TITLE

ULTRAFILTRATION WITH THE MACNEILL-COLLINS BLOOD DIALYZER

AUTHOR(S)
McLean, Charles E.; Clason, W. Page C.
PUB. DATE
November 1961
SOURCE
Angiology;Nov1961, Vol. 12 Issue 11, p547
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Examines the use of MacNeill-Collins blood dialyzer during ultrafiltration by researchers from Hartford, Connecticut. Efforts of the researchers to establish an artificial kidney program; Exploration on the potential use of ultrafiltration as a method for the removal of edema fluid; Safety and efficacy of MacNeill-Collins blood dialyzer.
ACCESSION #
16377923

 

Related Articles

  • Do dialysate conductivity measurements provide conductivity clearance or ionic dialysance? Petitclerc, T. // Kidney International;Nov2006, Vol. 70 Issue 10, p1682 

    Dialysate conductivity measurements allow on-line estimation of urea clearance during hemodialysis session. Conductivity measurements provide a value of ‘conductivity clearance’ for some authors, but a value of ‘ionic dialysance’ for others. This paper aims at...

  • Ultrafiltration: A mechanism for removal of intermediate molecular weight substances in coil dialyzers. Nolph, Karl D.; Nothum, Richard J.; Maher, John F. // Kidney International;Jul1974, Vol. 6 Issue 1, p55 

    The present studies were undertaken to 1) evaluate independently the effects of intracoil hydrostatic pressure and ultrafiltration rate on dialysance in coils, 2) determine the relationship of intracoil hydrostatic pressure to dialysance in newer Ultra-Flo II coils and 3) compare the dialysance...

  • A new scintigraphic method to characterize ultrafiltration in hollow fiber dialyzers. Ronco, Claudio; Brendolan, Alessandra; Feriani, Mariano; Milan, Massimo; Conz, Piero; Lupi, Andrea; Berto, Paolo; Bettini, MariaCostanza; La Greca, Giuseppe // Kidney International;May1992, Vol. 41 Issue 5, p1383 

    Ultrafiltration and pressure profiles in hollow fiber dialyzers with different hydraulic permeabilities have been investigated with a new scintigraphic method. Radiolabelled albumin macroaggregates, used as a nondiffusible marker molecule, were added to the blood in an in vitro circuit and...

  • hemodialyzer.  // Taber's Cyclopedic Medical Dictionary (2009);2009, Issue 21, p1045 

    An encyclopedia entry for "hemodialyzer" is presented.

  • Hemodialyzer: From macro-design to membrane nanostructure; the case of the FX-class of hemodialyzers. Ronco, Claudio; Bowry, Sudhir Kumar; Brendolan, Alessandra; Crepaldi, Carlo; Soffiati, Giuliano; Fortunato, Antonio; Bordoni, Valeria; Granziero, Alessandro; Torsello, Giuseppe; La Greca, Giuseppe // Kidney International Supplement;May2002, Issue 80, p126 

    Hemodialyzer: From macro-design to membrane nanostructure; the case of the FX-class of hemodialyzers. Very few innovations have characterized the different components of the hemodialyzers in the past 20 years. Most improvements have concerned membrane biocompatibility. In this article, we focus...

  • The oxalate level in ultrafiltrate fluid collected from a dialyzer is useful for estimating the plasma oxalate level in hemodialysis patients. Ogi, Makoto; Abe, Ryoetsu; Nishitani, Tomohito; Wakabayashi, Masanori; Wakabayashi, Tsunemichi // Clinical & Experimental Nephrology;Jun2006, Vol. 10 Issue 2, p118 

    Background. Patients on chronic hemodialysis are likely to develop secondary hyperoxalemia. It is, however, difficult to measure plasma oxalate levels. To measure plasma oxalate levels, rapid plasma separation, deproteinization, and acidification are essential in preventing the formation of...

  • Measurement of dialyzer clearance, dialysis time, and body size: Death risk relationships among patients. Lowrie, Edmund G.; Li, Zhensheng; Ofsthun, Norma; Lazarus, J. Michael // Kidney International;Nov2004, Vol. 66 Issue 5, p2077 

    Measurement of dialyzer clearance, dialysis time, and body size: Death risk relationships among patients.Background.Urea pharmacokinetic equation systems have contributed to better understanding of treatment dose among hemodialysis patients. The methods are indirect, however, and require the...

  • Performance of polysulfone membrane dialyzers and dialysate flow pattern. Nakashima, Ayumu; Ogata, Satoshi; Doi, Shigehiro; Yamahira, Michihiro; Naraki, Satoe; Takasugi, Norihisa; Ohmoto, Toshifumi; Ito, Takafumi; Masaki, Takao; Yorioka, Noriaki // Clinical & Experimental Nephrology;Sep2006, Vol. 10 Issue 3, p210 

    It is important to observe the flow pattern of dialysate when evaluating dialyzer function and developing the most appropriate design. We investigated dialysate flow through two polysulfone membrane dialyzers (TS-UL [Toray Medical] and APS-S [Asahi Medical]) by computed tomography (CT), with...

  • Multiple use of dialyzers: Safety and efficacy. Kant, Kotagal S.; Pollak, Victor E.; Cathey, Margaret; Goetz, Dan; Berlin, Rebecca; Eydel, David F.; Tessel, Judy; Hall, Roberta // Kidney International;May1981, Vol. 19 Issue 5, p728 

    The practice of multiple use of dialyzers was examined over a 15-month period on all 104 patients in a chronic maintenance hemodialysis facility. A computerized medical information system permitted analysis of the incidence of events in over 10.000 successive hemodialyses. It also allowed...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics