Hysteresis and control of ferromagnetic resonances in rings

Giesen, F.; Podbielski, J.; Korn, T.; Steiner, M.; van Staa, A.; Grundler, D.
March 2005
Applied Physics Letters;3/14/2005, Vol. 86 Issue 11, p112510
Academic Journal
The spin dynamics in narrow ferromagnetic rings is studied in the frequency range from 45 MHz to 20 GHz at room temperature. Our broadband spectrometer allows us to monitor the ferromagnetic resonance of characteristic spin configurations as a function of an external field μ0H. We observe hysteresis and irreversible jumps of the resonance frequencies which we attribute to onion-to-vortex and vortex-to-reversed-onion transitions.


Related Articles

  • Quasi magnetic isotropy and microwave performance of FeCoB multilayer laminated by uniaxial anisotropic layers. Shandong Li; Honglei Du; Yongcheng Zhang; Qian Xue; Xiaoyang Gao; Weiquan Shao; Ziyao Zhou; Tianxiang Nan; Sun, Nian X. // Journal of Applied Physics;2014, Vol. 115 Issue 17, p17A310-1 

    A Fe0.7Co0.3-B multilayer was laminated by three Fe0.7Co0.3-B ferromagnetic sublayers prepared by composition gradient sputtering. Three Fe0.7Co0.3-B ferromagnetic sublayers have their individual directions of uniaxial magnetic anisotropy, and the easy magnetic axis of neighboring sublayer...

  • Quasiferromagnetism in semiconductors. Dubroca, T.; Hack, J.; Hummel, R. E.; Angerhofer, A. // Applied Physics Letters;5/1/2006, Vol. 88 Issue 18, p182504 

    Ferromagnetic hysteresis has been observed at room temperature in materials not consisting of elements commonly associated with ferromagnetism, such as Co, Ni, Fe, or Mn-containing alloys. In particular, we report on magnetic hysteresis seen in silicon prepared by two different techniques: ion...

  • Stabilization of the magnetic resonance position by a harmonized field. Ivanchenko, E. A. // Low Temperature Physics;Jul2005, Vol. 31 Issue 7, p577 

    A two-level system in a magnetic field with a periodic temporal modulation that stabilizes the position of the magnetic resonance is investigated in the density matrix formalism. An exact solution is found for the density matrix at resonance. It is shown that at resonance the probability of a...

  • Slick operation. Wilks, Neil // Environmental Engineering;Feb2011, Vol. 24 Issue 1, p29 

    The article focuses on a nuclear magnetic resonance (NMR) spectrometer that can rapidly assess the condition of a patient's metabolism sample and provide accurate information to surgeons in about 20 minutes, installed at St Mary's Hospital in Paddington, England. A definition of metabolism is...

  • On-chip detection of ferromagnetic resonance of a single submicron Permalloy strip. Costache, M. V.; Sladkov, M.; van der Wal, C. H.; van Wees, B. J. // Applied Physics Letters;11/6/2006, Vol. 89 Issue 19, p192506 

    The authors measured ferromagnetic resonance of a single submicron ferromagnetic strip, embedded in an on-chip microwave transmission line device. The method used is based on detection of the oscillating magnetic flux due to the magnetization dynamics, with an inductive pickup loop. The...

  • Ferromagnetic Resonance in Epitaxial Films of Uniaxial Barium Hexaferrites. Zavislyak, I. V.; Kostenko, V. I.; Chamor, T. G.; Chevnyuk, L. V. // Technical Physics;Apr2005, Vol. 50 Issue 4, p520 

    The magnetic parameters of epitaxial barium hexaferrite films are studied. The hysteresis of the field and frequency dependences of ferromagnetic resonance in the films is investigated in the ranges of the multidomain–monodomain and monodomain–multidomain transitions. The effect of...

  • Exchange bias and vertical loop shifts in a Co(32 Ã…)/NiO(10 Ã…)/[Co(4 Ã…)/Pt(6 Ã…)]4 multilayer. Liu, Z. Y. // Applied Physics Letters;11/22/2004, Vol. 85 Issue 21, p4971 

    Investigation has been performed on exchange bias in a Co(32 Ã…)/NiO(10 Ã…)/[Co(4 Ã…)/Pt(6 Ã…)]4 multilayer after cooling at remanence. The easy axes of the Co/Pt multilayer and the 32 Ã… Co layer are different. Both exchange bias and vertical loop shifts have been observed in the...

  • CoCr/Pt multilayers with adjustable perpendicular anisotropy. Papaioannou, E. Th.; Lenz, K.; Charilaou, M.; Fumagalli, P.; Poulopoulos, P.; Angelakeris, M.; Flevaris, N. K.; Wilhelm, F.; Rogalev, A. // Journal of Applied Physics;May2008, Vol. 103 Issue 9, p093905 

    CoCr/Pt multilayers are studied with respect to their structure, magnetic, and magneto-optical properties in an effort to produce novel films suitable for perpendicular magnetic recording. The multilayered structure and the face centered cubic stacking of the films are evidenced by x-ray...

  • Scientific Exhibits (SE).  // European Radiology;Feb2001 Supplement, Vol. 11, p361 

    The article presents abstracts on chest radiology topics like a pictorial review of mediastinal masses, magnetic resonance tomography (MRT) and magnetic resonance angiography (MRA) of hypogenetic lung syndrome, and fissural anatomy demonstrated using multislice computerized tomography (CT).


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics