of ion beams based...

  • Efficiency and transit time studies performed with the electron cyclotron resonance ion source dedicated to the radioactive ion beam production at ISAC/TRIUMF. Jayamanna, K.; Yuan, D.; Ames, F.; Bricault, P.; Baartman, R.; Hanemaayer, V.; Laforge, C.; Mitra, A.; McDonald, M.; McKinnon, J.; Olivo, M.; Schmor, P. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A709 

    An electron cyclotron resonance ion source was developed and installed for radioactive ion beam production from gaseous elements at ISAC/TRIUMF. A single mode resonator was used as the microwave cavity and a small quartz tube (70 times smaller than the cavity itself) was placed in it to define...

  • Review on heavy ion radiotherapy facilities and related ion sources (invited). Kitagawa, A.; Fujita, T.; Muramatsu, M.; Biri, S.; Drentje, A. G. // Review of Scientific Instruments;Feb2010, Vol. 81 Issue 2, p02B909 

    Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four...

  • Improvement of the yield of highly charged ions by a gas-pulsing technique and the current status of the NIRS Penning source. Miyata, Tomohiro; Miyoshi, Tomohiro; Sakuma, Tetsuya; Yamamoto, Mitsugu; Kitagawa, Atsushi; Muramatsu, Masayuki; Sato, Yukio // Review of Scientific Instruments;May2004, Vol. 75 Issue 5, p1863 

    The yields of highly charged ions have been improved by using a gas-pulsing technique in the pulsed Penning-ionized-gauge ion source (PIGIS) in the heavy-ion medical accelerator in Chiba. So far, this pulsed PIGIS has been operated under a low-duty factor (10-2–10-3), in which the gas...

  • Design and Calculations for the New ECRIS at KVI. Kremers, H. R.; Beijers, J. P. M.; Brandenburg, S.; Formanoy, I.; Mulder, J.; Sijbring, J.; Koivisto, H.; Rantilla, K. // AIP Conference Proceedings;2005, Vol. 749 Issue 1, p175 

    In this paper a brief description is given of the on-going upgrade of the CAPRICE-type ECRIS injector of the K=600 AGOR cyclotron at KVI. This upgrade is motivated by the new TRIμP program, which requires a significant increase of available beam intensity by up to two orders in magnitude. The...

  • The injection efficiency measurement and analysis for central region model cyclotron. Hongjuan Yao; Zhenguo Li; Tao Ge; Longcheng Wu; Fengping Guan; Yinlong Lv; Zhenhui Wang; Gengshou Liu; Tianjue Zhang; Hongru Cai // Review of Scientific Instruments;Feb2010, Vol. 81 Issue 2, p02B709 

    At the China Institute of Atomic Energy, a central region model cyclotron has been constructed, which is dedicated for various experimental verifications to study beam properties. The design features of the ion source and injection line have already been described in other papers. We shall...

Share