TITLE

Differential pulse voltammetry studies of heavy metal fluoride melts

AUTHOR(S)
Macfarlane, D.R.; Zhou, Zhiping; Newman, P.J.
PUB. DATE
February 2004
SOURCE
Journal of Applied Electrochemistry;Feb2004, Vol. 34 Issue 2, p197
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A study of the electrochemistry of trace metals in heavy metal fluoride melts at 550 °C has been conducted at a stationary electrode with a view to establishing electroanalytical methods for these melts. Reproducible differential pulse voltammetry traces were obtained, the trace metal oxidation peaks behaving as predicted by the theory of Osteryoung et al. The peak current for Fe2+ reduction in a fluoride melt was found to be linear in pulse amplitude up to 70 mV and linear in (pulse duration)-1/2. The peak potential was also found to be a linear function of pulse amplitude. Scan rates around 3 mV s-1 and sampling times around 8 ms were found to produce the optimum analytical response.
ACCESSION #
16781895

 

Related Articles

  • Microelectrode Arrays and Microfabricated Devices in Electrochemical Stripping Analysis. Beni, Valerio; Arrigan, Damien W. M. // Current Analytical Chemistry;Jul2008, Vol. 4 Issue 3, p229 

    In this article a comprehensive overview of the developments in the field of electrochemical stripping analysis with microelectrode arrays and microfabricated devices is presented. Due to the vastness of the topic, this mini-review deals only with the use of regular microelectrode arrays. After...

  • ELECTROCHEMICAL SENSORS FOR HEAVY METAL IONS DETECTION FROM AQUEOUS SOLUTIONS. Tutulea, Mihaela Dana; Cretescu, Igor; Sibiescu, Doina; Stan, Corneliu // Environmental Engineering & Management Journal (EEMJ);Feb2012, Vol. 11 Issue 2, p463 

    Due to the major negative impact of heavy metal ions toward human health and environment,, even at low concentrations, the development of simple, fast and not expensive detection methods of heavy metals is a major challenge for the scientists. Among the different analytical methods for the...

  • Determination Of Some Trace Heavy Metals In Tap Water Of South Saudi Arabia by Anodic Stripping Voltammetry Technique. Alshikh, Asia // Nature & Science;Jan2012, Vol. 10 Issue 1, p124 

    In this work, the direct determination of some trace heavy metals in the tap water were carried out by differential pulse anodic stripping voltammetry (DPASV) technique at Multi Mode Electrode (MME) ,mercury drop capillary for MME working electrode, using a differential pulse mode. The stripping...

  • Electrochemical determination of copper(II) using modified glassy carbon electrodes. Bilici, Esra; Yazicigil, Zafer; Tok, Mutahire; Oztekin, Yasemin // Desalination & Water Treatment;Dec2012, Vol. 50 Issue 1-3, p198 

    Electrochemical modification of glassy carbon (GC) electrode surface via electrochemical oxidation of 1-aminoindan in acetonitrile including 100.0mM of tetrabutylammonium tetrafluoroborate and applicability of electrode modified in this way for electrochemical determination of copper(II)...

  • Effect of halides on the electrochemiluminescence of heavy metals at an aluminum electrode. Yagov, V. V. // Journal of Analytical Chemistry;Jan2007, Vol. 62 Issue 1, p76 

    The effect of halides on cathodic electrochemiluminescence spectra of mercury-like ions at an aluminum electrode is studied. A method of changing the solution in concordance with the potential change is proposed to inhibit pitting corrosion arising in the anodic oxidation of aluminum in...

  • The Heavy Metal Equilibrium in the Soil. Butnariu, Monica // Journal of Ecosystem & Ecography;2012, Vol. 2 Issue 1, p1 

    The author reflects on the equilibrium of heavy metals in the soil. She says that the of equilibrium heavy metals in the soil can remain from several hours to few years or days. She mentions that in inferior oxidative states, the heavy metals develop general combinations with strong ionic...

  • Emission properties of PbO-Bi[sub 2]O[sub 3]-Ga[sub 2]O[sub 3]-GeO[sub 2] glasses doped with Tm[sup 3+] and Ho[sup 3+]. Song, Jay Hyok; Heo, Jong; Park, Se Ho // Journal of Applied Physics;6/15/2003, Vol. 93 Issue 12, p9441 

    Heavy metal oxide glasses containing GeO[SUB2] were investigated as potential hosts for 1.48 μm fiber-optic amplifiers because of their low phonon energy. Addition of ⩾ 10 mol % GeO[SUB2] to 0.57PbO-0.25Bi[SUB2]O[SUB3] - 0.18Ga[SUB2]O[SUB3] (mole fraction) glass provided thermal stability...

  • Electrochemical oxidation of phenol on metaloxide electrodes. Bashtan, S.; Bagrii, V. // Journal of Water Chemistry & Technology;Feb2012, Vol. 34 Issue 1, p24 

    We investigated the process of electrochemical oxidation of phenol on titanium-oxide-manganese and oxide-cobalt anodes. The data on the impact of current density and phenol concentration in the solution on the degree of decomposition and energy costs were presented.

  • Synthesis of cobalt-doped barium cerate-zirconate and its evaluation for hydrogen production and electrochemical characterization. Suresh, Aravind; Basu, Joysurya; Carter, C. Barry; Sammes, Nigel; Wilhite, B. A. // Journal of Materials Science;Jun2010, Vol. 45 Issue 12, p3215 

    Cobalt-doped barium cerate-zirconate was synthesized using an oxalate co-precipitation route. The material was characterized using X-ray diffraction, transmission and scanning transmission electron microscopy coupled with X-ray energy dispersive spectroscopy. Results indicated that homogeneous...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics