Suitability of resin-coated photographic paper for skin dose measurement during fluoroscopically-guided X-ray procedures

AUTHOR(S)
Guibelalde E; Gonz''lez L; Va'''' E
PUB. DATE
October 2004
SOURCE
British Journal of Radiology;Oct2004, Vol. 77 Issue 922, p871
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The need for mapping skin doses during fluoroscopically-guided X-ray procedures has been described by a number of institutions and experts. Different large photographic or X-ray films placed on the patient's skin have been found to be useful for recording doses up to 1.0-2.0 Gy - depending on the film - and up to 15 Gy using radiochromic films. Though the upper limit of the film sensitivity is seldom exceeded during interventional procedures, the main disadvantage of the X-ray films is still the excessive sensitivity for long, high dose procedures. Radiochromic films show poor definition for doses below 0.5 Gy and are expensive. The goal of the present paper is to analyse the possibilities of using common resin-coated photographic paper for this purpose. Sensitometric curves obtained with different paper types processed in conventional X-ray film automatic processors demonstrate that some of them can be used with better results than X-ray films at a very low cost. Doses from about 10 mGy to near 3.0 Gy can be measured with good accuracy using a variety of glossy photographic papers.
ACCESSION #
16977589

 

Related Articles

  • Population dose from medical diagnostic exposure in Taiwan. Tung, C. J.; Yang, C. H.; Yeh, C. Y.; Chen, T. R. // Radiation Protection Dosimetry;Jul2011, Vol. 146 Issue 1-3, p248 

    Medical exposure showed a continuous increasing trend. This trend was due to the growth of diagnostic procedures such as computed tomography (CT) and interventional fluoroscopy (IVF). In the present work, results of a recent study on medical exposure in Taiwan are reported. This study analysed...

  • Esophageal Dilation with Polyvinyl (American) Dilators Over a Marked Guidewire: Practice and Safety at One Center Over a 5-Yr Period. Marshall, John B.; Afridi, Shariq A.; King, Paul D.; Barthel, James S.; Butt, James H. // American Journal of Gastroenterology;Aug1996, Vol. 91 Issue 8, p1503 

    Objective: Improvements in dilator technology over the past decade have revolutionized esophageal dilation. There remains, however, a number of controversies relating to several technical aspects of wire-guided dilation, including whether or not fluoroscopy is necessary. We describe our...

  • Image-guided microwave thermoablation of hepatic tumours using novel robotic guidance: an early experience. Mbalisike, Emmanuel; Vogl, Thomas; Zangos, Stefan; Eichler, Katrin; Balakrishnan, Prakash; Paul, Jijo // European Radiology;Feb2015, Vol. 25 Issue 2, p454 

    Objective: To evaluate and compare novel robotic guidance and manual approaches based on procedural accuracy, procedural time, procedural performance, image quality as well as patient dose during image-guided microwave thermoablation. Method: The study was prospectively performed between June...

  • Fluoroscopic Radiation Exposure. Hoffler, C. Edward; Ilyas, Asif M. // Journal of Bone & Joint Surgery, American Volume;5/6/2015, Vol. 97 Issue 9, p721 

    Background: While traditional intraoperative fluoroscopy protection relies on thyroid shields and aprons, recent data suggest that the surgeon's eyes and hands receive more exposure than previously appreciated. Using a distal radial fracture surgery model, we examined (1) radiation exposure to...

  • Are we doing enough to minimize fluoroscopic radiation exposure in children? Cohen, Mervyn // Pediatric Radiology;Oct2007, Vol. 37 Issue 10, p1020 

    The author evaluates methods by which radiologists can control radiation exposure rate during pediatric fluoroscopy. He points out that the review intends to draw attention to the large variation in radiation exposure rates that can result from radiologists making simple, routine adjustments to...

  • CLINICAL X-RAY STAFF CONFERENCES ON THE COLON III. THE IMPORTANCE OF BARIUM ENEMA IN ANORECTAL CASES. Ferguson, Lynn A.; Ferguson, James A.; Van Zwalenburg, Ben R.; Ducey, Edward F. // American Journal of Gastroenterology;May1954, Vol. 21 Issue 5, p405 

    Explores the application of x-ray investigation to assess the importance of barium enema in anorectal cases. Discussion on two related cases; Indication of the pathological study findings; Observations on fluoroscopy during the injection of barium.

  • Computer Navigation Allows for Accurate Reduction of Femoral Fractures. Yoram Weil // Clinical Orthopaedics & Related Research;Jul2007, Vol. 460 Issue 1, p185 

    Femoral nailing for reduction and stabilization of femoral fractures is a common orthopaedic procedure. However, angular and rotational malalignment is not an infrequent result, and extensive use of fluoroscopy is commonly involved. We tested the accuracy of a computerized navigation system to...

  • The use of virtual fluoroscopy in managing acute type II odontoid fracture with anterior single-screw fixation. A safe, effective, elegant and fast form of treatment. Chibbaro, S.; Benvenuti, L.; Carnesecchi, S.; Marsella, M.; Serino, D.; Gagliardi, R. // Acta Neurochirurgica;Jul2005, Vol. 147 Issue 7, p735 

    Background. The management of odontoid fractures represents both a clinical and a technical challenge due to the singular anatomy and biomechanics of the region. At present there is still much controversy as far as any form of management (surgical vs. conservative) is concerned and in any case...

  • Reliability of self-reported diagnostic radiation history in BRCA1/2 mutation carriers. Pijpe, Anouk; Manders, Peggy; Mulder, Renée; Leeuwen, Flora; Rookus, Matti // European Journal of Epidemiology;Feb2010, Vol. 25 Issue 2, p103 

    We assessed reliability of self-reported diagnostic radiation history in BRCA1/2 mutation carriers with and without breast cancer. Within the frame-work of the HEBON study, 401 BRCA1/2 mutation carriers completed a baseline (1999–2004) and a follow-up questionnaire (2006–2007)....

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics