Bedside Hemodynamic Monitoring in the Management of Acute Cardiac Patients

Hutchison, S. J.; Rankin, A. C.; Hutton, I.
October 1986
Angiology;Oct1986, Vol. 37 Issue 10, p702
Academic Journal
Hemodynamic monitoring was performed in 100 acutely ill patients admitted to a Coronary Care Unit, 72 of whom had sustained an acute myocardial infarction (AM1). In patients with AM!, the initial pulmonary capillary wedge (PCW) pressure was related to prognosis, with a mortality of 68% in those with elevated pressures. The mean PCW pressure was 25 mmHg in those who died as compared with l7mmHg (p < 0.001) in the survivors. Cardiac catheterization confirmed the clinical impression of high risk in the majority of cases but also identified those in whom the clinical signs were misleading; 9 of those with AM! (12.5%) had high PCW pressures in the absence of clinical or radiological heart failure. The diagnosis of serious hemodynamic complications of AM! (right ventricular infarction, ventricular septal defect, and mitral regurgitation) was established in 14 cases (19%). There were no serious complications related to catheterization, and we conclude that pulmonary artery catheterization is safe and of clinical value in acutely ill cardiac patients.


Related Articles

  • Autonomic Contribution to Endothelin-1 Increase during Laboratory Anger-Recall Stress in Patients with Coronary Artery Disease. Burg, Matthew M.; Soufer, Aaron; Lampert, Rachel; Collins, Dorothea; Soufer, Robert // Molecular Medicine;May/Jun2011, Vol. 17 Issue 5/6, p495 

    In coronary artery disease (CAD), endothelin-1 (ET-1) is released by activated macrophages and thereby contributes to coronary plaque rupture and triggered cardiac events. The multifactorial regulation of ET-1 includes stimulated release by cytokines and autonomic factors. Laboratory stress...

  • The Failing Heart Under Stress: Echocardiography is an Essential Monitoring Tool in the Intensive Care Unit. Poelaert, Jan // Seminars in Cardiothoracic & Vascular Anesthesia;Mar2006, Vol. 10 Issue 1, p111 

    Echocardiography has been evolving to play a pivotal role in hemodynamic management, both intraoperatively and at the bedside. A full assessment of hemodynamics necessitates the use of all of the options available on modern echocardiographs. This introductory review provides insight into three...

  • Hemodynamic monitoring development: helpful technology or expensive luxury? Bendjelid, Karim // Journal of Clinical Monitoring & Computing;Oct2012, Vol. 26 Issue 5, p337 

    The author present his views on recent advances in hemodynamic monitoring to manage critically ill patients. He notes that survival rate did not improve despite increased availability of the monitoring process and monitoring equipment. He also mentions the increasing cost of these hemodynamic...

  • Haemodynamic response to endotracheal intubation in coronary artery disease: Direct versus video laryngoscopy. Kanchi, Muralidhar; Nair, Hema C.; Banaka, Sanjay; Murthy, Keshava; Murugesan, C. // Indian Journal of Anaesthesia;May/Jun2011, Vol. 55 Issue 3, p260 

    Endotracheal intubation involving conventional laryngoscopy elicits a haemodynamic response associated with increased heart and blood pressure. The study was aimed to see if video laryngoscopy and endotracheal intubation has any advantages over conventional laryngoscopy and endotracheal...

  • Refractory Vascular Spasm Associated with Coronary Bypass Grafting. Young Sam Kim; Yong Han Yoon; Jeoung Taek Kim; Ki Shinn, Helen; Seong Ill Woo; Wan Ki Baek // Korean Journal of Thoracic & Cardiovascular Surgery;Oct2014, Vol. 47 Issue 5, p468 

    Diffuse refractory vascular spasms associated with coronary bypass artery grafting (CABG) are rare but devastating. A 42-year-old male patient with a past history of stent insertion was referred for the surgical treatment of a re-current left main coronary artery disease. A hemodynamic...

  • Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Vallée, Fabrice; Fourcade, Olivier; De Soyres, Olivier; Angles, Olivier; Sanchez-Verlaan, Pascale; Pillard, Fabien; Smail, Nadia; Olivier, Michel; Genestal, Michèle; Samii, Kamran // Intensive Care Medicine;Oct2005, Vol. 31 Issue 10, p1388 

    Objective: Esophageal Doppler allows continuous monitoring of stroke volume index (SVI) and corrected flow time (FTc). We hypothesized that variations in stroke output index SOI (SVI/FTc) during volume expansion can predict the hemodynamic response to subsequent fluid loading better than the...

  • Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Reuter, Daniel A.; Felbinger, Thomas W.; Schmidt, Christian; Kilger, Erich; Goedje, Oliver; Lamm, Peter; Goetz, Alwin E. // Intensive Care Medicine;Apr2002, Vol. 28 Issue 4, p392 

    Objective: We hypothesized that measuring stroke volume variation (SVV) during mechanical ventilation by continuous arterial pulse contour analysis allows the accurate prediction and monitoring of changes in cardiac index (CI) in response to volume administration. Design and setting: Prospective...

  • EDITORIAL. Irion, Glenn L. // Journal of Acute Care Physical Therapy (Acute Care Section - APT;Summer2011, Vol. 2 Issue 2, p43 

    The article discusses various reports published within the issue, including exercise adherence issues in hospitalized patients with coronary heart disease (CHD), clinical decision making in the acute care environment, and improving the response time to referrals for physical therapy in the acute...

  • EDWARDS PREVIEWS MINIMALLY INVASIVE HEART MONITOR.  // Biotech Equipment Update;Mar2005, p5 

    The article reports that Edwards Lifesciences Corp., a global leader in hemodynamic monitoring technologies, has previewed its Edwards FloTrac sensor, a new minimally invasive hemodynamic monitoring device, at the Society of Critical Care Medicine's 34th Critical Care Congress. The sensor's...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library