TITLE

Catheter Separation During Cardiac Catheterization and Coronary Angiography. A Report of Four Incidents and Review of the Literature

AUTHOR(S)
Kyriakides, Zenon S.; Bellenis, Ion P.; Caralis, Dennis G.
PUB. DATE
October 1986
SOURCE
Angiology;Oct1986, Vol. 37 Issue 10, p762
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Four incidents of catheter separation in three patients during left heart catheterization and coronary angiography are presented. In two cases the catheters had been used before. After the second incident, we decided to use angiography catheters once only. All catheter fragments were removed under local anesthesia, and no further complications arose. In all incidents the point of catheter fracture was near the bond between the body of the catheter and its tip. We believe that catheter separation is related to polymer aging. The catheters in the third and fourth incidents were unused, but there was no expiration date on their packages. We recommend that (1) expiration dates be clearly stated on every catheter package, (2) catheter manufacturers issue warnings not to use catheters after expiration date, and (3) unused angiography catheters with no expiration date not be used. We also suggest that consideration be given to using catheters once only.
ACCESSION #
16479458

 

Related Articles

  • Determinants of Left Ventricular Ejection Fraction by Ultrafast Computed Tomography. McMillan, Robert M.; Rees, Michael R. // Angiology;Mar1988 Part 1, Vol. 39 Issue 3, p203 

    Twenty-seven patients had left ventricular ejection fraction (LVEF) measured by catheterization, single-plane angiography, and ultrafast computed tomography (cine CT). Twelve patients (mean age sixty-two years) had LVEF measured by use of the cine CT long-axis view LAV), and 15 patients (mean...

  • Neurovascular MRI with dynamic contrast-enhanced subtraction angiography. Coley, S. C.; Wild, J. M.; Wilkinson, I. D.; Griffiths, P. D. // Neuroradiology;Dec2003, Vol. 45 Issue 12, p843 

    The first generation of digital subtraction MR angiography using thick-slab contrast-enhanced 2D projection techniques has confirmed the potential of MRI to produce noninvasive subsecond angiograms of the craniocervical circulation. As time-resolved techniques become more sophisticated and 3D...

  • Central line pump infusion and large volume mediastinal contrast extravasation in CT. P O'Sullivan; M Brown; B Hartnett; J R Mayo // British Journal of Radiology;Aug2006, Vol. 79 Issue 944, pe75 

    The use of multidetector CT scanners for CT angiography requires rapid injection of radiographic contrast media. Central venous catheters are now widely used for this purpose. Several complications may occur while using central venous access for rapid, large volume contrast injection such as...

  • In vitro comparison of neonatal suction catheters using simulated 'pea soup' meconium. Zareen, Zunera; Hawkes, Colin Patrick; Krickan, Edward R.; Dempsey, Eugene Michael; Ryan, C. Anthony // Archives of Disease in Childhood -- Fetal & Neonatal Edition;May2013, Vol. 98 Issue 3, pF241 

    Background A variety of suction catheters (type, size and design) are recommended for oropharyngeal suctioning of meconium during newborn resuscitation, but it is not known which performs best. In this study we compared different sizes of soft catheters, the Yankauer (YK) and the portable bulb...

  • Non-invasive cardiac output monitoring during catheter interventions in patients with cavopulmonary circulations. Noonan, Patrick Michael Emmet; Viswanathan, Sangeetha; Chambers, Amy; Stumper, Oliver // Cardiology in the Young;Jun2014, Vol. 24 Issue 3, p417 

    Introduction: Functionally univentricular hearts palliated with superior or total cavopulmonary connection result in circulations in series. The absence of a pre-pulmonary pump means that cardiac output is more difficult to adjust and control. Continuous monitoring of cardiac output is crucial...

  • Atrium Medical wins CE mark for ClearWay RX catheter.  // Cardiovascular Device Update;May2007, Vol. 13 Issue 5, p13 

    The article reports that Atrium Medical has received the CE mark for a ClearWay RX small-vessel therapeutic perfusion catheter. The catheter is indicated for localized delivery of therapeutic agents to the coronary and peripheral vasculature. The device is a low-pressure perfusion catheter...

  • Muscular subaortic Stenosis. Borromeo, Lorenzo; Wilson, William S. // Annals of Internal Medicine;Feb71, Vol. 74 Issue 2, p242 

    Describes the findings observed in a patient with muscular subaortic stenosis who developed temporary atrioventricular dissociation during diagnostic cardiac catheterization. Medical profile of the patient; Result of the patient's physical examination; Nature of the obstruction in the left...

  • 662 Association of the ratio of peak E-wave velocity to flow propagation velocity with left ventricular pathology and filling pressures. A Doppler-catheterization study. Popescu, A. C.; Popescu, B. A.; Feinberg, M. S.; DiSegni, E.; Guetta, V.; Rath, S.; Eldar, M.; Schwammenthal, E. // European Journal of Echocardiography;2003, Vol. 4 Issue suppl_1, pS77 

    An abstract of the article "Association of the Ratio of Peak E-Wave Velocity to Flow Propagation Velocity With Left Ventricular Pathology and Filling Pressures: A Doppler-Catheterization Study" by A. C. Popescu and colleagues is presented.

  • Off-Pump Insertion of an Extracorporeal LVAD through a Left Upper- Quadrant Incision. Cohn, William E.; Frazier, O. H. // Texas Heart Institute Journal;2006, Vol. 33 Issue 1, p48 

    Insertion of an extracorporeal left ventricular assist device for temporary ventricular support via median sternotomy can be challenging in patients with a history of cardiac surgery, because these patients often poorly tolerate the lengthy dissection and cardiac manipulation necessary for...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics