TITLE

Findings of Personalized Ventilation Studies in a Hot and Humid Climate

AUTHOR(S)
Sekhar, S. C.; Gong, N.; Tham, K. W.; Cheong, K. W.; Melikov, A. K.; Wyon, D. P.; Fanger, P. O.
PUB. DATE
October 2005
SOURCE
HVAC&R Research;Oct2005, Vol. 11 Issue 4, p603
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The concept of personalized ventilation (PV) is at the cutting edge of technological development in the area of air conditioning and is fundamentally aimed at improving ventilation in Ihe immediate breathing zones of occupants in the built environment. While the current state-of-the-art PV systems, make this possible for seated individuals within the occupied zone, it is envisaged that flexible PV systems, extending the range of applicalion within the dynamic movements of individuals in an air-conditioned zone, may be a reality in the near future. The abilily of PV systems to enhance thermal comfort and indoor air quality (IAQ) and the energy savings that would result were examined under the hot and humid tropical conditions of Singapore. The experimental design consisted of 17 different environmental conditions, characterized by a combination of room ambient temperature (23�C and 26�), PV air temperature (20�C, 23�C, and 26�C), and the PV airflow rate (7, 11, and 15 l/s per person). The experimenlal design also included a reference condition wilt the primary background air-conditioning system operating under the same conditions but without PV air. Eleven human subjects took part in all the experiments and a detailed questionnaire was employed to solicit their subjective responses during each exposure. Air velocily, air temperature, and ventilation effectiveness were measured in the immediate breathing zone of each occupant. The results indicate that the use of a secondary PV system in conjunction with a primary air-conditioning system not only enhances thermal comfort and IAQ acceptability but can reduce energy consumption by 15-30%. PV systems can improve ventilation effectiveness at the immediate breathing zone by up to 50% more than can be obtained with mixing ventilation (MV) alone, and PV tends to lower the average temperalure of inhaled air in the breathing zone by 2-5 �C, enhancing perceived air quality. PV temperature and PV flow rate were found to be more critical than ambient temperature for occupants' thermal comfort and the perceived air quality of inhaled air.
ACCESSION #
19299549

 

Related Articles

  • Evaluation of Demand-Controlled Ventilation and Enthalpy Exchangers in Small Commercial Buildings. Mercer, Kevin B.; Braun, James E. // ASHRAE Transactions;2005, Vol. 111 Issue 1, p873 

    The ventilation airstream required to maintain acceptable indoor air quality is typically a .significant contributor to the total heating and cooling load in commercial buildings. Demand-controlled ventilation (DCV) and enthalpy exchangers are two technologies that can be used to reduce...

  • Ventilation Control Strategy Using the Supply CO2 Concentration Setpoint. Nassif, Nabil; Kajl, Stanislaw; Sabourin, Robert // HVAC&R Research;Apr2005, Vol. 11 Issue 2, p239 

    This paper proposes a new ventilation control strategy applied to multiple spaces subject to variable occupancy. The strategy specified for real-time, online ventilation control takes advantage of uninitiated air from some overventilated spaces to be used as fresh outdoor air in order to reduce...

  • Ventilation in the balance. Fabricius, Lars // Heating & Ventilating Review;May2012, Vol. 51 Issue 7, p26 

    The article argues that decentralised air handling units (AHUs) in a commercial environment in Great Britain provide an alternative to traditional ductwork systems with the need to balance indoor air quality (IAQ) with energy consumption. Issues addressed include noise reduction, minimised air...

  • Analysis of the Impact of CO2 -Based Demand-Controlled Ventilation Strategies on Energy Consumption. Krarti, Moncef; Al-Alaw, Mohsin // ASHRAE Transactions;2004, Vol. 110 Issue 1, p274 

    This paper presents an integrated IAQ/HVAC simulation environment that can model the impact of contaminant-based demand-controlled ventilation (DCV) strategies on both indoor air quality and HVAC system energy use for multizone buildings. The predictions of the integrated IAQ/HVAC simulation...

  • Modeling the Performance of Personalized Ventilation under Different Conditions of Room Air and Personalized Air. Gao, Naiping; Niu, Jianlei // HVAC&R Research;Oct2005, Vol. 11 Issue 4, p587 

    Building-related health complaints and sick building syndrome (SBS) represent significant health problems. Personalized ventilation (PV) is able to provide better inhaled air quality since the fresh air is supplied directly to the breathing zone "gently." In this paper, after the numerical...

  • CLIMA 2005 Congress Presents New Advances in Technology.  // ASHRAE Journal;Dec2005, Vol. 47 Issue 12, p10 

    The article presents information on CLIMA 2005, the World HVAC&R Congress, organized by REHVA, the European air-conditioning federation, held in Lausanne, Switzerland. The focus of the congress was on emerging technologies and improved means of measuring performance of systems. Gordon V.R....

  • Specifying air curtains for savings and performance. Johnson, David // Consulting-Specifying Engineer;Apr2009, Vol. 45 Issue 4, Special section p18 

    The article focuses on the air curtains which provide a controlled stream of air across a building entrance or doorway to separate interior and exterior environments. They can provide low-first cost and low total cost of ownership for entrances, loading doors and other applications. In addition,...

  • Effectiveness of Photocatalytic Filter for Removing Volatile Organic Compounds in the Heating, Ventilation, and Air Conditioning System. Kuo-Pin Yu; Lee, Grace Whei-May; Wei-Ming Huang; Chih-Cheng Wu; Chia-ling Lou; Shinhao Yang // Journal of the Air & Waste Management Association (Air & Waste M;May2006, Vol. 56 Issue 5, p666 

    Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as...

  • Development of Energy-Efficient Single-Coil Twin-Fan Air-Conditioning System with Zonal Ventilation Control. Sekhar, S. C.; Tham, K. W.; Maheswaran, Uma; Cheong, K. W. // ASHRAE Transactions;2004, Vol. 110 Issue 2, p204 

    Indoor air quality (IAQ) is strongly affected by the various sources of indoor pollutants and the efficiency of the ventilation system. Higher ventilation demands pose an enormous energy penalty, particularly in the tropics, and this paper presents a new method of air conditioning that addresses...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.