TITLE

Investigation of compound-independent calibration and partial molecular formula determination by gas chromatography–atomic-emission detection for characterisation of organophosphorus and organosulfur agents related to the chemical weapons convention

AUTHOR(S)
Juillet, Yannick; Gibert, Edmond; Bégos, Arlette; Bellier, Bruno
PUB. DATE
November 2005
SOURCE
Analytical & Bioanalytical Chemistry;Nov2005, Vol. 383 Issue 5, p848
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Atomic-emission detection (AED) is a technique particularly-well suited to screening complex samples for multiple compounds containing heteroatoms such as phosphorus, sulfur, or nitrogen, which are especially relevant in verification of chemical disarmament. Among other GC detectors, AED has unique characteristics such as compound-independent calibration and possible raw-formula determination. Because contradictory results have been reported on these points, we set up a study with the objectives not only of applying these techniques to chemical weapons convention-related chemicals but of determining under which conditions they would yield satisfactory results. The extensive data collected in this study are evidence that the response of the detector, particularly for the phosphorus line, is very dependent on the molecular mass and concentration of the chemicals analysed whereas molecular structure seems to have less effect on the AED signal. Most interestingly, compound-independent calibration and subsequent partial molecular formula determination usually seem satisfactory when the reference compounds used to calibrate the system have GC retention times and molecular masses close to those of the unknown analytes (whose molecular mass may be determined by GC–CI-MS). We therefore suggest the use of a reference set of compounds covering a large chromatographic window, which enables the selection, within this set, of the most appropriate reference compound for calibration and for determination of the raw formula of an unknown analyte. For optimal performance, the use of a new discharge tube is also recommended.
ACCESSION #
18755142

 

Related Articles

  • Chemical weapons. Ferner, R.E.; Rawlins, M.D. // BMJ: British Medical Journal (International Edition);3/25/89, Vol. 298 Issue 6676, p767 

    Focuses on the chemical weapons used in the Middle East. Effects of the organophosphorus nerve agents on acetylcholinesterase; Manifestation of local irritants; Discussions on the 1925 Geneva protocol.

  • Derivatization of organophosphorus nerve agent degradation products for gas chromatography with ICPMS and TOF-MS detection. Richardson, Douglas D.; Caruso, Joseph A. // Analytical & Bioanalytical Chemistry;Jun2007, Vol. 388 Issue 4, p809 

    Separation and detection of seven V-type (venomous) and G-type (German) organophosphorus nerve agent degradation products by gas chromatography with inductively coupled plasma mass spectrometry (GC–ICPMS) is described. The nonvolatile alkyl phosphonic acid degradation products of interest...

  • Quantitation of Metabolites of the Nerve Agents Sarin, Soman, Cyclohexylsarin, VX, and Russian VX in Human Urine Using Isotope-Dilution Gas Chromatography—Tandem Mass Spectrometry. Barr, John R.; Driskell, W. Jack; Aston, Linda S.; Martinez, Rodolfo A. // Journal of Analytical Toxicology;Jul/Aug2004, Vol. 28 Issue 5, p372 

    Discusses the development of an isotope-dilution gas chromatography-tandem mass spectrometric method for quantitating the urinary metabolites of the organophosphorus nerve agents sarin (Gb), soman (GD), VX, Russian VX (RVX) and cyclohexylsarin (GF). Limits of detection; Threat of...

  • Sarin's poisonous effect seen in Syrian citizens. Schep, Leo // New Zealand Doctor;9/25/2013, p36 

    The article reports on the fatal effect of organophosphate compounds on human's health as depicted on the alleged use of chemical weapons by the Syrian government to its own citizens in 2013. It highlights the effects of organophosphate nerve agents which include miosis, urination, and...

  • A new polysiloxane coating on QCM sensor for DMMP vapor detection. Xiaosong Du; Zhidong Wang; Jia Huang; Silu Tao; Xianzhong Tang; Yadong Jiang // Journal of Materials Science;Nov2009, Vol. 44 Issue 21, p5872 

    A new material-poly{methyl [3-(2-hydroxyl, 4,6-bistrifluoromethyl)phenyl]propylsiloxane} (PMTFMPS), which was sensitive to toxic organophosphate vapor, was synthesized via O-alkylation, claisen rearrange reaction and hydrosilylation reaction. The polymer was coated on quartz crystal microbalance...

  • One is it all it takes. Mullins, Justin // New Scientist;09/06/97, Vol. 155 Issue 2098, p7 

    Reports on the development of supersensitive sensor that will protect troops and civilians against attack from biological and chemical weapons. Biosensor's reliance on the principle that human body protects itself by producing antibodies that bind to specific antigens; Details of the sensor's...

  • A better `10-foot pole'. Kren, Lawrence // Machine Design;11/18/99, Vol. 71 Issue 22, p46 

    Provides information on Polychromator, a handheld detector that could help soldiers identify the contents of a toxic plume that employs the silicon microelectromechanical systems (MEMS)-controlled optical grating. Information on MEMS-controlled optical grating.

  • Seeing through steel. Koucky, Sherri; Mraz, Stephen // Machine Design;05/18/2000, Vol. 72 Issue 10, p30 

    Introduces a portable isotopic neutron spectroscopy system developed by scientists at Idaho National Engineering and Environmental Laboratory that tells what is inside abandoned chemical weapons without having to open them up. Features of the system; Elements of each warhead fill.

  • Micro-scale analytical plasmas for liquid chromatography detection. Venzie, Jacob L.; Marcus, R. Kenneth // Analytical & Bioanalytical Chemistry;Jan2005, Vol. 381 Issue 1, p96 

    Discusses the use of micro-scale plasmas for liquid chromatography detection. Requirements of chromatographers for detectors; Features of the microwave induced plasma-atomic emission detector; Factors which affect the functions of liquid chromatography microplasma detector.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.