TITLE

Synchronization of multiple spark-gap switches by a transmission line transformer

AUTHOR(S)
Liu, Z.; Yan, K.; Pemen, A. J. M.; Winands, G. J. J.; Van Heesch, E. J. M.
PUB. DATE
November 2005
SOURCE
Review of Scientific Instruments;Nov2005, Vol. 76 Issue 11, p113507
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A transmission line transformer (TLT)-based multiple-switch circuit topology was recently proposed for pulsed-power generation. By means of a TLT, multiple spark-gap switches can be synchronized in a short time (ns). It is attractive to be used to design a long-lifetime repetitive large pulsed-power source (100 kW, 1 kHz) for various kinds of applications, such as corona plasma-induced gas cleaning. To gain insight into the synchronization principle and switching behavior of the individual switch, an equivalent circuit model was developed and an experimental setup with two spark-gap switches and a two-stage TLT has been constructed. We observed that in terms of switching currents, the two switches can be synchronized within 2–3 ns. The equivalent circuit model approximately fits the experimental results.
ACCESSION #
19215118

 

Related Articles

  • Current Transformer Terminal Blocks are Ready for Energy. BENTLER, HARRY; SAPPE, ALAN // POWERGRID International;Dec2009, Vol. 14 Issue 12, p50 

    The article offers information on terminal blocks for current transformers (CT) and potential transformers. CT and potential transformers offer isolation from high-voltage systems and allow grounding of secondary circuits to ensure safety. Disconnect terminal blocks with knife-style disconnect...

  • Magnetization and Primary Injection Test of Current Transformer for Protective Relaying. TSADO, Jacob // Leonardo Journal of Sciences;Jul-Dec2011, Vol. 10 Issue 19, p1 

    Emphasis is placed on the ability of current transformers to provide accurate operating current at normal system operation and other system disturbance to protective relay systems in high voltage power systems. This paper presents the results of a laboratory investigation of magnetization and...

  • Error reduction of phasor measurement unit data considering practical constraints. Chatterjee, Paroma; Pal, Anamitra; Thorp, James S.; De La Ree Lopez, Jaime; Centeno, Virgilio A. // IET Generation, Transmission & Distribution;2018, Vol. 12 Issue 10, p2332 

    Wide area measurement system relies on phasor measurement unit (PMU) data to monitor, protect, and control high voltage transmission networks. However, errors in instrument transformers (ITs) located at the inputs of a PMU can significantly degrade its output quality. This study proposes two...

  • Exploring Current Transformer Applications. Hays, William // Power Electronics Technology;Jun2002, Vol. 28 Issue 6, p30 

    Discusses the applications of current transformers. Performance of circuit control; Measurement of current for power measurement and control; Performance of roles for safety protection and current limiting; Calibration of the device that monitors output voltage to produce the desired results...

  • Don't be left short by current transformers. Borland, Jerry R. // EC&M Electrical Construction & Maintenance;Oct99, Vol. 98 Issue 11, p62 

    Focuses on current transformers. Basic design of CT; Basic functions performed by CT; Comparison of the window, bar, and wound types of CT; Accuracy rating and applications.

  • Design and experimental performance of a pulsed power transformer for liner implosion experiments. Yugami, N.; Mizuguchi, Y.; Shimoura, K.; Imasaki, K.; Miyamoto, S.; Nakai, S.; Yamanaka, C. // Review of Scientific Instruments;Jun88, Vol. 59 Issue 6, p910 

    A pulse power transformer has been designed and tested for pulsed power driven Z-pinch experiments. The transformer has reduced the output impedance of a pulsed power machine ‘‘Reiden IV’’ from 2 to 0.02 Ω. The parasitic inductance at the water/vacuum insulator is...

  • Hybrid winding configuration in high-current injection transformers based on EMC issues. Heydari, H.; Faghihi, F. // IET Electric Power Applications;May2009, Vol. 3 Issue 3, p187 

    In designing high-current injection transformers (CITs), many factors need to be considered for its compatibility with the internal and external propagation and generation of disturbances within electromagnetic environment, i.e. the magnetic leakage field must be reduced to a level that will...

  • Nanosecond rise time air-core current transformer for long-pulse current measurement in pulsed power. Shukla, R.; Shyam, A.; Chaturvedi, S.; Kumar, R.; Lathi, D.; Chaudhary, V.; Verma, R.; Debnath, K.; Sharma, S.; Sonara, J.; Shah, K.; Adhikary, B. // Review of Scientific Instruments;Dec2005, Vol. 76 Issue 12, p125107 

    A slow-wave delay line type air-core (nonmagnetic Nylon former) current transformer fabricated using silver epoxy for the measurement of currents of long pulse durations and few nanoseconds rise times is reported in this article. The advantage of using silver epoxy is that it fills all the voids...

  • MEASUREMENT AND ESTIMATION OF VERY FAST RADIATED ELECTROMAGNETIC FIELDS IN A 245KV GAS INSULATED SUBSTATION. Rao, J. V. G. Rama; Amarnath, J.; Kamakshaiah, S. // Journal of Engineering & Applied Sciences;2010, Vol. 5 Issue 4, p56 

    The transient high frequency electric and magnetic fields are generated in GIS systems during switching operations. In the present work, the measurement of magnetic fields and electric fields have been carried out at various locations of 245KV GIS (Gas insulated substation) during closing...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics