Benchimol, Alberto
January 1977
Angiology;Jan1977, Vol. 28 Issue 1, p58
Academic Journal
A 54-year-old woman underwent replacement of a thrombosed Bj�rk-Shiley aortic valve prosthesis. Post operative electrical defibrillation resulted in isolated T wave alternation which progressed to total QRS-T electrical alternans. This report represents the first description of such a phenomenon.


Related Articles

  • Vagal stimulation to halt supraventricular tachycardia. Sadovsky, Richard // American Family Physician;7/1/1998, Vol. 58 Issue 1, p230 

    Presents a summary of the article `Comparison of Treatment of Supraventricular Tachycardia by Valsalva Maneuver and Carotid Sinus Massage,' by S.H. and others, which was published in the January 1998 edition of the journal `Annals of Emergency Medicine.' Identification of the two methods of...

  • Valve Sparing Aortic Root Repairs�An Anatomical Approach. Matalanis, George // Heart, Lung & Circulation;Sep2004 Supplement 3, Vol. 13, pS13 

    While modern prostheses for aortic valve replacement provide a good substitute for the diseased aortic valve, they are still associated with a small but significant risk of complications. Thus, preservation of the native undiseased aortic leaflets during aortic root replacement is particularly...

  • Mitral Valve Replacement in a Severely Calcified Posterior Annulus: A Novel Technique. El-Amin, Wail O.; Thomson, Duncan S. // Heart, Lung & Circulation;Apr2006, Vol. 15 Issue 2, p146 

    We describe a technique for insertion of a mitral valve prosthesis in the presence of severe posterior annular calcification by plicating the left atrial tissue over the sewing ring. Extensive calcification often creates the technical difficulty of seating the prosthetic valve resulting in peri...

  • Cloth Disruption in a Totally Cloth Covered Aortic Prosthesis: Case Report. Schachner, Arie; Levy, Morris J. // Angiology;Sep1974, Vol. 25 Issue 8, p554 

    A 40 year old male underwent aortic valve replacement with a totally cloth covered (Model 2320) Starr-Edwards prosthesis. Fifteen months later he required re-operation because of a paravalvular leak and a refractory hemolytic anemia. Extensive tear along the cloth covering the inner face of all...

  • External Defibrillation Failure Due to Antimicrobial Incise Drape. Barbara, David W.; Dietz, Niki M.; White, Roger D.; Pochettino, Alberto; Nuttall, Gregory A. // Mayo Clinic Proceedings;Sep2013, Vol. 88 Issue 9, p1032 

    Antimicrobial incise drapes adhere to a patient's skin during surgery in an attempt to reduce surgical infections. We describe a patient undergoing repeated aortic valve replacement who experienced sudden ventricular fibrillation before median sternotomy. External defibrillation was unsuccessful...

  • Aortico-Left Ventricular Tunnel: A Case Report. Withurawanit, Wichaya; Samankatiwat, Piya; Wongwandee, Ratthapon; Bhuddaraksa, Vuthapong // Thai Journal of Surgery;Jan-Mar2008, Vol. 29 Issue 1, p28 

    A 12 year-old girl who underwent PDA ligation since she was 1 year old came to the hospital with a problem of easy tiredness. After surgery, there was no residual PDA but mild aortic insufficiency. One year previously, she complained of easily getting tired and experienced occasional abnormal...

  • Doppler Echocardiographic Assessment of Normally Functioning Starr--Edwards, Carbomedics and Carpentier--Edwards Valves in Aortic Position. Chakraborty, Barendra; Quek, Susan; Pin, Ding Zee; Siong, Chee Tek; Kheng, Tan Lay // Angiology;May1996, Vol. 47 Issue 5, p481 

    Doppler echocardiography was performed in 168 normally functioning aortic prostheses to determine acceptable pressure gradients across the commonly used valves and to establish the relationship between valve size and gradients. There were 82 Carbomedics (C), 63 Starr-Edwards (SE), and 23...

  • Is there a role of statins in the prevention of aortic biological prostheses degeneration. Antonini-Carterin, Francesco; Zuppiroli, Alfredo; Baldessin, Ferdinando; Popescu, Bogdan A.; Nicolosi, Gian Luigi // Cardiovascular Ultrasound;2006, Vol. 4, p26 

    It has been recently observed that statins might slow the progression of aortic stenosis or sclerosis. Preliminary reports suggested a similar positive effect in reducing the degeneration of aortic valve bioprostheses even though this hypothesis should be further proven and supported by new...

  • Pericarbon Pericardial Valve Prosthesis: Midterm Results of the Aortic Valve Replacement. Borowiec, Jan W.; Dubiel, Thomas W.; Hansson, Hans-Erik; Landelius, Johan; Nystr�m, Sven-Olov // Angiology;Jan1998, Vol. 49 Issue 1, p1 

    This clinical study was undertaken to verify the encouraging results of experimental studies regarding a new pericardial bioprosthesis. From May 1989 to November 1993, 204 patients underwent an aortic valve replacement with the Pericarbon� (Sorin Biomedica Cardio S.p.A., Saluggia, Italy)...