TITLE

Peritoneal clearance of creatinine and inulin during dialysis in dogs: Effect of splanchnic vasodilators

AUTHOR(S)
Felt, Jim; Richard, Cathy; McCaffrey, Christine; Levy, Mortimer
PUB. DATE
October 1979
SOURCE
Kidney International;Oct1979, Vol. 16 Issue 4, p459
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The peritoneal clearance of creatinine and inulin during isotonic peritoneal dialysis was studied in dogs before and after the administration of two vasodilators: isoproterenol and glucagon. One-liter exchanges with 15-min dwell times were used. Blood flow in the superior mesenteric artery was recorded with an electromagnetic flow probe and used as an index for total splanchnic flow. Intravenous isoproterenol (2.4 μg/min) increased blood flow by 88%, but did not alter peritoneal clearances. When isoproterenol was given i.p. (0.5 μg/ml dialysis fluid), blood flow increased by 81%, and inulin clearance rose by 26.8% (2.06 ± 0.18 to 2.61 ± 0.23 ml/min; P < 0.05). Creatinine clearance increased by 17.5%, from 10.94 ± 0.32 to 12.85 ± 0.34 ml/min (P < 0.05). When blood flow was returned to control levels with a clamp, clearances also returned to control levels. Glucagon given i.p. (1.0 μg/ml) had no effect on any measured variable. Glucagon given i.e. at 10 μg/min caused blood flow to rise by 81% and inulin .clearance to rise by 25% from 1.88 ± 0.16 to 2.35 ± 0.19 ml/min (P < 0.05). Creatinine clearance did not change. When blood flow was kept constant with a clamp, inulin clearance remained at control levels. Vasodilators seem to exercise two effects in augmenting clearance of small and middle-sized molecules: a direct permeability effect and a blood-flow related effect, possibly in increasing the surface area available for exchange and/or increasing permeability of the capillary endothelium.
ACCESSION #
17678122

 

Related Articles

  • Effect of dialysate volume on peritoneal dialysis kinetics. Goldschmidt, Zvi H.; Pote, Harry H.; Katz, Murray A.; Shear, Leroy // Kidney International;Mar1974, Vol. 5 Issue 3, p240 

    The effect of peritoneal dialysate volume on the rates of transperitoneal urea and creatinine equilibration was determined over a 120-min sampling period. Equilibration half-lime (t½) was prolonged when volume was increased from 1 to 2 to 3 liters. Some data suggest this delay was not...

  • Determinants of low clearances of small solutes during peritoneal dialysis. Nolph, Karl D.; Popovich, Robert P.; Ghods, Ahad J.; Twardowski, Zbylut // Kidney International;Feb1978, Vol. 13 Issue 2, p117 

    Discusses evidence suggesting limitations on small solute clearances independent of dialysis solution flow rate and perhaps related to total membrane resistance and/or limited peritoneal capillary blood flow. Possible limitations on small solute clearances secondary to total membrane resistance;...

  • Restoration of peritoneal integrity after withdrawal of peritoneal dialysis: characteristic features of the patients at risk of encapsulating peritoneal sclerosis. Otsuka, Yasushi; Nakayama, Masaaki; Ikeda, Masato; Sherif, Ali M.; Yokoyama, Keitaro; Yamamoto, Hiroyasu; Kawaguchi, Yoshindo // Clinical & Experimental Nephrology;Dec2005, Vol. 9 Issue 4, p315 

    Background. The epidemiological characteristics of encapsulating peritoneal sclerosis (EPS), such as its high incidence in patients with long-term peritoneal dialysis (PD) treatment, and the onset of EPS after patients are switched to hemodialysis (HD) may indicate an activated pathological...

  • Effects of exercise on vasodilatory capacity in endurance- and resistance-trained men. Baynard, Tracy; Miller, Wayne C.; Fernhall, Bo // European Journal of Applied Physiology;Mar2003, Vol. 89 Issue 1, p69 

    To determine vasodilatory responsiveness we measured forearm blood flow (FBF) following reactive hyperemia (RH), prior to and following a bout of maximal aerobic exercise in endurance- (n=14) and resistance-trained men (n=10). Both groups were similar in height, body mass, and percentage body...

  • Tidal peritoneal dialysis: Comparison of different tidal regimens and automated peritoneal dialysis. Juergensen, Peter H.; Murphy, A. Lola; Pherson, Kathy A.; Kliger, Alan S.; Finkelstein, Fredric O. // Kidney International;Jun2000, Vol. 57 Issue 6, p2603 

    Tidal peritoneal dialysis: Comparison of different tidal regimens and automated peritoneal dialysis. Background. The National Kidney Foundation Dialysis Outcomes Quality Initiative (DOQI) clinical practice guidelines have suggested minimal weekly Kt/V urea and creatinine clearance goals for...

  • Clinical outcome of pediatric patients on peritoneal dialysis under adequacy control. Hölttä, Tuula; Rönnholm, K.; Jalanko, Hannu; Holmberg, Christer // Pediatric Nephrology;Sep2000, Vol. 14 Issue 10/11, p889 

    Clinical outcome under adequacy control was studied in 10 pediatric patients under 5 years and 11 patients over 5 years of age on continuous peritoneal dialysis (PD). Outcome was compared between the age groups and with our previous results in patients under 5 years of age. Peritoneal...

  • A high-fat meal impairs muscle vasodilatation response to mental stress in humans and Glu27 β2-adrenoceptor polymorphism. Gowdak, Marcia M. G.; Laterza, Mateus C.; Rondon, Maria Urbana P. B.; Trombetta, Ivani C.; Pereira, Alexandre C.; Krieger, José Eduardo; Negrão, Carlos Eduardo // Lipids in Health & Disease;2010, Vol. 9, p55 

    Background: Forearm blood flow responses during mental stress are greater in individuals homozygous for the Glu27 allele. A high-fat meal is associated with impaired endothelium-dependent dilatation. We investigated the impact of high-fat ingestion on the muscle vasodilatory responses during...

  • Effects of ageing and fitness on skin-microvessel vasodilator function in humans. Tew, Garry A.; Klonizakis, Markos; Saxton, John M. // European Journal of Applied Physiology;May2010, Vol. 109 Issue 2, p173 

    The impact of cardiopulmonary fitness (VO(2max)) on the age-related decline in skin-microvessel vasodilator function has not been fully established and the inter-relationships among different measures of microvascular vasodilator function are unknown. We used laser Doppler flowmetry to assess...

  • Using skin temperature gradients or skin heat flux measurements to determine thresholds of vasoconstriction and vasodilatation. House, James R.; Tipton, Michael J. // European Journal of Applied Physiology;Oct2002, Vol. 88 Issue 1/2, p141 

    Forearm–fingertip skin temperature differentials (Tsk-diff) are used to indicate vasomotor tone, vasoconstriction defined as having occurred when Tsk-diff≥4°C (Sessler et al. 1987, 1988a, b). This study was conducted to determine whether Tsk-diff or finger pad heat flux (HF) can...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library