TITLE

CLINICAL EXPERIENCE WITH THE CUTIS VASCULAR GRAFT

AUTHOR(S)
Wagner, Marvin; Benjamin, H. B.; Zeit, Walter
PUB. DATE
February 1961
SOURCE
Angiology;Feb1961, Vol. 12 Issue 2, p57
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A review of five cases has been made scrutinizing each case carefully relative to the efficiency and practically of the autoplastic cutis vascular graft as a prothesis. All of the cases, except for two, have remained patent and are functioning. The longest functioning graft is over 36 months old. Of the two grafts that occluded, one was due to trauma, and the other due to host vessel thrombosis.
ACCESSION #
16395717

 

Related Articles

  • FDA clears Ethicon's Enseal G2 articulating tissue sealer. PEDERSEN, AMANDA // Medical Device Daily;2/ 5/2013, Vol. 17 Issue 24, p1 

    The article offers brief information on the Enseal G2 articulating tissue sealer from Ethicon Endo-Surgery which has been cleared by the U.S. Food and Drug Administration (FDA).

  • Feasibility Trial of Carotid Stenting With and Without an Embolus Protection Device. Ouriel, Kenneth; Wholey, Mark H.; Fayad, Pierre; Katzen, Barry T.; Whitlow, Patrick; Frentzko, Michael; Kunt, Richard E.; Wechsler, Lawrence; Hopkins, Nelson; Satler, Lowell; Mishkel, Greg; Yadav, Jay S. // Journal of Endovascular Therapy (Allen Press Publishing Services;Oct2005, Vol. 12 Issue 5, p525 

    Purpose: To evaluate the feasibility of stenting and cerebral protection in patients with carotid bifurcation disease. Methods: Carotid stenting with self-expanding nitinol stents was evaluated in 261 patients (157 men; mean age 70.9±9.7 years, range 41-90) treated at 33 clinical sites. Among...

  • Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents. Grines, Cindy L.; Bonow, Robert O.; Casey Jr, Donald E.; Gardner, Timothy J.; Lockhart, Peter B.; Moliterno, David J.; O'Gara, Patrick; Whitlow, Patrick // Journal of the American Dental Association (JADA);May2007, Vol. 138 Issue 5, p652 

    The article warns against premature discontinuation of dual antiplatelet therapy after coronary stenting. According to the authors, discontinuation of antiplatelet therapy greatly increases the risk of stent thrombosis, myocardial infarction and death. The authors stress the importance of 12...

  • Fluid-Dynamic Optimal Design of Helical Vascular Graft for Stenotic Disturbed Flow. Ha, Hojin; Hwang, Dongha; Choi, Woo-Rak; Baek, Jehyun; Lee, Sang Joon // PLoS ONE;Oct2014, Vol. 9 Issue 10, p1 

    Although a helical configuration of a prosthetic vascular graft appears to be clinically beneficial in suppressing thrombosis and intimal hyperplasia, an optimization of a helical design has yet to be achieved because of the lack of a detailed understanding on hemodynamic features in helical...

  • PRODUCT MARKETPLACE.  // ENT: Ear, Nose & Throat Journal;Nov2004, Vol. 83 Issue 11, p787 

    Evaluates various surgical products. Blom-Singer 16 Fr voice prosthesis device from InHealth Technologies; Femot Stabilizer retractor stabilizer from Samanghen Corp.; PenAdapt electrosurgical pencil adapter from Buffalo Filter.

  • Critical evaluation of a novel DualMesh repair for large hiatal hernias. Hazebroek, E. J.; Koak, Y.; Berry, H.; Leibman, S.; Smith, G. S. // Surgical Endoscopy;Jan2009, Vol. 23 Issue 1, p193 

    The use of mesh for laparoscopic repair of large hiatal hernias may reduce recurrence rates in comparison to primary suture repair. However, there is a potential risk of mesh-related oesophageal complications due to prosthesis erosion. The aim of this study was to critically evaluate a novel...

  • EFFECT OF BISPHOSPHONATES ON PERIPROSTHETIC BONE MINERAL DENSITY AFTER TOTAL JOINT ARTHROPLASTY. Bhandari, Mohit; Bajammal, Sohail; Guyatt, Gordon H.; Griffith, Lauren; Busse, Jason W.; Schünemann, Holger; Einhorn, Thomas A. // Journal of Bone & Joint Surgery, American Volume;Feb2005, Vol. 87-A Issue 2, p293 

    Background: Periprosthetic bone loss following total joint arthroplasty may threaten the survival of the implant. Bisphosphonates are effective in reducing bone loss in conditions associated with accelerated bone turnover. To determine the current understanding of the effect of bisphosphonates...

  • Strength and Mode of Failure of Single Implant All-Ceramic Abutment Restorations Under Static Load. Tripodakis, Aris Petros D.; Strub, Jorg Rudolf; Kappert, Heinz F.; Witkowski, Siegbert // International Journal of Prosthodontics;May/Jun1995, Vol. 8 Issue 3, p265 

    The strength and made of failure of three different designs of custom-made all-ceramic implant abutments fabricated by milling of In-Ceram sintered ceramic blocks were compared with the conventional CeraOne system under static load. Four test groups were formed with different locations of...

  • DAPT duration does not predict risk for fatal events in patients treated with Genous Stent…. Pedersen, Amanda // Medical Device Daily;6/26/2012, Vol. 16 Issue 121, Special section p1 

    The article discusses the result of a study that investigated the safety of Genous Stent in patients who discontinued dual anti platelet therapy (DAPT) within 15 days of placement after coronary angioplasty. Results revealed that DAPT duration does not appear to predict risk of fatal events such...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library