TITLE

Geometric Distortion in Structural Magnetic Resonance Imaging

AUTHOR(S)
Wang, Deming; Doddrell, David M.
PUB. DATE
January 2005
SOURCE
Current Medical Imaging Reviews;2005, Vol. 1 Issue 1, p49
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Geometric distortion, an undesirable image artifact, is an inferior aspect associated with magnetic resonance imaging (MRI). Although slight distortions in MR images often have no consequences in reaching clinical conclusions, geometric distortions can make significant differences in certain MR applications such as, for example, stereotactic localization in radio-surgery and MR image-guided biopsy. In this article, geometric distortion in structural MRI is reviewed. It begins with a brief discussion of various sources that can cause geometric distortion in structural MRI, followed by a review of the apparatus and methods that have been developed for the measurement and characterization of the geometric distortion in MRI. The paper will then focus on a novel phantom-based technique that has been developed recently by the authors. This technique can provide a comprehensive and complete measurement of the geometric distortion in 3-dimensions with unprecedented details and accuracy. The major outcomes of a comprehensive study on the geometric distortion in representative clinical MR scanners, carried out recently using this technique, will be discussed. The article will also include a discussion of various correction methods that have been developed for correcting geometric distortion in MRI.
ACCESSION #
19064599

 

Related Articles

  • Percutaneous Disc Decompression with Nucleoplasty-Volumetry of the Nucleus Pulposus Using Ultrahigh-Field MRI. Kasch, Richard; Mensel, Birger; Schmidt, Florian; Drescher, Wolf; Pfuhl, Ralf; Ruetten, Sebastian; Merk, Harry R.; Kayser, Ralph // PLoS ONE;Jul2012, Vol. 7 Issue 7, p1 

    Purpose: To evaluate changes in nucleus pulposus volume as a potential parameter for the effects of disc decompression. Methods: Fifty-two discs (T8 to L1) were extracted from 26 pigs and separated into thoracic (T8 to T11) and thoracolumbar discs (T12 to L1). The discs were imaged using 7.1...

  • Magnetic Resonance Imaging. Torpy, Janet M.; Lynm, Cassio; Glass, Richard M. // JAMA: Journal of the American Medical Association;12/16/2009, Vol. 302 Issue 23, p2614 

    The article offers information on magnetic resonance imaging (MRI) technique used in medicine. MRI uses the magnetic fields to provide images of body tissues which helped in the diagnosis of certain conditions in adults and children. These parts of the body where MRI can be used include the...

  • Effect of a 1.5 Tesla Magnetic Field on Greenfield Filters in Vitro and in Dogs. Williamson, Michael R.; McCowan, Timothy C.; Walker, Craig W.; Ferris, Ernest J. // Angiology;Dec1988, Vol. 39 Issue 12, p1022 

    The authors have tested four Greenfield filters for deflection in a 1.5 Tesla magnetic field and found large variations in the amount of deflection among filters. They also placed two filters in dogs and checked the filter for migration by taking radiographs before and after magnetic resonance...

  • An Adaptive Fuzzy C-Means Algorithm for Improving MRI Segmentation. Zanaty, Elnomery Allam // Open Journal of Medical Imaging;Dec2013, Vol. 3 Issue 4, p125 

    In this paper, we propose new fuzzy c-means method for improving the magnetic resonance imaging (MRI) segmentation. The proposed method called "possiblistic fuzzy c-means (PFCM)"which hybrids the fuzzy c-means (FCM) and possiblistic c-means (PCM) functions. It is realized by modifying the...

  • Comparing Saddle, Slotted-tube and Parallel-plate Coils for Magnetic Resonance Imaging. Nespor, D.; Bartusek, K.; Dokoupil, Z. // Measurement Science Review;2014, Vol. 14 Issue 3, p171 

    The paper is concerned with a comparison of the properties of RF coils of three configurations for MRI measurements on small animals. In comparison with the classical saddle coil the proposed modification of slotted-tube coil exhibits identical homogeneity of B1 field in a larger space. The...

  • Improved in vivo detection of cortical lesions in multiple sclerosis using double inversion recovery MR imaging at 3 Tesla. Simon, Birgit; Schmidt, Stephan; Lukas, Carsten; Gieseke, Jürgen; Träber, Frank; Knol, Dirk L.; Willinek, Winfried A.; Geurts, Jeroen J. G.; Schild, Hans H.; Barkhof, Frederik; Wattjes, Mike P. // European Radiology;Jul2010, Vol. 20 Issue 7, p1675 

    To investigate the impact of a higher magnetic field strength of 3 Tesla (T) on the detection rate of cortical lesions in multiple sclerosis (MS) patients, in particular using a dedicated double inversion recovery (DIR) pulse sequence. Thirty-four patients with clinically isolated syndromes or...

  • High-field human imaging. Gulani, Vikas // Applied Radiology;Jan2005 Supplement, Vol. 34, p75 

    The attraction of high magnetic-field imaging is a theoretical linear increase in signal-to-noise ratio with field strength. However, maximal benefit is not always achieved due to difficulties of imaging at higher fields, such as T1 lengthening. T2/T2* shortening, specific absorption rate...

  • Recent Patents on Magnetic Resonance Imaging Sequences in Presence of Static Magnetic Field in-homogeneity. Placidi, Giuseppe; Franchi, Danilo; Maurizi, Alfredo; Sotgiu, Antonello // Recent Patents on Biomedical Engineering;Jan2009, Vol. 2 Issue 1, p73 

    Abstract: In Magnetic Resonance Imaging (MRI), magnetic field spatial variations are used to codify the signal. The presence of static magnetic field in-homogeneities introduces distortions and artifacts in the images. To reduce these effects, magnets with very high magnetic field homogeneity in...

  • Square-Cut: A Segmentation Algorithm on the Basis of a Rectangle Shape. Egger, Jan; Kapur, Tina; Dukatz, Thomas; Kolodziej, Malgorzata; Zukic, D�enan; Freisleben, Bernd; Nimsky, Christopher // PLoS ONE;Feb2012, Vol. 7 Issue 2, p1 

    We present a rectangle-based segmentation algorithm that sets up a graph and performs a graph cut to separate an object from the background. However, graph-based algorithms distribute the graph's nodes uniformly and equidistantly on the image. Then, a smoothness term is added to force the cut to...

Share

Other Topics