TITLE

Time-of-flight system with a movable ion detector for absolute measurement of cyclotron beam energy

AUTHOR(S)
Okumura, S.; Kurashima, S.; Miyawaki, N.; Yoshida, K.; Fukuda, M.
PUB. DATE
November 2005
SOURCE
Review of Scientific Instruments;Nov2005, Vol. 76 Issue 11, p113106
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A time-of-flight system for determining the absolute energy of ion beams has been developed for the azimuthally varying field (AVF) cyclotron at Japan Atomic Energy Agency (JAEA). Ion detectors, a microchannel-plate detector and a plastic scintillation detector, were applied to the system in order to achieve high time resolution measurement of the flight time and to cover a wide range of beam intensity in combination with a beam attenuator. The change of the flight length, performed by moving the plastic scintillation detector with flexible bellows, allows determination of the mean beam energy only from the relative measurement of the flight time and the flight length without knowing their absolute values. A maximum movable distance of 2 m yields the difference in the time of flight from 16 to 94 ns for the energy range of ion beams accelerated by the JAEA AVF cyclotron. The time-of-flight system even with the 2 m change in the flight length achieves accurate energy determination of the order of 0.1%, since the relative measurement has an advantage of elimination of the uncertainties in determination of the time zero and the length zero. The time-of-flight measurement with the relative measurement also allows estimation of the beam energy spread without conventional expensive systems such as a magnetic spectrometer. By comparing the widths of the time-of-flight spectra of ions accumulated at different flight lengths, we have estimated the energy spread. In order to reduce the labor process of the coincidence detection of ions in the time-of-flight measurement, we have also accomplished a simple estimation method for mean beam energy determination with a beam bunch, naturally modulated with the acceleration RF of the cyclotron. The mean beam energy has been obtained from the shift of the beam bunch centroids at different flight lengths in the time-of-flight spectrum.
ACCESSION #
19215139

 

Related Articles

  • Simple and inexpensive time-of-flight charge-to-mass analyzer for ion beam source characterization. Gushenets, V. I.; Nikolaev, A. G.; Oks, E. M.; Vintizenko, L. G.; Yushkov, G. Yu.; Oztarhan, A.; Brown, I. G. // Review of Scientific Instruments;Jun2006, Vol. 77 Issue 6, p063301 

    We describe the design, electronics, and test results of a simple and low-cost time-of-flight ion charge-to-mass analyzer that is suitable for ion source characterization. The method selects a short-time sample of the beam whose charge-to-mass composition is then separated according to ion...

  • Reconstructing the particle direction in an extended aperture of the PAMELA apparatus using the coordinate-sensitive calorimeter. Borisov, S.; Voronov, S.; Galper, A.; Karelin, A. // Instruments & Experimental Techniques;Jan2013, Vol. 56 Issue 1, p1 

    A method for reconstructing the track and the direction of a particle hitting the detector using a coordinate-sensitive calorimeter has been developed in the context of the PAMELA experiment. To extend the standard detector aperture determined by the geometrical dimensions of the magnetic...

  • Measurements of cosmic-ray antiprotons with PAMELA. Wu, J. // Astrophysics & Space Sciences Transactions (ASTRA);2011, Vol. 7 Issue 2, p225 

    The PAMELA experiment is a satellite-borne apparatus designed to study charged particles, and especially antiparticles, in the cosmic radiation. The apparatus is mounted on the Resurs DK1 satellite which was launched on 15 June 2006. PAMELA has been traveling around the earth along an elliptical...

  • A new Time-of-Flight mass measurement project for exotic nuclei and ultra-high precision detector development. Bao-Hua Sun; Jian-Wei Zhao; Wen-Qi Yan; Le, X. Y.; Wen-Jian Lin; Song, C. Y.; Tanihata, Isao; Terashima, S.; Wang, T. F.; Zhang, S. S.; Zhu, L. H. // EPJ Web of Conferences;2016, Vol. 109, p1 

    The time-of-flight (TOF) mass spectrometry (MS), a high-resolution magnetic spectrometer equipped with a fast particle tracking system, is well recognized by its ability in weighing the most exotic nuclei. Currently such TOF-MS can achieve a mass resolution power of about 2X 10-4. We show that...

  • Scalar-isovector K¯ production close to threshold. Dzyuba, A.; Kleber, V.; Büscher, M.; Chernyshev, V.; Dymov, S.; Fedorets, P.; Grishina, V.; Hanhart, C.; Hartmann, M.; Hejny, V.; Kondratyuk, L.; Koptev, V.; Kulessa, P.; Maeda, Y.; Mersmann, T.; Mikirtychyants, S.; Nekipelov, M.; Prasuhn, D.; Schleichert, R.; Sibirtsev, A. // European Physical Journal A -- Hadrons & Nuclei;Aug2006, Vol. 29 Issue 2, p245 

    The reaction pp → dK +¯ has been investigated at excess energies Q = 47.4 and 104.7MeV above the K +¯ threshold at COSY Jülich. Coincident dK+ pairs were detected with the ANKE spectrometer, and subsequently ∼ 2000 events with a missing ¯ invariant mass were identified,...

  • Shrinking the `Universal Sensor'.  // R&D Magazine;Aug99, Vol. 41 Issue 9, ps-53 

    Reports that the time-of-flight spectrometer (TOF-MS) being developed by researchers at Baltimore, Maryland can fit into a package about the size of a shoebox. Several enhancements in TOF-MS; Comparison of TOF-MS with traditional mass spectrometry; Size and weight highlights; Applications for...

  • The new JET 2.5-MeV neutron time-of-flight spectrometer. Elevant, T.; Belle, P. v.; Grosshög, G.; Hoek, M.; Jarvis, O. N.; Olsson, M.; Sadler, G. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4586 

    A major upgrade of the JET 2.5-MeV neutron time-of-flight spectrometer has been completed. The improvement has permitted ion temperature measurements for Maxwellian deuterium plasmas with T[sub i] > 4 keV to be obtained in 0.5-s intervals. By combining observations of neutron and x-ray energy...

  • X-ray luminosity time-of-flight spectrometer for laser-produced plasmas. Naik, P. A.; Gupta, P. D.; Kumbhare, S. R. // Review of Scientific Instruments;Jul1988, Vol. 59 Issue 7, p1076 

    A simple and compact x-ray luminosity time-of-flight spectrometer for measurements of the velocity distribution of highly charged ions in laser-produced plasmas is presented. The spectrometer is based on making time- and space-resolved measurements of x-ray line emission from these ions in the...

  • Quasielastic high-resolution direct geometry TOF spectrometers. at steady-state reactors and at spallation sources. Lechner, R.E. // Applied Physics A: Materials Science & Processing;Dec2002 Supplement, Vol. 74 Issue 6, ps151 

    Intensity optimization at a given resolution of direct-geometry multi-chopper time-of-flight (MTOF) spectrometers for high-resolution QENS experiments is discussed in view of further developing this technique to allow moreefficient measurements and more-extensive variation of the time scales, on...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics