TITLE

Heat Effects on the Retina

AUTHOR(S)
Piyathaisere, Duke V.; Margalit, Eyal; Shih-Jen Chen; Jeng-Shyong Shyu; D'Anna, Salvatore A.; Weiland, James D.; Grebe, Rhonda R.; Grebe, Lynnea; Fujii, Gildo; Sahng Yeon Kim; Greenberg, Robert J.; De Juan Jr., Eugene; Humayun, Mark S.
PUB. DATE
March 2003
SOURCE
Ophthalmic Surgery, Lasers & Imaging;Mar/Apr2003, Vol. 34 Issue 2, p114
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
BACKGROUND AND OBJECTIVE: To study the heat and power dissipation effect of an intraocular electronic heater on the retina. The determination of thermal parameters that are nonharmful to the retina will aid in the development of an implantable intraocular electronic retinal prosthesis. MATERIALS AND METHODS: In dogs, five different retinal areas were touched with a custom intraocular heater probe (1.4 x 1.4 x 1.0 mm) for 1 second while the heater dissipated 0 (control), 10, 20, 50, or 100 mW. In a second protocol, the heater was mechanically held in the vitreous cavity while dissipating 500 mW for 2 hours while monitoring intraocular temperature. The animals were observed for 4 weeks with serial fundus photography and electroretinography. The procedure was then repeated in the fellow eye. The dogs were killed and both eyes were enucleated and submitted for histology. RESULTS: In experiments using protocol 1, heater settings of 50 mW or higher caused an immediate visible whitening of the retinal tissue. Histologically, this damage was evident only if the eyes were immediately enucleated. Permanent damage was caused by heater settings of 100 mW or higher. Under protocol 2, no ophthalmologic, electroretinography, or histologic differences were noted between the groups. Temperature increases of 5°C in the vitreous and 2°C near the retina were noted. CONCLUSIONS: The liquid environment of the eye acts as a heat sink that is capable of dissipating a significant amount of power. An electronic chip positioned away from the retina can run at considerably higher powers than a chip positioned on the retinal surface.
ACCESSION #
20066697

 

Related Articles

  • Clinical outcomes and functional visual performance: comparison of the ReSTOR apodised diffractive intraocular lens to a monofocal control. R J Cionni // British Journal of Ophthalmology;Sep2009, Vol. 93 Issue 9, p1215 

    AIMS: To compare clinical outcomes of patients bilaterally implanted with SN60D3 intraocular lenses (IOLs) with outcomes of bilateral monofocal controls, and to determine the validity of implanting an apodised diffractive lens in a healthy patient population. METHODS: Six unmasked US...

  • Patients with phakic IOLs should be seen twice a year. Groves, Nancy // Ophthalmology Times;11/1/2007, Vol. 32 Issue 21, p48 

    The article presents information on the findings of a research study on patients with phakic intraocular lenses (IOLs). The study was conducted by physician Matteo Piovella and colleagues. According to Piovella, patients in whom phakic IOLs have been implanted should undergo complex eye...

  • High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis. Talukder, Mohammad Ismail; Siy, Pepe; Auner, Gregory W. // Open Ophthalmology Journal;2008, Vol. 2, p77 

    By a retinal prosthesis, the researchers have been able to stimulate a limited number of neurons (around 100) by biphasic current stimulus to reproduce an image spatially by multiplexing technique. For functional restoration of sight (visual acuity 20/80), we are to stimulate at least 2500...

  • POINT/COUNTER. Probst, Louis E.; Aker, Alan B. // Ocular Surgery News;10/25/2009, Vol. 27 Issue 20, p11 

    The article presents a debate on which between laser-based refractive surgery and premium intraocular lens (IOL) implantation is a better value for patients. One author argues that refractive surgery is safer, more accurate, more convenient and more cost effective than IOL. While another author...

  • 'Iris finger printing' orients toric lOLs. Guttman, Cheryl; Raghunath, Anitha; Schiffman, Jade // Ophthalmology Times;5/15/2009, Vol. 34 Issue 10, p1 

    The article focuses on the use of iris fingerprinting in orienting toric intraocular lenses (IOLs) for performing astigmatic cataract surgery as recommended by Robert H. Osher, ophthalmology professor at the University of Cincinnati College of Medicine. It explains the procedure of iris...

  • In-the-bag IOL subluxation managed with glue-assisted implantation technique. Agarwal, Amar; Kumar, Dhivya Ashok // Ocular Surgery News Europe;Sep2009, Vol. 20 Issue 8, p38 

    This article discusses the case of a 58-year-old man who presented with a bilateral anterior intraocular lens (IOL) subluxation. Particular focus is given to his medical history, as well as his best correct visual acuity upon ocular examination. Anterior capsular fibrosis and contracture were...

  • Temporal approach helps in AC lens. Koch, Paul S.; Greenberg, Kenneth A.; Sabbagh, Leslie B. // Ophthalmology Times;01/01/99, Vol. 24 Issue 1, p1 

    Reports on the phase II trials for the Ophtec Artisan anterior chamber phakic intraocular lens. Use of temporal approach to the implantation; Results achieved with the lenses; Potential for complications.

  • Toric IOLs improve vision in cataract patients with previous PK. Hasson, Matt // Ocular Surgery News Europe/Asia-Pacific Edition;Apr2009, Vol. 20 Issue 4, p17 

    The article focuses on a study which examined the clinical efficacy of toric intraocular lens (IOL) in patients who had previous corneal transplants.

  • Phakic IOL offers adjustability, removability, safety. Guell, Jose L.; Waring III, George O. // Ophthalmology Times;07/15/2000, Vol. 25 Issue 14, p7 

    Presents information on the improvements in intraocular lenses implanted in phakic eye. Types and categories; Implantation technique; Recommendations about its use.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics