TITLE

Study of the lipophilicity of selenium species

AUTHOR(S)
Tsopelas, Fotios N.; Ochsenkühn-Petropoulou, Maria Th.; Tsantili-Kakoulidou, Anna; Ochsenkühn, Klaus-Michael
PUB. DATE
January 2005
SOURCE
Analytical & Bioanalytical Chemistry;Jan2005, Vol. 381 Issue 2, p420
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In this work the lipophilicity of different selenium species occurring in environmental matrices and food, Se(IV), Se(VI), selenomethionine (Se-Met), selenocystamine (Se-CM), selenocystine (Se-Cyst), and dimethyl diselenide (CH3)2Se2, was investigated in the octanol-water system, using the shaking flask method and detection with inductively coupled plasma-atomic emission spectrometry (ICP-AES), in order to assess their environmental fate and tendency to bioaccumulate. Polarography was also used for the electrochemically active Se species, Se(IV), Se-Cyst, Se-CM and (CH3)2Se2, and the results were compared with those measured by ICP-AES. Furthermore, the influence of pH was studied by determining the logarithm of the distribution coefficient, logD, at three pH values, 5, 7, and 9, as was the impact of the marine environment on the lipophilicity profile of the six investigated Se species. The results were compared with those estimated approximately by use of PrologD software, based on the Ghose-Crippen logP(P: partition coefficient) calculation system, the only system which incorporates values-even though approximate-for the atom type of Se. Finally, from our experimental data an indicative value of the Se-Se fragment for logPprediction, for use in drug design, was estimated.
ACCESSION #
16004472

 

Related Articles

  • Computerization of a PARC174A polarographic analyzer. Liao, Shu-Ling; Olson, Carter L. // Review of Scientific Instruments;Jul1993, Vol. 64 Issue 7, p1809 

    A PARCI74A polarographic analyzer has been transformed into a comprehensive microcomputer controlled electroanalytical system by interfacing it with an iBM PC equipped with a Tecmar LabMaster data acquisition subsystem. Techniques implemented include square wave voltammetry, chronoamperometry,...

  • Differential pulse polarographic determination of Co(II) using moxifloxacine. Inam, R.; Mercan, H.; Yilmaz, E.; Uslu, B. // Journal of Analytical Chemistry;Jun2007, Vol. 62 Issue 6, p592 

    The polarographic reduction of Co(II) in the presence of moxifloxacin (1-cyclopropyl-7-[(S,S)-2.8-diazabicyclo[4.3.0]non-8-yl]-6-fluoro-8-methoxy-1.4-dihydro-4-oxo-3-quinolinecarboxylic acid) gives rise to an additional adsorption peak corresponding to the reduction of Co(II)-moxifloxacin...

  • Electrochemical Study of Pb+2-Theophylline Complex. Kumar, Yogesh; Meena, Om Prakash; Singh, Mahipat; Pandey, Rajayashree // International Journal of ChemTech Research;Oct2010, Vol. 2 Issue 4, p1907 

    The interaction between Theophylline and Pb2+ was investigated using direct current polarography. The polarographic technique was used to determine the stability constants and thermodynamic parameters such as enthalpy change (ΔH), free energy change (ΔG) and entropy change (ΔS) of...

  • ELECTROCHEMICAL BEHAVIOUR OF FOURTH-GENERATION FLUOROQUINOLONE ANTIBACTERIAL DRUG MOXIFLOXACIN BY DC POLAROGRAPHY AND CYCLIC VOLTAMMETRY. PANDEY, SHARDA; PANDEY, R. // International Journal of Pharmacy & Pharmaceutical Sciences;Apr2012 Supplement 3, Vol. 4, p349 

    Electrochemical behaviour of fluoroquinolone Antibiotic drug, moxifloxacin hydrochloride has been studied in aqueous medium using DC polarography and cyclic voltammetry. Moxifloxacin exhibits single well-defined cathodic peak in all the buffers like acetate buffer, phosphate buffer and...

  • Differential linear scan voltammetry: analytical performance in comparison with pulsed voltammetry techniques. Sheth, Disha; Gratzl, Miklós // Analytical & Bioanalytical Chemistry;Jun2013, Vol. 405 Issue 16, p5539 

    We report here on differential linear scan voltammetry, DLSV, that combines the working principles of linear scan voltammetry, LSV, and the numerous existing pulsed voltammetry techniques. DLSV preserves the information from continuous interrogation in voltage and high accuracy that LSV provides...

  • Differential Pulse Polarographic Determination of Cadmium After Solid Liquid Extraction and Preconcentration Using PAN. Taher, Mohammad Ali // Turkish Journal of Chemistry;2003, Vol. 27 Issue 4, p529 

    A highly selective, sensitive, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of cadmium in various samples after the adsorption of its 1-(2-pyridylazo)-2-naphthol (PAN) complex on microcrystalline naphthalene in the pH...

  • Votammetric Beviour and Analysis of Thiofanox in Environmental Samples. Minchala, Pushpalatha; Kodigutta, Balaji; Kumar, Chenna Rohini Putta; Chadive, Sridevi; Reddy, Suresh Cirandur // Der Pharma Chemica;2011, Vol. 3 Issue 2, p476 

    Electrochemical reduction behaviour of thiofanox has been carried out, by employing d.c. polarography, cyclic voltammetry, a.c. polarography and differential pulse polarography in the supporting electrolytes of the pH ranging from 2.0 to 12.0. Quantitative determination was carried out in the...

  • POLAROGRAPHIC STUDY OF THE ANTIGEN-ANTIBODY COMPLEX. Breyer, B.; Radcliff, F. J. // Australian Journal of Experimental Biology & Medical Science;Apr1953, Vol. 31 Issue 2, p167 

    Presents a polarographical study of the composition of antigen-antibody complexes. Techniques used in the study of antigen-antibody complexes; Advantages of using polarography in the study of complexes; Steps involved in polarography.

  • ELECTROCHEMICAL BEHAVIOUR OF FOURTH-GENERATION FLUOROQUINOLONE ANTIBACTERIAL DRUG MOXIFLOXACIN BY DC POLAROGRAPHY AND CYCLIC VOLTAMMETRY. PANDEY, SHARDA; PANDEY, R. // International Journal of Pharmacy & Pharmaceutical Sciences;Apr2012 Supplement 3, Vol. 4, p349 

    Electrochemical behaviour of fluoroquinolone Antibiotic drug, moxifloxacin hydrochloride has been studied in aqueous medium using DC polarography and cyclic voltammetry. Moxifloxacin exhibits single well-defined cathodic peak in all the buffers like acetate buffer, phosphate buffer and...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics