TITLE

Serial separation of cations and anions by ion chromatography using the peak parking technique and sulfosalicylic acid as the eluent

AUTHOR(S)
Amin, Muhammad; Lee Wah Lim; Takeuchi, Toyohide
PUB. DATE
January 2006
SOURCE
Analytical & Bioanalytical Chemistry;Jan2006, Vol. 384 Issue 3, p839
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An improvement of the peak parking technique is described for the serial determination of cations (Na+, % MathType!Translator!2!1!AMS LaTeX.tdl!TeX -- AMS-LaTeX!% MathType!MTEF!2!1!+-% feaaeaart1ev0aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX% garmWu51MyVXgatuuDJXwAK1uy0HwmaeHbfv3ySLgzG0uy0Hgip5wz% aebbnrfifHhDYfgasaacH8qrps0lbbf9q8WrFfeuY-Hhbbf9v8qqaq% Fr0xc9pk0xbba9q8WqFfea0-yr0RYxir-Jbba9q8aq0-yq-He9q8qq% Q8frFve9Fve9Ff0dmeaabaqaciGacaGaaeqabaWaaeWaeaaakeaaru% avP1wzZbItLDhis9wBH5gaiuaacaWFobGaa8hsamaaDaaaleaacaWF% 0aaabaGaa83kaaaaaaa!4042! $$NH^{ + }_{4} $$ , K+, Mg2+, and Ca2+) and anions (Cl−, % MathType!Translator!2!1!AMS LaTeX.tdl!TeX -- AMS-LaTeX!% MathType!MTEF!2!1!+-% feaaeaart1ev0aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX% garmWu51MyVXgatuuDJXwAK1uy0HwmaeHbfv3ySLgzG0uy0Hgip5wz% aebbnrfifHhDYfgasaacH8qrps0lbbf9q8WrFfeuY-Hhbbf9v8qqaq% Fr0xc9pk0xbba9q8WqFfea0-yr0RYxir-Jbba9q8aq0-yq-He9q8qq% Q8frFve9Fve9Ff0dmeaabaqaciGacaGaaeqabaWaaeWaeaaakeaaru% avP1wzZbItLDhis9wBH5gaiuaacaWFtbGaa83tamaaDaaaleaacaWF% 0aaabaGaa8Nmaiaa-1caaaaaaa!4103! $$SO^{{2 - }}_{4} $$ , and % MathType!Translator!2!1!AMS LaTeX.tdl!TeX -- AMS-LaTeX!% MathType!MTEF!2!1!+-% feaaeaart1ev0aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbbjxAHX% garmWu51MyVXgatuuDJXwAK1uy0HwmaeHbfv3ySLgzG0uy0Hgip5wz% aebbnrfifHhDYfgasaacH8qrps0lbbf9q8WrFfeuY-Hhbbf9v8qqaq% Fr0xc9pk0xbba9q8WqFfea0-yr0RYxir-Jbba9q8aq0-yq-He9q8qq% Q8frFve9Fve9Ff0dmeaabaqaciGacaGaaeqabaWaaeWaeaaakeaaru% avP1wzZbItLDhis9wBH5gaiuaacaWFobGaa83tamaaDaaaleaacaWF% ZaaabaGaa8xlaaaaaaa!404A! $$NO^{ - }_{3} $$ ) using a single pump, a single eluent and a single detector. The present system used commercially-available unmodified cation exchange and anion exchange columns, which were attached to each switching valve. When 1.75 mM 5-sulfosalicylic acid was used as the eluent, serial separation of the above cations and anions was achieved in less than 20 min. The proposed ion chromatographic method was successfully applied to the serial determination of cations and anions in tap water and river water samples. The limits of detection at S/N=3 for an injection of 20 μl were 16–68 ppb (μg/l) for cations and 15–28 ppb for anions.
ACCESSION #
19718186

 

Related Articles

  • Peak parking technique for the simultaneous determination of anions and cations. Amin, Muhammad; Lee Wah Lim; Takeuchi, Toyohide // Analytical & Bioanalytical Chemistry;Apr2005, Vol. 381 Issue 7, p1426 

    An ion chromatography method is described for the simultaneous determination of anions (Cl-, NO, and SO) and cations (Na+, NH, K+, Mg2+, and Ca2+) using a single pump, a single eluent and a single detector. An anion-exchange column modified with chondroitin sulfate C facilitated the elution of...

  • Quantification of free and total salicylic acid in plants by solid-phase extraction and isocratic high-performance anion-exchange chromatography. Rozhon, Wilfried; Petutschnig, Elena; Wrzaczek, Michael; Jonak, Claudia // Analytical & Bioanalytical Chemistry;Aug2005, Vol. 382 Issue 7, p1620 

    Salicylic acid (SA) is an important signaling compound in plants and is involved in various defense responses. Here we report a new method for quantification of free and total soluble SA in Arabidopsis thaliana with 5-fluorosalicylic acid (5-FSA) as internal standard. The SA was isolated from...

  • Modern stationary phases for ion chromatography. Weiss, J.; Jensen, D. // Analytical & Bioanalytical Chemistry;Jan2003, Vol. 375 Issue 1, p81 

    Due to the better understanding of the processes taking place at the surface of the stationary phases, the number of ion-exchange materials for ion chromatography (IC) has increased tremendously over recent years. As a result, the multitude of commercially available columns today with their...

  • Biofuel Analysis by Ion Chromatography. Steinbach, Alfred; Wille, Andrea; Subramanian, N. Harihara // LC-GC Europe;Mar2008 Applications Book, p35 

    The article focuses on a study providing an overview of ion chromatographic methods used for simple and accurate determination of alkali metals, alkaline earth metals, antioxidants, chloride and sulphates in biofuel. It states that while antioxidants are detected by ultraviolet detection, the...

  • Poly(ethylene oxide)-bonded stationary phase for capillary ion chromatography. Takeuchi, Toyohide; Oktavia, Budhi; Lee Wah Lim // Analytical & Bioanalytical Chemistry;Feb2009, Vol. 393 Issue 4, p1267 

    Methyl-capped poly(ethylene oxide) moieties were chemically bonded to silica gel using an amine-reactive modification reagent and evaluated as the stationary phase for ion chromatography. In this work, primary amino groups of an aminopropylsilica packing material were reacted with...

  • Simultaneous Determination of Positive and Negative Counterions Using a Hydrophilic Interaction Chromatography Method. Risley, Donald S.; Pack, Brian W. // LC-GC North America;Aug2006, Vol. 24 Issue 8, p766 

    The objective of this work was to develop a universal high performance liquid chromatography method that is capable of simultaneously retaining and separating both cations and anions within a single chromatographic analysis for the purpose of quantification in pharmaceutical products. A...

  • Simultaneous Separation of Pharmaceutical Counterions on a Reversed-Phase/Anion-Exchange/Cation-Exchange Tri-Mode HPLC Column. Xiaodong Liu; Pohl, Christopher // LC-GC North America;Jun2009 Application Notebook, Vol. 27, p50 

    The article discusses the separation of pharmaceutical counterions on several properties including a reversed-phase, anion-exchange, and cation-exchange with the Acclaim Trinity P1. It notes the column selectivity which is designed such that cations elute before anions, or elute in separate time...

  • Amino Acid Analyzers. Sherma, Joseph; D., John; Larkin, Frances H. // Journal of AOAC International;Nov/Dec2003, Vol. 86 Issue 6, p141A 

    Describes the use of amino acid analysis of clinical plasma or urine samples in providing essential information for determining patient's metabolic and nutritional condition. Cause of differential ellution of the amino acids from a strong acid cation exchange column; Combination of anion...

  • Application of Ion Chromatography for the Determination of Inorganic Ions, Especially Thiocyanates, in Human Semen Samples as Biomarkers of Environmental Tobacco Smoke Exposure. Demkowska, Ilona; Polkowska, Żaneta; Kiełbratowska, Bogumiła; Namieśnik, Jacek // Journal of Analytical Toxicology;Nov/Dec2010, Vol. 34 Issue 9, p533 

    The article presents a study which seeks to determine the presence of thiocyanates and certain ions through ion chromatography in semen samples from male smokers and nonsmokers alike. It states that the study was performed through examination of semen by ion chromatograph Dionex DX500 followed...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library