Effect of a compensated Jaffé creatinine method on the estimation of glomerular filtration rate

AUTHOR(S)
Chan, Michael HM; Ng, KF; Szeto, CC; Lit, Lydia CW; Chow, KM; Leung, CB; Suen, Michael WM; Li, Phillip KT; Lam, Christopher WK
PUB. DATE
November 2004
SOURCE
Annals of Clinical Biochemistry;Nov2004, Vol. 41 Issue 6, p482
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Roche Diagnostics has issued new c-fas calibrators for its automated systems. These produce creatinine values that are more comparable with those obtained by high-performance liquid chromatography. However, this results in an underestimation of measured creatinine at concentrations below 155 μmol/L and an overestimation at concentrations above this value. Methods: Serum and urine creatinine concentrations were prospectively determined on samples from 60 patients using the new (compensated) and old (uncompensated) c-fas calibrators, and Passing–Bablok regression analysis was performed. The regression equations thus determined were then used retrospectively to determine the compensated creatinine results (i.e. those results that would have been obtained using the new calibrator) in those serum and urine samples analysed in the previous year using the old uncompensated c-fas calibrator. The compensated creatinine results were then used to estimate the glomerular filtration rate (GFR) by calculating creatinine clearance. This was done by using the formula: UV/Pt, in which U represents the urinary creatinine concentration (μmol/L), V the urinary collection volume (mL), P the serum creatinine concentration (μmol/L) and t the urinary collection time (min). It was also calculated using the abbreviated Modification of Diet in Renal Disease study group (MDRD) formula. Results: The creatinine clearance as determined using either the UV/Pt calculation or the MDRD formula overestimated GFR by ~30% and ~50%, respectively, in normal individuals with a serum creatinine concentration below 155 μmol/L. However, in patients with mild to moderate renal failure (serum creatinine from 155 to 500 μmol/L), changes in creatinine clearances determined by the two procedures were minimal. Conclusion: When laboratories introduce this new, compensated calibrator into practice, it may be appropriate to discuss its potential impact with clinical staff who monitor patients using creatinine clearance.
ACCESSION #
20606498

 

Related Articles

  • Effect of a compensated Jaffé creatinine method on the estimation of glomerular filtration rate. Chan, Michael HM; Ng, KF; Szeto, CC; Lit, Lydia CW; Chow, KM; Leung, CB; Suen, Michael WM; Li, Phillip KT; Lam, Christopher WK // Annals of Clinical Biochemistry;Nov2004, Vol. 41 Issue 6, p482 

    Background: Roche Diagnostics has issued new c-fas calibrators for its automated systems. These produce creatinine values that are more comparable with those obtained by high-performance liquid chromatography. However, this results in an underestimation of measured creatinine at concentrations...

  • Answer. Magen, Daniella; Blazer, Shraga; Zelikovic, Israel // Pediatric Nephrology;Aug2002, Vol. 17 Issue 8, p697 

    Presents the answers to a clinical quiz on the association between an elevated serum creatinine level and abnormally reduced glomerular filtration rate in a newborn. Analysis of a case report; Secretion of creatinine during intrauterine life; Recommendation to pediatricians.

  • LC-MS/MS Method for Serum Creatinine: Comparison with Enzymatic Method and Jaffe Method. Ou, Meixian; Song, Yunxiao; Li, Shuijun; Liu, Gangyi; Jia, Jingying; Zhang, Menqi; Zhang, Haichen; Yu, Chen // PLoS ONE;7/24/2015, Vol. 10 Issue 7, p1 

    Accurate quantification of creatinine (Cre) is important to estimate glomerular filtration rate (GFR). Differences among various methods of Cre quantification were previously noted. This study aims to develop a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for serum Cre and...

  • Linkage of serum creatinine and glomerular filtration rate to chromosome 2 in Utah pedigrees. Hunt, Steven C.; Coon, Hilary; Hasstedt, Sandra J.; Cawthon, Richard M.; Camp, Nicola J.; Wu, Lily L.; Hopkins, Paul N. // American Journal of Hypertension;Jun2004, Vol. 17 Issue 6, p511 

    Background: Serum creatinine and creatinine clearance are used as indicators of renal function and may indicate a propensity for development of end-stage renal disease. Identifying genes related to future decreases in renal function could be important in assessing risk and defining abnormal...

  • Question. Magen, Daniella; Blazer, Shraga; Zelikovic, Israel // Pediatric Nephrology;Aug2002, Vol. 17 Issue 8, p695 

    Presents a clinical quiz on the association between an elevated serum creatinine level and abnormally reduced glomerular filtration rate in a newborn infant. Findings of the prenatal sonography; Laboratory findings; Kidney measurements.

  • Limitations of Estimating Glomerular Filtration Rate From Serum Creatinine in the General Population. Rule, Andrew D .; Rodeheffer, Richard J.; Larson, Timothy S.; Burnett, Jr., John C .; Cosio, Fernando G .; Turner, Stephen T .; Jacobsen, Steven J. // Mayo Clinic Proceedings;Nov2006, Vol. 81 Issue 11, p1427 

    OBJECTIVE: To compare estimated glomerular filtration rate (GFR) In the general population on the basis of equations derived from different subsets of the general population. PARTICIPANTS AND METHODS: Adults (ages =45 years) were randomly selected from 1997 to 2000 from the Olmsted County,...

  • Glomerular hyperfiltration and metabolic syndrome: results from the FIrenze-BAgno A Ripoli (FIBAR) Study. Monami, Matteo; Pala, Laura; Bardini, Gianluca; Francesconi, Paolo; Cresci, Barbara; Marchionni, Niccolò; Rotella, Carlo Maria; Mannucci, Edoardo // Acta Diabetologica;Sep2009, Vol. 46 Issue 3, p191 

    Metabolic syndrome (MS) has been associated with microalbuminuria and kidney disease. In the present cohort study, different methods for the estimation of glomerular filtration rate (GFR) on the basis of serum creatinine were compared with respect to their association with MS and their...

  • MDRD or CKD-EPI study equations for estimating prevalence of stage 3 CKD in epidemiological studies: which difference? Is this difference relevant? Delanaye, Pierre; Cavalier, Etienne; Mariat, Christophe; Maillard, Nicolas; Krzesinski, Jean-Marie // BMC Nephrology;2010, Vol. 11, p8 

    Background: Prevalence of stage 3 chronic kidney disease (CKD) is increasing according to the NHANES study. Prevalence has been calculated using the MDRD study equation for estimating glomerular filtration rate (GFR). Recently, a new estimator based on creatinine, the CKD-EPI equation, has been...

  • Marcadores de índice de filtración glomerular: Cistatina C. Barba Evia, José Roberto // Revista Mexicana de Patologia Clinica;jul-sep2008, Vol. 55 Issue 3, p149 

    Serum creatinine concentration is the most commonly used diagnostic marker for the clinical assessment of glomerular filtration rate (GFR); however, has a range of nonrenal factors influencing their production, for example: muscle mass and protein intake, and for creatinine there are several...

  • Adult reference ranges for serum cystatin C, creatinine and predicted creatinine clearance. Finney, Hazel; Newman, David J.; Price, Christopher P. // Annals of Clinical Biochemistry;Jan2000, Vol. 37 Issue 1, p49 

    Serum cystatin C measurement has been previously shown by ourselves and others to be a better indicator of changes in glomerular filtration rate (GFR) than serum creatinine. However, the available literature on reference values for cystatin C concentration remains surprisingly sparse; we thus...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics