We have been studying a new heavy-ion production technique called “direct plasma injection scheme,” DPIS, since 2000. A new radio frequency quadrupole (RFQ) designed especially for the DPIS was commissioned in 2004 and very intense carbon beam was successfully obtained, reaching more than 60 mA accelerated current from the RFQ. Most of the contents of the accelerated beam was carbon 4+ as verified by beam analysis.
ACCESSION #
20618024

 

Related Articles

  • Analysis of laser-produced heavy ions for direct plasma injection scheme. Sakakibara, K.; Okamura, M.; Kondrashev, S.; Hattori, T.; Kashiwagi, H.; Kanesue, T. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03B304 

    To accelerate highly charged intense ion beam, we have developed the direct plasma injection scheme (DPIS) with laser ion source. In this scheme an ion beam from a laser ion source is injected directly to a radio frequency quadrupole (RFQ) linac without a low energy beam transport (LEBT) line...

  • Charge state breeding of radioactive ions with an electron cyclotron resonance ion source at TRIUMF. Ames, F.; Baartman, R.; Bricault, P.; Jayamanna, K.; McDonald, M.; Olivo, M.; Schmor, P.; Yuan, D. H. L.; Lamy, T. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03B103 

    Efficient primary ion sources at ISOL facilities normally produce singly charged ions. This limits the usable mass range for postacceleration due to the A/Q acceptance of the accelerator. At the ISAC facility at TRIUMF an A/Q below 7 is desired to avoid further stripping. Thus, charge state...

  • Production of energetic proton beams with lasers. Malka, V.; Faure, J.; Fritzler, S.; Manclossi, M.; Guemnie-Tafo, A.; d'Humières, E.; Lefebvre, E.; Batani, D. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03B302 

    A new method for accelerating proton beams, based on the use of intense and short laser pulses, is presented. It is shown that by focusing an ultrashort laser pulse onto a thin foil target, a proton beam with energy up to tens of MeV is produced. Due to the original properties of these beams...

  • Diagnostics for Laser Accelerators. Clayton, C. E. // AIP Conference Proceedings;2004, Vol. 737 Issue 1, p137 

    This tutorial paper discusses, at a basic level, some of the diagnostics used in plasma accelerators laboratories. Covered are measurements of laser beams, using probe laser beams to characterize the plasma itself (as opposed to the plasma wave accelerating structure) in various ways, including...

  • Evolution of rf instability in a steady-state plasma accelerator. Brukhtiı, V. I.; Kirdyashev, K. P. // Technical Physics Letters;May99, Vol. 23 Issue 5, p391 

    For the first time experimental data are obtained which indicate a stable relation between the microwave radiation intensity of a steady-state plasma accelerator and the rate of bulk erosion of the accelerating channel walls. The frequency range of the electromagnetic radiation corresponds to...

  • KVI Lamb-shift polarimeter. Beijers, J. P. M.; Kremers, H. R.; Kalantar-Nayestanaki, N. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03B505 

    The design and operation of a Lamb-shift polarimeter is discussed. This polarimeter is used to measure the polarization of proton and deuteron beams extracted from the KVI polarized-ion source. The major components of the Lamb-shift polarimeter (LSP) are described in some detail. These include...

  • Wide Dynamic Range Beam Diagnostics Measurements for Ion Accelerators. Gilpatrick, J. D. // AIP Conference Proceedings;2004, Vol. 737 Issue 1, p365 

    As light- and heavy-ion accelerator technology progresses, there will be a further demand for charged particle beam instrumentation to measure beam parameters over a very wide dynamic range. There are several different ways to express a beam diagnostic instrument’s ability to measure the...

  • Time structure of an accelerated beam using a radio-frequency quadrupole linac with direct plasma injection scheme. Kashiwagi, Hirotsugu; Okamura, Masahiro; Jameson, R. A.; Hattori, Toshiyuki; Hayashizaki, Noriyosu // Review of Scientific Instruments;Feb2010, Vol. 81 Issue 2, p02B724 

    In direct plasma injection scheme, the relation between the ion current from a laser ion source and the accelerated beam current by a radio-frequency quadrupole (RFQ) linac was studied by a series of the following analyses. First, ion current at beam extraction was calculated from measured...

  • Iron beam acceleration using direct plasma injection scheme. Okamura, M.; Kanesue, T.; Yamamoto, T.; Fuwa, Y. // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    A new set of vanes of radio frequency quadrupole (RFQ) accelerator was commissioned using highly charged iron beam. To supply high intensity heavy ion beams to the RFQ, direct plasma injection scheme (DPIS) with a confinement solenoid was adopted. One of the difficulties to utilize the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics