TITLE

Utilization of rapid-infuser devices for massive blood loss

AUTHOR(S)
Stammers, Alfred H.; Murdock, James D.; Klayman, Myra H.; Trowbridge, Cody; Yen, Bianca R.; Franklin, David; Elmore, James
PUB. DATE
March 2005
SOURCE
Perfusion;Mar2005, Vol. 20 Issue 2, p65
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Rapid volume replacement for severe hemorrhage continues to challenge the clinician involved in the care of the patient suffering hemorrhagic shock. We report on the development and utilization of two rapid-infuser systems for volume replacement in critically ill patients presenting in extremis. We have developed rapid-infusion circuits by using commercially available devices available at our institution. The primary pumping mechanism is either a centrifugal pump (Revolution™ – COBE Cardiovascular, Arvada, CO, USA), or the Myocardial Protection System (MPS™ – Quest Medical, Allen, TX, USA), and offers advantages over commercially available devices. Both circuits consist of a cardiotomy reservoir, a cardioplegia delivery set, assorted tubing and connectors, and a heater–cooler system. Between January and October of 2003, 15 procedures were performed which utilized one of these two devices. There were nine ruptured aneurysms, five traumas and one radical nephrectomy. The rapid infusion time averaged 228.5 ± 105.7 min where 10.4 ± 9.4 L of autotransfusion volume was processed, with 3.9 ± 4.2 L of red cell volume reinfused. The allogeneic blood products that were transfused included packed red blood cells and fresh frozen plasma, as well as 5% albumin. There were no intraoperative deaths and the rapid-infuser was considered lifesaving in all instances. Mechanical rapid infusion systems may be lifesaving when severe hypovolemia or hemorrhagic shock is encountered. While both devices are able to meet the requirements of rapid fluid replacement, the MPS offers the most safety features and has become the standard of care at our institution.
ACCESSION #
16838733

 

Related Articles

  • Early techniques of extracorporeal circulation. Kurusz, Mark // Perfusion;May2003, Vol. 18 Issue 3, p191 

    This article focuses on techniques of extracorporeal circulation used prior to 1960 and as reported by the pioneers. A variety of equipment and safety devices were used, and a myriad of set-up and cannulation techniques were described. Sterilization of all blood contacting components, an issue...

  • The heart of the matter.  // Environmental Engineering;Dec2010, Vol. 23 Issue 3/4, p35 

    The article discusses the development of the intelligent Ventricular Assist Device (iVAD) at the University of Leeds-England. The device is being designed as an artificial muscle wrap which assists the failing heart through the application of compressive force around the external surface of the...

  • Anaesthesia for autotransplantation after extracorporeal nephron sparing surgery for bilateral giant renal angiomyolipoma. Rajmohan, Nisha; Neeta, S.; Das, H. K. // Indian Journal of Anaesthesia;Jan/Feb2014, Vol. 58 Issue 1, p66 

    Extracorporeal 'work bench surgery' with subsequent autotransplantation is a challenge from both anaesthetic and surgical point of view when performed bilaterally or in a solitary kidney. A 28-year-old female with bilateral giant angiomyolipoma of kidneys was taken up for renal...

  • Thromboelastography Is a Suboptimal Test for Determination of the Underlying Cause of Bleeding Associated With Cardiopulmonary Bypass and May Not Predict a Hypercoagulable State. Welsh, Kerry J.; Padilla, Angelica; Dasgupta, Amitava; Nguyen, Andy N. D.; Wahed, Amer // American Journal of Clinical Pathology;Oct2014, Vol. 142 Issue 4, p492 

    Objectives: Patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) are at risk of bleeding. The goal of this investigation was to compare thromboelastography (TEG) with standard coagulation tests (prothrombin time [PT], partial thromboplastin time [PTT], fibrinogen, and D-dimer)...

  • Designer arteries. Campbell, Julie; Campbell, Gordon // Australasian Science;Oct2000, Vol. 21 Issue 9, p36 

    Discusses the development of artificial arteries which can be used to replace or bypass diseased arteries. Limitations of synthetic vascular implants; Benefits of artificial arteries.

  • Trouble with Your Ticker? Bag It. Kirschner, Suzanne Kantra; Moyer, Michael // Popular Science;Feb2002, Vol. 260 Issue 2, p11 

    Introduces a mesh-like jacket that protects the heart's muscles against the stretching resulted from stress that leads to heart failure.

  • Levels of inflammatory markers in the blood processed by autotransfusion devices during cardiac surgery associated with cardiopulmonary bypass circuit. Amand, T; Pincemail, J; Blaffart, F; Larbuisson, R; Limet, R; Defraigne, JO // Perfusion;Mar2002, Vol. 17 Issue 2, p117 

    Intraoperative blood salvage devices allowing a reinfusion of red blood cells (RBCs) after processing of shed blood and stagnantblood in the mediastinal cavity are more and more used to reduce homologous blood requirements in cardiac surgery with cardiopulmonary bypass (CPB). As the...

  • Scalp hematoma: An atypical presentation of neurofibromatosis and a cause of hemorrhagic shock. Samra, T. // Journal of Postgraduate Medicine;Jul-Sep2014, Vol. 60 Issue 3, p349 

    The article discusses the case of a 25-year-old men who was hypotensive and anemic and was transferred to the Neurosurgery Operation Theater (OT) for evacuation of a large scalp hematoma. Based on computed tomography (CT) scan, he has a subcutaneous soft tissue density overlying the left...

  • haemorrhagic shock. Peters, Michael // BMA A-Z Family Medical Encyclopedia;2004, p356 

    A definition of the term "haemorrhagic shock" is presented. This term refers to a type of shock characterized by a reduction of blood flow throughout the body tissues. It is caused by severe blood loss.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library