TITLE

Series of Portable Structuroscope-Instruments Based on Measuringthe CoerciveForce

AUTHOR(S)
Bezlyud'ko, G. Ya.; Muzhitskii, V. F.; Remezov, V. B.
PUB. DATE
April 2003
SOURCE
Russian Journal of Nondestructive Testing;Apr2003, Vol. 39 Issue 4, p289
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A series of instruments (structuroscopes) assigned for determining various characteristics of materials and products on the basis of the coercive force is described. Main technical characteristics of three types of the instruments are given. The last and most perfect modification is KRM-Ts-K3 instrument. It is provided with a self-contained power supply and has a wide measurement range. It has an internal memory for 4096 measurements and can be connected to a personal computer. Specially designed program software makes it possible automatically to construct graphs. Examples of graphical representation of the measurement data are demonstrated for two- and three-dimensional reproduction of the results.
ACCESSION #
16981188

 

Related Articles

  • Design for a 10 picometer magnetic actuator. Gauthier-Manuel, B.; Garnier, L. // Review of Scientific Instruments;Jun97, Vol. 68 Issue 6, p2486 

    Describes a magnetic way to produce controlled displacements of surfaces in the nanoscale range without the use of high voltage. Design for a ten picometer magnetic actuator; Principle of the actuator; Transient response.

  • The Effect of Surface Forces on the Thermal Slip of a Simple Gas. Roldughin, V. I.; Zhdanov, V. M. // Colloid Journal;May/Jun2004, Vol. 66 Issue 3, p333 

    The flow of a simple gas along a plane surface under the action of tangential temperature gradient is considered. The velocity of thermal slip is calculated by the variational method with account of the effect of surface forces. It is shown that, in some situations, surface forces can...

  • The THEMIS Magnetic Cleanliness Program. Ludlam, M.; Angelopoulos, V.; Taylor, E.; Snare, R. C.; Means, J. D.; Ge, Y. S.; Narvaez, P.; Auster, H. U.; Le Contel, O.; Larson, D.; Moreau, T. // Space Science Reviews;Sep2008, Vol. 141 Issue 1-4, p171 

    The five identical THEMIS Spacecraft, launched in February 2007, carry two magnetometers on each probe, one DC fluxgate (FGM) and one AC search coil (SCM). Due to the small size of the THEMIS probes, and the short length of the magnetometer booms, magnetic cleanliness was a particularly complex...

  • Honest energy. Israelsohn, Joshua // EDN;4/3/2008, Vol. 53 Issue 7, p28 

    The article discusses issues concerning the energy use that lies outside a strict definition of efficiency that is watts out divided by watts in. It infers that analysis of a load that draws nonsinusoidal current represents the current waveform as a harmonic series with components that are...

  • Design and 3D simulation of a two-cavity wide-gap relativistic klystron amplifier with high power injection. Bai, Xianchen; Yang, Jianhua; Zhang, Jiande // Physics of Plasmas;Aug2012, Vol. 19 Issue 8, p083106 

    By using an electromagnetic particle-in-cell (PIC) code, an S-band two-cavity wide-gap klystron amplifier (WKA) loaded with washers/rods structure is designed and investigated for high power injection application. Influences of the washers/rods structure on the high frequency characteristics and...

  • Mechanics of stretchable electronics and soft machines. Suo, Zhigang // MRS Bulletin;Mar2012, Vol. 37 Issue 3, p218 

    In the emerging field of soft machines, large deformation of soft materials is harnessed to provide functions such as regulating flow in microfluidics, shaping light in adaptive optics, harvesting energy from ocean waves, and stretching electronics to interface with living tissues. Soft...

  • How to specify a connector... Endres, Herbert // Electronics Weekly;3/19/2008, Issue 2327, p24 

    The article suggests on how to choose from a wide range of power connector options available for a wide range of applications. It is important to gather all the relevant information together in order to weigh up the options available and select the most suitable connector for a particular...

  • SHOCK PROTECTION DEVICE FOR ROTATION SENSORS. ALACI, Stelian; CIORNEI, Florina Carmen; AMARANDEI, Dumitru; FILOTE, Constantin; PĂTRAŞ-CICEU, Simion; PRODAN, Dorel // Fiability & Durability / Fiabilitate si Durabilitate;2011, Issue 2, p49 

    Starting form a virtual model of a device designed to investigate friction force effects in colliding mechanical systems, the authors have developed a test-rig. The friction force effects had to be estimated using a rotating sensor. Finally, to protect the sensor from shock effects, a...

  • Internal forces during object manipulation. Gao, Fan; Latash, Mark; Zatsiorsky, Vladimir // Experimental Brain Research;Oct2005, Vol. 165 Issue 1, p69 

    Internal force is a set of contact forces that does not disturb object equilibrium. The elements of the internal force vector cancel each other and, hence, do not contribute to the resultant (manipulation) force acting on the object. The mathematical independence of the internal and manipulation...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library