TITLE

A new label-free amperometric immunosenor for rubella vaccine

AUTHOR(S)
Lingyan Zhang; Ruo Yuan; Xiaoqing Huang; Yaqin Chai; Dianping Tang; Shurui Cao
PUB. DATE
March 2005
SOURCE
Analytical & Bioanalytical Chemistry;Mar2005, Vol. 381 Issue 5, p1036
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A novel label-free amperometric immunosensor for the detection of rubella vaccine was developed by immobilizing anti-rubella serum on bilayer nano-Au/polymerizedo-phenylenediamine film with electrodeposited Prussian Blue (PB) as an electrode transfer mediator on the platinum electrode. The redox reactions of PB as a probe on the platinum surface were blocked due to the binding of the antibody to the antigen, which was investigated by cyclic voltammetry. Therefore, the interaction of the antibody with various concentrations of antigen could be detected by measurements of amperometric response in PBS, and the amperometric response on the surface of the modified electrode was inversely proportional to the concentration of rubella vaccine in the sample. The immunosensor showed a specific response to rubella vaccine in the range 8.1×10-8-8.0×10-6 lgCCID50/ml (cell culture infectious dose) and a detection limit of 4.010-8 lgCCID50/ml at a signal-to-noise ratio of 3. To summarize, the present work provides a low-cost, fast response time, highly sensitive and easy-to-prepare method for the determination of antigen in biological products.
ACCESSION #
16371462

 

Related Articles

  • THE INFLUENCE OF AUXILIARY ELECTRODE POLARIZATION ON TRANSIENT PROCESSES IN AMPEROMETRIC GAS SENSORS. Linyucheva, O. V.; Buket, O. I.; Vashchenko, O. M.; Tatarchenko, G. O. // Naukovi visti NTUU - KPI;2010, Vol. 2010 Issue 3, p94 

    This study proves that the mode of transient performance in amperometric sensor can clearly indicate the excessive polarization of auxiliary electrode as a root cause of unstable signal or long transition period. These findings allow determining a dramatic decrease in the contact area of...

  • THE INFLUENCE OF DETERMINATE COMPONENT ADSORPTION ON THE TIME OF TRANSITION PROCESSES IN THE AMPEROMETRIC GAS SENSORS. Linyucheva, O. V.; Buket, O. I.; Kushmyiruk, A. I. // Naukovi visti NTUU - KPI;2009, Vol. 2009 Issue 3, p131 

    The chemical sensors are the important elements of present-day resource-saving technologies and complex arrangements of the environment presservation. Among them the most useful are the amperometric gas sensors. They are inexpensive and have current signal registration as well as resistance...

  • Carbon nanotube array-based biosensor. Sotiropoulou, Sofia; Chaniotakis, Nikolas A. // Analytical & Bioanalytical Chemistry;Jan2003, Vol. 375 Issue 1, p103 

    Aligned multi-wall carbon nanotubes (MWNT) grown on platinum substrate are used for the development of an amperometric biosensor. The opening and functionalization by oxidation of the nanotube array allows for the efficient immobilization of the model enzyme, glucose oxidase. The carboxylated...

  • An Effective Amperometric Biosensor Based on Gold Nanoelectrode Arrays. Yanyan Liu; Yingchun Zhu; Yi Zeng; Fangfang Xu // Nanoscale Research Letters;Mar2009, Vol. 4 Issue 3, p210 

    A sensitive amperometric biosensor based on gold nanoelectrode array (NEA) was investigated. The gold nanoelectrode array was fabricated by template-assisted electrodeposition on general electrodes, which shows an ordered well-defined 3D structure of nanowires. The sensitivity of the gold NEA to...

  • Development of a gold-nanostructured surface for amperometric genosensors. Zanardi, Chiara; Baldoli, Clara; Licandro, Emanuela; Terzi, Fabio; Seeber, Renato // Journal of Nanoparticle Research;Oct2012, Vol. 14 Issue 10, p1 

    A gold-nanostructured surface has been obtained by stable deposition of chemically synthesized gold nanoparticles (2.1-5.5 nm size range) on a gold substrate through a dithiol linker. The method proposed for the obtainment of the nanostructure is suitable for the further stable anchoring of a...

  • Platform for a Hydrocarbon Exhaust Gas Sensor Utilizing a Pumping Cell and a Conductometric Sensor. Biskupski, Diana; Geupel, Andrea; Wiesner, Kerstin; Fleischer, Maximilian; Moos, Ralf // Sensors (14248220);2009, Vol. 9 Issue 9, p7498 

    Very often, high-temperature operated gas sensors are cross-sensitive to oxygen and/or they cannot be operated in oxygen-deficient (rich) atmospheres. For instance, some metal oxides like Ga2O3 or doped SrTiO3 are excellent materials for conductometric hydrocarbon detection in the rough...

  • Solid State Gas Sensor Research in Germany - a Status Report. Moos, Ralf; Sahner, Kathy; Fleischer, Maximilian; Guth, Ulrich; Barsan, Nicolae; Weimar, Udo // Sensors (14248220);2009, Vol. 9 Issue 6, p4323 

    This status report overviews activities of the German gas sensor research community. It highlights recent progress in the field of potentiometric, amperometric, conductometric, impedimetric, and field effect-based gas sensors. It is shown that besides step-by-step improvements of conventional...

  • A Novel DNA Electrochemical Sensor Based on Grafting of L-Aspartic Acid and Cu2+ Ions on the Terminal of Molecule Beacons. Xia Wang; Xuan Zhang; Cai Gao; Xiaolei Liao; Le Hang; Shulian Jiang; Feng Gao; Lizhang Huang; Qingxiang Wang // International Journal of Electrochemical Science;Jun2013, Vol. 8 Issue 6, p7529 

    A novel electrochemical DNA biosensor based on in-situ labeling of L-Aspartic acid-copper ion (Asp-Cu2+) complex on the terminal of molecule beacons (MBs) was constructed. The MB with bifunctional groups of 3'-SH and 5'-COOH was first anchored on a gold electrode surface through Au-S assembly...

  • Effect of Diffusion Limitations on Multianalyte Determination from Biased Biosensor Response. Baronas, Romas; Kulys, Juozas; Lančinskas, Algirdas; Žilinskas, Antanas // Sensors (14248220);Mar2014, Vol. 14 Issue 3, p4634 

    The optimization-based quantitative determination of multianalyte concentrations from biased biosensor responses is investigated under internal and external diffusion-limited conditions. A computational model of a biocatalytic amperometric biosensor utilizing a mono-enzyme-catalyzed...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics