Establishing a chromium-reactor design for measuring δ2H values of solid polyhalogenated compounds using direct elemental analysis and stable isotope ratio mass spectrometry

AUTHOR(S)
Armbruster, Wolfgang; Lehnert, Katja; Vetter, Walter
PUB. DATE
December 2005
SOURCE
Analytical & Bioanalytical Chemistry;Dec2005, Vol. 384 Issue 1, p237
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
2H/1H isotope ratios of polyhalogenated compounds were determined by elemental analysis and isotope ratio mass spectrometry (EA-IRMS). Initial measurements with standard EA-IRMS equipment, which used high-temperature pyrolysis to convert the organic compounds into hydrogen, did not achieve significant signals for polychlorinated pesticides and related compounds, presumably due to the formation of HCl instead of hydrogen. To reverse this problematic reaction, a chromium reactor was incorporated into the element analyzer system, which scavenged Cl, forming chromium chloride and releasing hydrogen again in the form of H2. The optimized system therefore allowed the δ2H values of polyhalogenated compounds to be determined. A quality assurance program was developed based on several parameters. (i) Each compound was analyzed using a sequence of five injections, where the first measurement was discarded. (ii) Recovery of H (when calculated relative to acetanilide) had to be >90% for all replicates in a sequence. (iii) All δ-values within a sequence had to vary by less than 10‰. (iv) Results had to be reproducible on another day with a different sample scheme. Once this reproducibility had been established, variabilities in the δ2H values of organohalogen standards were investigated using the technique. The highest δ2H value of +75‰ was found for o,p´-DDD, whereas the strongest depletion in deuterium was found for Melipax (–181‰). The most important results for comparable compounds were as follows. DDT-related compounds gave δ2H values of between +59 and +75‰ (technical DDT, o, p´- and p,p´-DDD) or in the range of approximately −1‰, indicative of the different sources/methods of producing this compound. Four HCH isomers from the same supplier showed relatively similar hydrogen isotope distributions, whereas two lindane (γ–HCH) standards from other sources had 39‰ less deuterium. This difference is likely due to different purification steps during the isolation of pure lindane from the technical HCH mixture. An even greater difference was observed between the δ2H values of Toxaphene (US product dating from 1978) and Melipax (product from the former East Germany, dating from 1979), which gave δ2H values of –101‰ and –181‰, respectively, meaning that both products were easily distinguished via δ2H-IRMS. Fractioning of hydrogen isotopes in the atmospheric water cycle was suggested as one reason for the different values. In this theory, the water (which had different δ2H values depending on where it was taken from) was incorporated during the biosynthesis of camphene, which is the natural product used to produce both products. These results indicate that hydrogen isotope-specific analysis can be a valuable tool for tracing the origins of a compound in certain cases.
ACCESSION #
19203942

 

Related Articles

  • Spectroscopy of Superheavy Hydrogen Isotopes in Stopped-Pion Absorption by Nuclei. Gurov, Yu. B.; Aleshkin, D. V.; Behr, M. N.; Lapushkin, S. V.; Morokhov, P. V.; Pechkurov, V. A.; Poroshin, N. O.; Sandukovsky, V. G.; Tel'kushev, M. V.; Chernyshev, B. A.; Tschurenkova, T. D. // Physics of Atomic Nuclei;Mar2005, Vol. 68 Issue 3, p491 

    The structure of levels of superheavy hydrogen isotopes 4–6H is analyzed on the basis of a record statistics of experimental data on the absorption of negatively charged pions by light nuclei. Qualitatively new experimental data are obtained for the spectroscopy of the superheavy hydrogen...

  • Detection of hydrogen isotope atoms by mass spectrometry combined with resonant ionization. Yorozu, M.; Okada, Y.; Endo, A. // Applied Physics B: Lasers & Optics;1999, Vol. 69 Issue 2, p129 

    Abstract. We examined the application of mass spectrometric methods using resonant ionization by a tunable laser and proposed its use for analyzing hydrogen isotopes. We conducted resonance ionization mass spectrometry (RIMS) to detect gas-phase hydrogen isotope atoms. The ionization efficiency...

  • Introduction of hydrogen isotopes into Maraviroc and mass-spectrometric study of deuterium distribution. Shevchenko, V.; Nagaev, I.; Myasoedov, N. // Radiochemistry;Apr2009, Vol. 51 Issue 2, p175 

    Maraviroc labeled with hydrogen isotopes was prepared. Maraviroc molecules contain, on the average, more than four atoms of hydrogen isotopes. The isotope distribution was studied by mass spectrometry. If the amount of deuterium incorporated in Maraviroc molecule is taken as 100%, the triazole...

  • EXPERIMENTAL EVIDENCES OF THE INFLUENCE OF NITROGEN GAS ON THE TRIMER IONS IN LOW RESOLUTION MASS SPECTROMETRY OF HYDROGEN ISOTOPES. Bidică, N.; Bulubașa, G. // Progress of Cryogenics & Isotopes Separation;2012, Vol. 15 Issue 1, p5 

    This paper presents experimental results regarding the behaviour of triatomic (trimer) ions formed in the electron impact ion source of a mass spectrometer in the presence of high concentrations of nitrogen gas. These results were obtained during an experimental work performed in order to find...

  • Use of methyl p-toluenesulfonate labeled with hydrogen isotopes as a donor of methyl group. Shevchenko, V.; Nagaev, I.; Myasoedov, N. // Radiochemistry;Apr2009, Vol. 51 Issue 2, p178 

    Methyl p-toluenesulfonates TosOCH23H and TosOCH22H containing, on the average, 0.5 atom of hydrogen isotope per molecule were prepared by catalytic dehalogenation of bromomethyl p-toluenesulfonate TosOCH2Br with tritium and deuterium. Mass-spectrometric analysis showed that the label is fully...

  • Hydrogen Isotope Labeling of PTC124. Shevchenko, V. P.; Nagaev, I. Yu.; Myasoedov, N. F. // Radiochemistry;Feb2010, Vol. 52 Issue 1, p95 

    PCT124 labeled with hydrogen isotopes was prepared. For efficient isotope labeling of this compound, the reaction should be performed under severe conditions. With additional supports, the isotope exchange could be performed at 260-270°C. Under these conditions, the labeled compound with the...

  • THEORETICAL AND EXPERIMENTAL RESEARCH OF THE OVERLAP EFFECTS IN THE QUADRUPOLE MASS SPECTROMETRIC ANALYSIS OF HYDROGEN ISOTOPES MIXTURES. Stefanescu, Alina; Bidica, Nicolae; Bornea, Anisia; Cristescu, Ion; Varlam, Mihai; Stefanescu, Ioan // Progress of Cryogenics & Isotopes Separation;2011, Vol. 14 Issue 1, p5 

    To measure the concentration of hydrogen isotopic species in gaseous streams of hydrogen isotopes mixtures sampled from a cryogenic separation column, we intend to use a GSD 320 quadrupole mass spectrometer. In order to consistently generate measurements of high precision and reliability, an...

  • Histidine Hydrogen-Deuterium Exchange Mass Spectrometry for Probing the Microenvironment of Histidine Residues in Dihydrofolate Reductase. Miyagi, Masaru; Qun Wan; Ahmad, Md. Faiz; Gokulrangan, Giridharan; Tomechko, Sara E.; Bennett, Brad; Dealwis, Chris // PLoS ONE;2011, Vol. 6 Issue 2, p1 

    Background: Histidine Hydrogen-Deuterium Exchange Mass Spectrometry (His-HDX-MS) determines the HDX rates at the imidazole C2-hydrogen of histidine residues. This method provides not only the HDX rates but also the pKa values of histidine imidazole rings. His-HDX-MS was used to probe the...

  • First continuous shipboard δO and δD measurements in sea water by diffusion sampling-cavity ring-down spectrometry. Munksgaard, N.; Wurster, C.; Bass, A.; Zagorskis, I.; Bird, M. // Environmental Chemistry Letters;Sep2012, Vol. 10 Issue 3, p301 

    Combined measurements of salinity and the oxygen/hydrogen stable isotope composition of marine waters can characterise processes such as freshwater mixing, evaporation, precipitation and sea-ice formation. However, stable isotope data with high spatial and temporal resolution are necessary for a...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics