TITLE

What is the Optimum A-V Interval in D.D.D. Pacing?

AUTHOR(S)
Rao, Gopal; Winzelberg, Gary; Flaherty, Patrick
PUB. DATE
April 1985
SOURCE
Angiology;Apr1985, Vol. 36 Issue 4, p253
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
One of the programmable parameters in recent pacemakers is atrio-ventricular interval. To find out the optimum A-V interval studies were done in 14 patients. Multigated radionuclide scans were used to measure the left ventricular function, at a resting heart rate of 70/minute. Seven patients had poor left ventricles (ejection fraction <50%). Left ventricular ejection fraction, relative cardiac output and end diastolic counts were highest at 250 M. Sec. interval compared to <50. Ejection rates and end systolic counts were not related to A-V interval. Relative cardiac output was 27% higher in poor ventricles at 250 delay than 150. This observation was not significant in normal hearts. Optimum P-R interval is 250 M. Sec. for maximum left ventricular function.
ACCESSION #
16365197

 

Related Articles

  • The effect of ventricular pacing on measurements of left ventricular function: A comparison between echocardiographic methods and with radionuclide ventriculography. Thackray, Simon D.R.; Wright, Graham A.; Witte, Klaus K.A.; Nikitin, Nikolay P.; Tweddel, Ann C.; Clark, Andrew L.; Cleland, John G.F. // European Journal of Echocardiography;Aug2006, Vol. 7 Issue 4, p284 

    Abstract: Aims: Different methods exist for measuring left ventricular function echocardiographically; each may be error prone due to the abnormal pattern of ventricular activation during pacing. Methods and results: Echocardiography was undertaken on 307 patients with permanent pacemakers; a...

  • Recent Patents in Cardiac Resynchronization Therapy. Hamid, Matthew; Hamid, Ginks; Hamid, Shoaib; Rinaldi, Aldo C. // Recent Patents on Biomedical Engineering;Jun2008, Vol. 1 Issue 2, p136 

    Abstract: Cardiac Resynchronization Therapy (CRT) is a medical procedure which has revolutionized treatment for patients with heart failure. The procedure was first described in 1994. Its benefit relies on the fact that many patients with heart failure have uncoordinated contraction of the left...

  • How does an LVAD work? Zipes, Douglas // Medical Update;2004, Vol. 29 Issue 11, p3 

    Presents information on the functions of a left ventricular assist device. Functions of the different tubes attached to the pump; Location of the pump inside the body; Advantages of the use of the pump by patients with heart failure.

  • Independent and incremental prognostic value of left ventricular ejection fraction determined by stress gated rubidium 82 PET imaging in patients with known or suspected coronary artery disease Lertsburapa, Kirkeith; Ahlberg, Alan W.; Bateman, Timothy M.; Katten, Deborah; Volker, Lyndy; Cullom, S. James; Heller, Gary V. // Journal of Nuclear Cardiology;Nov2008, Vol. 15 Issue 6, p745 

    Background: Whether left ventricular ejection fraction (EF) obtained by gated rubidium 82 positron emission tomography (PET) myocardial imaging can identify patients at risk for future cardiac events is unclear. Methods and Results: Consecutive patients with known or suspected coronary artery...

  • PERMANENT STANDBY TRANSVENOUS PACEMAKING. Smyth, Nicholas P. D.; Bacos, James M. // Angiology;Dec1969, Vol. 20 Issue 11, p676 

    The transvenous system of permanent pacemaking is both simple and safe and is recommended, especially for older patients. The standby (demand) pacemaker functions in all types of symptomatic bradycardia, virtually eliminating the danger of competitive pacing, and is, therefore, recommended in...

  • Implanted Pacemaker.  // Time;10/27/1961, Vol. 78 Issue 17, p83 

    The article reports on the implantation of a pacemaker to patients who can talk about their tickers without being cute. It states that Surgeon William M. Chardack revealed how he and his colleagues at the Veterans Administration Hospital in Buffalo, New York have miniaturized and refined the...

  • Inadvertent transarterial insertion of atrial and ventricular defibrillator leads. Syeda Rumman // Journal of Interventional Cardiac Electrophysiology;Jan2009, Vol. 24 Issue 1, p63 

    Abstract  Inadvertent placement of pacemaker and implantable cardioverter-defibrillator (ICD) leads in the left ventricle (LV) is a rare but well-recognized complication of device implantation [1]. We report a case of inadvertent transarterial implantation of dual-chamber ICD leads; the...

  • New Tools and Techniques. Cohn, William E. // Texas Heart Institute Journal;2010, Vol. 37 Issue 5, p559 

    The article introduces a new method of implanting a left ventricular assist device (LVAD) that uses a vacuum stabilizer to decrease the risks that accompany the implantation of similar off-pump devices on patients with heart failure. It shows how the new technique can be an effective way of...

  • Comparative Study of Left Ventricular Function in Patients with Unstable Angina, Non-Q Wave Myocardial Infarction and Stable Angina Pectoris: Assessment with Atrial Pacing and Digital Ventriculography. Hussain, K. M. A.; Gould, L.; Pomerantsev, E. V.; Angirekula, M.; Bharathan, T. // Angiology;Oct1995, Vol. 46 Issue 10, p867 

    To compare left ventricular global and segmental function at rest and during right atrial pacing in patients with unstable angina, non-Q wave myocardial infarction, and stable angina (class III angina), low-dose digital subtraction ventriculography was performed at rest and after abrupt...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library