Albumin in the cardiopulmonary bypass prime: how little is enough?

AUTHOR(S)
Palanzo, D.A.; Zarro, D.L.; Montesano, R.M.; Manley, N.J.
PUB. DATE
May 1999
SOURCE
Perfusion;1999, Vol. 14 Issue 3, p167
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Previous studies have demonstrated high transoxygenator pressures with noncoated hollow-fiber membrane oxygenators. These reports have been associated with dramatic platelet count drops during cardiopulmonary bypass (CPB). It has also been shown that adding human albumin to the prime of the bypass circuit reduces, if not eliminates, these problems. This study was conducted to determine what is the smallest amount of albumin added to the prime that will still display its protective effects. Eighty patients undergoing nonemergency open-heart surgery were randomly divided into four groups. Groups I and II received the Sarns Turbo 440 oxygenator with 0.0375 g of albumin/100 ml of prime and 0.125 g of albumin/100 ml of prime, respectively, added to the pump prime. Groups III and IV received the Medtronic Maxima-PRF oxygenator with 0.0375 g of albumin/100 ml of prime and 0.125 g of albumin/100 ml of prime, respectively, added to the pump prime. Pre-CPB, on CPB (15--20 min after the initiation of bypass) and warming hemoglobin, hematocrit and platelet counts were drawn on all patients. Net platelet count drop, which accounted for hemodilutional effects, was calculated for all specimens and compared to previous results obtained from the test oxygenators without albumin in the prime. The net platelet count drops for the study groups were as follows: Sarns oxygenator with no albumin in the prime = 11.8 ± 12.5%; Sarns oxygenator with 0.0375 g of albumin/100 ml prime = -3.7 ± 10.8%; Sarns oxygenator with 0.125 g of albumin/100 ml prime = -2.0 ± 12.6%; Medtronic oxygenator with no albumin in the prime = 20.1 ± 14.5%; Medtronic oxygenator with 0.0375 g albumin/100 ml prime = -6.9 ± 8.7%; and Medtronic oxygenator with 0.125 g albumin/100 ml prime = -14.0 ± 12.4%. Our results illustrate that adding as little as 0.0375 g albumin/100 ml prime 3 ml of 25% solution/2000 ml of prime) to the pump prime illicits the beneficial effects of surface coating on platelet loss during CPB.
ACCESSION #
1950044

 

Related Articles

  • Effect of temperature on blood parameters of the salamander Batrachupems tibetanus (Schmidt, 1925) (Amphibia: Hynobiidae). Xiaochen Li // Russian Journal of Ecology;Jan2010, Vol. 41 Issue 1, p102 

    Abstract  To better understand how Batrachupems tibetanus responds to different temperature regimes in the blood parameters and to estimate the change in plasma cortisol level in this species exposed to different temperatures, the animals were stochastically divided into three...

  • Cellular Specificity of the Blood–CSF Barrier for Albumin Transfer across the Choroid Plexus Epithelium. Liddelow, Shane A.; Dzięgielewska, Katarzyna M.; Møllgård, Kjeld; Whish, Sophie C.; Noor, Natassya M.; Wheaton, Benjamin J.; Gehwolf, Renate; Wagner, Andrea; Traweger, Andreas; Bauer, Hannelore; Bauer, Hans-Christian; Saunders, Norman R. // PLoS ONE;Sep2014, Vol. 9 Issue 9, p1 

    To maintain the precise internal milieu of the mammalian central nervous system, well-controlled transfer of molecules from periphery into brain is required. Recently the soluble and cell-surface albumin-binding glycoprotein SPARC (secreted protein acidic and rich in cysteine) has been...

  • Efficiency of Levosimendan therapy in heart failure: Is it efficient on patients with cardiac dyssynchrony? Buyuklu, Mutlu; Set, Turan; Tatlı, Ersan; Barutcu, Ahmet; Aksu, Feyza // HealthMed;2012, Vol. 6 Issue 4, p1356 

    Aim: Levosimendan is a new inotropic drug used in acute heart failure for its cardiac contractility increasing effect without increasing myocar-dial oxygen consumption. Longer QRS duration is an important prognostic indicator independent of the underlying heart disease. In heart failure,...

  • Ischemia-modified albumin levels in professional male soccer players before and after training. Duman, Can; Çolak, Tuncay; Bamaç, Belgin; Göker, İmran; Çolak, Serap; Özbek, Aydın // Marmara Medical Journal;2013, Vol. 26 Issue 1, p21 

    Objectives: The ischemia-modified albumin (IMA) test is a promising indicator of myocardial ischemia in the early diagnosis of the acute coronary syndrome (ACS). Recent studies examining alterations in IMA levels caused by myocardial ischemia that develops during exercise have shown...

  • Serum Albumin and Prealbumin Predict the Poor Outcome of Traumatic Brain Injury. Chen, Du; Bao, Long; Lu, Shi-qi; Xu, Feng // PLoS ONE;Mar2014, Vol. 9 Issue 3, p1 

    Background: Serum albumin and prealbumin are both negative acute-phase reactants, and usually at low levels in stress. We aim to determine their predictive values for poor outcome of traumatic brain injury (TBI). Methods: A total of 326 patients of TBI were enrolled and followed-up by telephone...

  • The effect of energy increasing and protein lowering on performance and some serum biochemical parameters of broiler chickens. Riyazi, Seyyed Reza; Vahdatpour, Tohid; Mirzaei-Aghsaghali, Afshar; Fathi, Hasan; Davoodi, Jaber; Vahdatpour, Sina // Annals of Biological Research;2011, Vol. 2 Issue 4, p516 

    This experiment was conducted to determine the effects of increasing energy to protein ratio and partial decreasing of nutrient contents of diet using different levels of fats on broiler chickens performance and serum biochemical parameters. With addition of fats (poultry oil, soybean oil and...

  • Bioquímica plasmática de cascavéis (Caudisona durissa LINNAEUS, 1758) em cativeiro. da Silva, Wellington Bandeira; Soares, Rodrigo Machado; Machado, Claudio; Freire, Isabel Maria Alexandre; da Silva, Luiz César Cavalcanti Pereira; Moreira, Silvia Bahadian; Goldberg, Daphne Wrobel; Almosny, Nádia Regina Pereira // Ciência Rural;dez2010, Vol. 40 Issue 12, p2510 

    Human accidents involving rattlesnake Caudisona durissa have the highest fatality rate among the Brazilian Viperidae family. Breeding this specie in captivity in order to produce antivenoms is very important to public health. Nevertheless, there are some challenges that this activity must face,...

  • Hematological Findings Among Workers Exposed to Benzene at a Coke Oven By-Product Recovery Facility. Hancock, D. Gary; Moffitt Jr, Augustine E.; Hay, Erroll B. // Archives of Environmental Health;Nov/Dec84, Vol. 39 Issue 6 

    Examines hematological findings among workers exposed to benzene at a Coke Oven By-Product Recovery Facility. Determination of red blood counts, white blood counts and hemoglobin levels; Influence of other chemicals present; Existence of possible threshold for nonleukemogenic, hematoxic effects.

  • Excess mortality after human albumin administration in critically ill patients. Offringa, Martin // BMJ: British Medical Journal (International Edition);07/25/98, Vol. 317 Issue 7153, p223 

    Editorial. Presents an overview of the clinical and pathophysiological evidence on the effects of the colloid, albumin on humans. Details on the chance that cardiac decompensation may occur after rapid volume replacement with 20 percent albumin; What albumin is used for; What clinical and...

Share

Read the Article

Courtesy of

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics