TITLE

Performance of polymethyl pentene oxygenators for neonatal extracorporeal membrane oxygenation: a comparison with silicone membrane oxygenators

AUTHOR(S)
Khoshbin, Espeed; Westrope, Claire; Pooboni, Suneel; Machin, David; Killer, Hilliary; Peek, Giles J.; Sosnowski, Andrzej W.; Firmin, Richard K.
PUB. DATE
May 2005
SOURCE
Perfusion;May2005, Vol. 20 Issue 3, p129
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Objective: To review the performance of polymethyl pentene versus silicone oxygenators in terms of efficiency in priming and oxygenation, oxygenator resistance, requirements for coagulation proteins and consumption of blood products, for neonatal extracorporeal membrane oxygenation (ECMO) patients. Study design: Forty consecutive neonates were selected retrospectively pre- and post-introduction of the new polymethyl pentene (PMP) oxygenators. They formed two equal groups. After calculation of the sample size, data were collected from ELSO registry forms and patient records. Results were analysed using parametric and non-parametric tests. Results: Neonatal PMP (N-PMP) oxygenators were smaller, faster and easier to prime. They were less efficient than silicone oxygenators, especially in carbon dioxide elimination, and, therefore, required higher sweeps. The preservation of coagulation proteins was significantly better, but there was no reduction in the consumption of blood products, despite having less than half the surface area and significantly lower blood path resistance. Conclusion: Small PMP oxygenators (Medos Hilite 800 LT) provide adequate gas exchange and offer technical advantages in terms of more efficient priming, reduced haemodynamic resistance and better control and preservation of coagulation proteins than silicone oxygenators.
ACCESSION #
17360062

 

Related Articles

  • A potential propensity for failure secondary to clot embolism in neonatal ECMO. Khoshbin, Espeed; Machin, David; Killer, Hilliary; Peek, Giles J; Sosnowski, Andrzej W; Firmin, Richard K // Perfusion;May2005, Vol. 20 Issue 3, p177 

    Objective: To report a single case of oxygenator failure caused by clot embolism originating from the bladder; and to discuss some preventative options. Case report: A 2.5 kg neonate with a diagnosis of influenza A received veno-arterial (V–A) extracorporeal membrane oxygenation (ECMO)...

  • Should Zelen pre-randomised consent designs be used in some neonatal trials? Allmark, Peter // Journal of Medical Ethics;Aug99, Vol. 25 Issue 4, p325 

    My aim is to suggest that there is a case for using a randomised consent design in some neonatal trials. As an example I use the trials of extracorporeal membrane oxygenation (ECMO) in neonates suffering pulmonary hypertension. In some trials the process of obtaining consent has the potential to...

  • ...Except in England?  // AIMS Journal;2003, Vol. 15 Issue 1, p17 

    Comments on key issues concerning the medical practice of cooling babies to reduce brain damage for those who have suffered a lack of oxygen. Considerations in the administration of extracorporeal membrane oxygenation (ECMO); Establishment of an independent data-monitoring committee who were...

  • Looking beyond survival rates: neurological outcomes after extracorporeal life support. Brown, Kate; MacLaren, Graeme; Marino, Bradley; Brown, Kate L; Marino, Bradley S // Intensive Care Medicine;Oct2013, Vol. 39 Issue 10, p1870 

    In this article, the authors focus on survival rates after using extracorporeal membrane oxygenation (ECMO) for neonatal respiratory failure. They refer to a study by researcher A. Polito et al. in 2013, according to which 1,412 neonates experienced a neurological complication based on the ECMO...

  • Developmental outcome in newborn infants treated for acute respiratory failure with extracorporeal membrane oxygenation: present experience. Khambekar, K.; Nichani, S.; Luyt, D. K.; Peek, G.; Firmin, R. K.; Field, D. J.; Pandya, H. C. // Archives of Disease in Childhood -- Fetal & Neonatal Edition;Jan2006, Vol. 91 Issue 1, pF21 

    Objective: To describe the later health status of newborn infants who received extracorporeal membrane oxygenation (ECMO) for acute respiratory failure in the era after the UK ECMO trial. Design: Prospective follow up study of newborn infants who received ECMO at a single centre between January...

  • A comparison of radiographic signs of pulmonary inflammation during ECMO between silicon and poly-methyl pentene oxygenators. Khoshbin, Espeed; Dux, Anthony E. W.; Killer, Hilliary; Sosnowski, Andrzej W.; Firmin, Richard K.; Peek, Giles J. // Perfusion;Jan2007, Vol. 22 Issue 1, p15 

    Introduction: The inflammatory response caused by extracorporeal membrane oxygenation (ECMO) is clearly visible within the first 24 h of cannulation. The inflammatory process affects all areas of the lung, even areas previously spared by the primary disease. Objective: To compare the change in...

  • Compact intra- and extracorporeal oxygenator developments. Cattaneo, Giorgio; Strauß, Andreas; Reul, Helmut // Perfusion;Jul2004, Vol. 19 Issue 4, p251 

    For patients with acute lung failure, mechanical ventilation entails the risk of lung tissue damage due to high oxygen pressure and concentration. Membrane oxygenation for one to two weeks can rest the lungs due to decreased ventilation parameters, representing a potential bridge to recovery,...

  • How to resuscitate the depressed newborn. Danon, Ardis // RN;Jun75, Vol. 38 Issue 6, p29 

    Offers nursing tips how to resuscitate a depressed newborn. Principles of resuscitation; Cause of depression in the newborn; Procedures.

  • Referral pattern of neonates with severe respiratory failure for extracorporeal membrane oxygenation. Tiruvoipati, R.; Pandya, H.; Manktelow, B.; Smith, J.; Dodkins, I.; Elbourne, D.; Field, D. // Archives of Disease in Childhood -- Fetal & Neonatal Edition;Mar2008, Vol. 93 Issue 2, pF104 

    Background: Extracorporeal membrane oxygenation (ECMO) remains the mainstay of management in neonates with severe but potentially reversible respiratory failure. In the UK, ECMO is available only as a supraregional service at four centres. Objective: To explore regional variations in ECMO...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics