TITLE

Direct detection effect in small volume hot electron bolometer mixers

AUTHOR(S)
Baselmans, J. J. A.; Baryshev, A.; Reker, S. F.; Hajenius, M.; Gao, J. R.; Klapwijk, T. M.; Vachtomin, Yu.; Maslennikov, S.; Antipov, S.; Voronov, B.; Gol'tsman, G.
PUB. DATE
April 2005
SOURCE
Applied Physics Letters;4/18/2005, Vol. 86 Issue 16, p163503
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We measure the direct detection effect in a small volume (0.15 μm×1 μm×3.5 nm) quasioptical NbN phonon cooled hot electron bolometer mixer at 1.6 THz. We find that the small signal sensitivity of the receiver is underestimated by 35% due to the direct detection effect and that the optimal operating point is shifted to higher bias voltages when using calibration loads of 300 K and 77 K. Using a 200 GHz bandpass filter at 4.2 K the direct detection effect virtually disappears. This has important implications for the calibration procedure of these receivers in real telescope systems.
ACCESSION #
17227463

 

Related Articles

  • Infrared microthermography of microfabricated devices. Furstenberg, Robert; Kendziora, C. A.; Stepnowski, Stanley V.; McGill, R. Andrew // Review of Scientific Instruments;Jun2007, Vol. 78 Issue 6, p064903 

    We report a new experimental apparatus for infrared microthermography applicable to a wide class of samples including semitransparent ones and perforated devices. This setup is particularly well suited for the thermography of microfabricated devices. Traditionally, temperature calibration is...

  • Non-uniform absorption of terahertz radiation on superconducting hot electron bolometer microbridges. Miao, W.; Zhang, W.; Zhong, J. Q.; Shi, S. C.; Delorme, Y.; Lefevre, R.; Feret, A.; Vacelet, T. // Applied Physics Letters;2/3/2014, Vol. 104 Issue 5, p052605-1 

    We interpret the experimental observation of a frequency-dependence of superconducting hot electron bolometer (HEB) mixers by taking into account the non-uniform absorption of the terahertz radiation on the superconducting HEB microbridge. The radiation absorption is assumed to be proportional...

  • Extended function of a high-t[sub c] transition edge bolometer on a micromachined Si membrane. Neff, H.; Laukemper, J. // Applied Physics Letters;9/25/1995, Vol. 67 Issue 13, p1917 

    Uses the superconducting high T[sub c] transition edge bolometer on micromachined silicon membranes as substitutes for infrared quantum detector generation. Effect of temperature on the silicon membranes; Investigation of low T[sub c] Josephson percolation network; Role of thermal resistance...

  • Thin film uncooled microbolometers based on plasma deposited materials1. Kosarev, Andrey; Torres, Alfonso; Moreno, Mario; Ambrosio, Roberto // Canadian Journal of Physics;Jul2014, Vol. 92 Issue 7/8, p570 

    We make a summary of our research and development efforts made about microbolometers (MBs) based on plasma-enhanced chemical vapor deposition (PECVD) materials, like noncrystalline semiconductors that provide high temperature coefficient of resistivity values, in conjunction with SiO x and SiN x...

  • Feasibility of the high Tc superconducting bolometer. Richards, P. L.; Clarke, J.; Leoni, R.; Lerch, Ph.; Verghese, S.; Beasley, M. R.; Geballe, T. H.; Hammond, R. H.; Rosenthal, P.; Spielman, S. R. // Applied Physics Letters;1/16/1989, Vol. 54 Issue 3, p283 

    A design analysis is given for a bolometric infrared detector that uses the resistive transition of a high-temperature superconductor as the temperature sensing element, and liquid nitrogen (LN) as the coolant. It is shown that for highly oriented c-axis films, the measured low-frequency noise...

  • Infrared imaging video bolometer. Peterson, B. J. // Review of Scientific Instruments;Oct2000, Vol. 71 Issue 10 

    A new concept for an infrared imaging bolometer is proposed which provides full video (two-dimensional) imaging of the radiated power from the plasma. This concept preserves all the advantages (compared to conventional metal foil resistive bolometers) of the previously proposed and tested...

  • Design analysis of a high Tc superconducting microbolometer. Hu, Qing; Richards, P. L. // Applied Physics Letters;12/4/1989, Vol. 55 Issue 23, p2444 

    We propose an antenna-coupled microbolometer based on the resistive transition of a high Tc superconducting film as a detector for far infrared and millimeter waves. Such microbolometers can be mechanically stronger, more easily fabricated, and much faster than conventional bolometric infrared...

  • Microbolometer has adjustable responsivity.  // Laser Focus World;Sep2002, Vol. 38 Issue 9, p11 

    Reports that researchers from the University of Minnesota have fabricated microbolometers that have an adjustable thermal conductance. Use of the devices to measure high-temperature processes; Features of the microbolometers; Adjustability of the detector's responsivity; Contact information.

  • Bolometers for infrared and millimeter waves. Richards, P. L. // Journal of Applied Physics;7/1/1994, Vol. 76 Issue 1, p1 

    Presents a study which described bolometric detectors for infrared and millimeter waves. Principles of bolometer operation; Examples of useful bolometers; Thermal properties of bolometer materials.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics