TITLE

Direct Access Valve Replacement (DAVR) – are we entering a new era in cardiac surgery?

AUTHOR(S)
Huber, Christoph H.; von Segesser, Ludwig K.
PUB. DATE
March 2006
SOURCE
European Journal of Cardio-Thoracic Surgery;Mar2006, Vol. 29 Issue 3, p380
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Abstract: Objective: This study validates the off-pump antegrade trans-ventricular route for ultrasound-guided direct access aortic valve replacement. Direct access aortic valve replacement using a transthoracic and valved stent-based approach offers numerous advantages over the remote access percutaneous approach and may one day provide an alternative treatment modality for aortic valve disease. Methods: Valved stents were implanted off-pump in 17 pigs (72.10±8.4kg) via the direct access transapical approach using a left-sided mini-thoracotomy and continuous ultrasonic and fluoroscopic guidance. Acute valved stent function was studied with intravascular and two-dimensional intracardiac ultrasound. The invasive valve gradient was assessed with pull-back pressure catheter. All valved stents were tested in vitro before insertion. Macroscopic analysis was performed at necropsy. Results: In 11 of the 17 pigs, valved stents were delivered to the target site over the native aortic valve leaflets without interference of coronary blood flow and with good acute valve function. Three valved stents were deployed supra-annularly, two of those occluded the right coronary orifice and one the left coronary orifice, leading to fatal outcomes. Three valved stents dislodged into the left ventricle, one because of size-mismatch and two because of failure to unfold correctly. In 11 properly sized and deployed valved stents, two showed a moderate and one a severe paravalvular leak. Conclusions: Seventeen pigs underwent direct access valve replacement of the aortic valve with deployment of a valved stent into the native aorta. Eleven valves observed for an average 5-h period showed satisfactory, postimplantation valve function.
ACCESSION #
19687948

 

Related Articles

  • Quantification of Biomechanical Interaction of Transcatheter Aortic Valve Stent Deployed in Porcine and Ovine Hearts. Mummert, Joseph; Sirois, Eric; Sun, Wei // Annals of Biomedical Engineering;Mar2013, Vol. 41 Issue 3, p577 

    Success of the deployment and function in transcatheter aortic valve replacement is heavily reliant on the tissue-stent interaction. The present study quantified important tissue-stent contact variables of self-expanding transcatheter aortic valve stents when deployed into ovine and porcine...

  • Aortic dissection causing embolic stroke. Fernandez, E.; Nadig, Raghunandhan; Mathew, Thomas; Sarma, G. R. K. // Neurology India;Sep2009, Vol. 57 Issue 5, p689 

    The article presents the case of a 45-year-old female having hypertensive for the past five years and an episode of generalized seizure. Her magnetic resonance imaging (MRI) revealed a multiple small hyperintense lesions involving bilateral subcortial areas and cerebellar white matter. It...

  • The Ross procedure offers excellent survival compared with mechanical aortic valve replacement in a real-world setting†. Andreas, Martin; Wiedemann, Dominik; Seebacher, Gernot; Rath, Claus; Aref, Tandis; Rosenhek, Raphael; Heinze, Georg; Eigenbauer, Ernst; Simon, Paul; Ruetzler, Kurt; Hiesmayr, Joerg-Michael; Moritz, Anton; Laufer, Guenther; Kocher, Alfred // European Journal of Cardio-Thoracic Surgery;Sep2014, Vol. 46 Issue 3, p409 

    OBJECTIVES The ideal prosthesis for young patients requiring aortic valve replacement has not been defined to date. Although the Ross procedure provides excellent survival, its application is still limited. We compared the long-term survival after the Ross procedure with mechanical aortic valve...

  • In vitro results of a new minimally invasive aortic valve resecting tool Wendt, Daniel; Müller, Wiebke; Hauck, Florian; Thielmann, Matthias; Wendt, Hermann; Kipfmüller, Brigitte; Vogel, Bernd; Jakob, Heinz // European Journal of Cardio-Thoracic Surgery;Apr2009, Vol. 35 Issue 4, p622 

    Abstract: Background: Aortic valve replacement (AVR) using extracorporeal circulation is currently the treatment of choice for symptomatic aortic stenosis. However, patients with multiple high-risk comorbid conditions may benefit from reduced ECC time by a simplified and faster resection in...

  • Population screening for TAVI procedure. Redzek, A.; Velicki, L.; Petrovic, M.; Mihajlovic, B.; Fabri, M.; Nicin, S. // Journal of Cardiothoracic Surgery;2013, Vol. 8 Issue Suppl 1, p1 

    An abstract of the article "Population screening for TAVI procedure" by A. Redzek and colleagues is presented.

  • Conventional surgery results in patients originally referred for transcatheter aortic valve implantation. Rescigno, G.; Piva, T.; Mazzanti, I.; Aratari, C.; Pupita, G.; D'Alfonso, A.; Capucci, A.; Perna, G. P.; Torracca, L. // Journal of Cardiothoracic Surgery;2013, Vol. 8 Issue Suppl 1, p1 

    An abstract of the article "Conventional surgery results in patients originally referred for transcatheter aortic valve implantation" by G. Rescigno and colleagues is presented.

  • Considerations on the poor discriminatory power of the FRANCE-2 risk score: Authors' reply. Iung, Bernard; Laouenan, Cedric; Vahanian, Alec; Gilard, Martine // Heart;Jul2015, Vol. 101 Issue 14, p1170 

    A response from the author of the article "Considerations on the poor discriminatory power of the FRANCE-2 risk score" in 2015 issue is presented.

  • Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging. KneŞaurek, Karin; Machac, Josef; Zhuangyu Zhang // BMC Medical Physics;2009, Vol. 9, p1 

    Background: We evaluated the repeatability of the calculation of myocardial blood flow (MBF) at rest and pharmacological stress, and calculated the coronary flow reserve (CFR) utilizing 82Rb PET imaging. The aim of the research was to prove high repeatability for global MBF and CFR values and...

  • Aortic valve replacement using a stentless bioprosthesis through right minithoracotomy: An initial experience Sansone, Fabrizio; Zingarelli, Edoardo; Punta, Giuseppe; Flocco, Roberto; Dato, Guglielmo Mario Actis; Forsennati, Pier Giuseppe; Parisi, Francesco; Bardi, Gian Luca; del Ponte, Stefano; Casabona, Riccardo // Heart, Lung & Circulation;Aug2011, Vol. 20 Issue 8, p543 

    Objective: Aortic valve replacement (AVR) is nowadays a safe procedure with low rates of mortality and morbidity, but the necessity for a less invasive approach is going to increase. The use of a stentless prosthesis through right mini-thoracotomy has not yet been described and our experience...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics