Sarma, Radha; Prickett, Charles; Johnson, John L.
September 1976
Angiology;Sep1976, Vol. 27 Issue 9, p502
Academic Journal
The accuracy and advantages of determining percentage of hemoglobin oxygen saturation of whole blood by advanced instruments of oximetry, gas chromatography. and the computation of oxygen saturation from pO2 and pH data are compared with the Van Slyke-Neill manometric method. It was found that oximetry is extremely fast, less expensive, and more accurate than in the past, the apparatus requires little training to operate and has diminutive service maintenance. The gas chromatograph proved to be highly accurate and could serve as a standard calibration check method in place of the more time-consuming Van Slyke-Neill apparatus for oximetry and pO2 and pH electrode instrumentation. Computation of O2 saturation from pO2 and pH data also proved to be accurate, confirming that this method is more useful during cardiac surgery because it can provide additional acid-base information. In the low oxygen saturation range (<60%). all three methods proved to be of similar sensitivity.


Related Articles

  • hemoglobin.  // Taber's Cyclopedic Medical Dictionary (2009);2009, Issue 21, p1046 

    An encyclopedia entry for "hemoglobin" is presented. The terms refers to a pigment of red blood cells that contains iron. Hemoglobin carries oxygen to the tissues from the lungs. Types of hemoglobin include hemoglobin A, Bart's hemoglobin, hemoglobin C, fetal hemoglobin, hemoglobin Lepore and...

  • Characterization of a new hemoglobin variant: Hb Badalona (β31[B13]Leu→Val). Junca, J.; Villegas, A.; Ropero, P.; González, F.; Motos, A.; Valverde, F. // Annals of Hematology;Apr2002, Vol. 81 Issue 4, p179 

    Hemoglobin (Hb) Badalona was identified in a 35-year-old Spanish female and two other family members. All affected subjects presented erythrocytosis and increased oxygen affinity (P50: 21 mmHg). Hemoglobinopathy was not detected with electrophoretic methods. It was, however, separated and...

  • Automatic Retinal Oximetry. Halldorsson, G. H.; Karlsson, R. A.; Hardarson, S. H.; Mura, M. Dalla; Eysteinsson, T.; Beach, J. M.; Stefansson, E.; Benediktsson, J. A. // AIP Conference Proceedings;10/24/2007, Vol. 949 Issue 1, p200 

    This paper presents a method for automating the evaluation of hemoglobin oxygen saturation in the retina. This method should prove useful for monitoring ischemic retinal diseases and the effect of treatment. In order to obtain saturation values automatically, spectral images must be registered...

  • Factors affecting hemoglobin measurement. Berkow, Lauren // Journal of Clinical Monitoring & Computing;Oct2013, Vol. 27 Issue 5, p499 

    A review of the literature shows that current 'standard' laboratory measurements for hemoglobin are subject to numerous factors that affect both accuracy and reliability. In addition, total hemoglobin concentration measurements are subject to numerous factors that affect the 'true' hemoglobin...

  • Robust design of finger probe in non-invasive total haemoglobin monitor. Yoon, G.; Kim, S.-J.; Jeon, K. J. // Medical & Biological Engineering & Computing;Jan2005, Vol. 43 Issue 1, p121 

    The development of a non-invasive monitor of total haemoglobin has been reported previously. The paper presents the design and testing of a finger probe used in that optical haemoglobin monitor. When a finger is inserted into the probe, light is radiated onto the nail, and a silicon detector...

  • An instrumentation assembly for studying operational behavior of thermal gradient programmed gas chromatography. Rubey, Wayne A. // Review of Scientific Instruments;Sep94, Vol. 65 Issue 9, p2802 

    Extensive laboratory experiments and measurements are required for the operational evaluation and optimization of thermal gradient programmed gas chromatography (TGPGC). To accommodate these numerous laboratory investigations, an instrumentation assembly has been designed and constructed which...

  • The Jan�k-Type Gas Chromatographs of the 1950s. Ettre, Leslie S. // LC-GC North America;Sep2002, Vol. 20 Issue 9, p866 

    Examines the development and applications of the Janak-type gas chromatographs of the 1950s. Low-temperature fractional distillation; Liquid column and paper chromatographic analysis of mono- and diphenols; Use of activated charcoal and silica gel as the column packings for separating inorganic...

  • On the Interpretation of GC � GC Data. Harynuk, James; Gorecki, Tadeusz; Campbell, Colin // LC-GC North America;Sep2002, Vol. 20 Issue 9, p876 

    Describes the basic operation of comprehensive two-dimensional gas chromatography systems as well as how data is manipulated as they are transformed from raw signals to more familiar contour plots. Separation mechanisms used in the two dimensions; Two columns with different stationary phases...

  • The Beginnings of Gas Chromatography and Early Symposia Held in the United States.  // LC-GC North America;Sep2003, Vol. 21 Issue 9, p900 

    Discusses the beginnings of gas chromatography (GC) in the United States and symposia that played roles in the dissemination of GC in the U.S. Differences in the evolution of the GC technique in the U.S. and in Great Britain; Availability of commercial gas chromatographs and introductory...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics