TITLE

Measurement of thermal conductivity of thin films with a Si-N membrane-based microcalorimeter

AUTHOR(S)
Zink, B. L.; Revaz, B.; Cherry, J. J.; Hellman, F.
PUB. DATE
February 2005
SOURCE
Review of Scientific Instruments;Feb2005, Vol. 76 Issue 2, p024901
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We describe a method of measuring thermal conductivity of films as thin as 15 nm from 2–300 K and in magnetic fields up to at least 8 T using a silicon-nitride membrane based microcalorimeter. The thermal transport in the membrane is measured before and after a sample film is deposited on the membrane. Accurate knowledge of the geometry of the microcalorimeter allows the thermal conductivity of the sample film to be determined from the difference of these measurements. We demonstrate the method for two thin film samples, a 16 nm thick Au film and a 200 nm Pb film. Results are in good agreement with the expected thermal conductivity. Below 10 K, surface scattering effects in the nitride membrane become important and limit the usefulness of this technique in some cases. Above 100 K radiative loss becomes important; we describe a method for correcting for this, taking advantage of its temperature dependence.
ACCESSION #
15877959

 

Related Articles

  • Design and performance of a thin-film calorimeter for quantitative characterization of photopolymerizable systems. Roper, Todd M.; Guymon, C. Allan; Hoyle, Charles E. // Review of Scientific Instruments;May2005, Vol. 76 Issue 5, p054102 

    A thin-film calorimeter (TFC) was designed for the quantitative characterization of photopolymerizable systems. A detailed description of its construction indicates the ease with which a TFC can be assembled and the flexibility inherent in its design. The mechanics of operation were optimized to...

  • Bottom electrode crystallization method for heat treatments on thin films. Joanni, E.; Mardare, A.I.; Mardare, C.C.; Marques, M.B. // Review of Scientific Instruments;Sep2004, Vol. 75 Issue 9, p2950 

    A simple method for crystallizing amorphous thin films was developed using platinum bottom electrodes as heating elements. A current was applied to tungsten wires in contact with the platinum and the temperature was measured using a type-K thermocouple. A proportional feedback algorithm was used...

  • Self-normalized photoacoustic technique for thermal diffusivity measurements of transparent materials. Balderas-López, J. A. // Review of Scientific Instruments;Feb2008, Vol. 79 Issue 2, p024901 

    A self-normalized photoacoustic methodology for thermal diffusivity measurements of thin foils of transparent materials is presented. The methodology implementation involves attaching a high optically opaque thin film on one of the transparent sample’s surface. The corresponding...

  • Relaxation calorimetry technique for measuring low temperature specific heat. Newsome Jr., R.W.; Andrei, E.Y. // Review of Scientific Instruments;Jan2004, Vol. 75 Issue 1, p104 

    A rudimentary calorimeter was constructed to measure the temperature dependence of the specific heat of a 10 μ thick (0.62 mg) copolymer film of vinylidene fluoride and trifluoroethylene in the previously unexplored vicinity of 6 K. The data were processed with the algorithm developed by...

  • Modulated-bath ac calorimetry using modified commercial Peltier elements. Lortz, Rolf; Abe, Satoko; Yuxing Wang; Bouquet, Frédéric; Tutsch, Ulrich; Junod, Alain // Review of Scientific Instruments;Oct2005, Vol. 76 Issue 10, p103903 

    We developed a type of ac microcalorimeter based on a modulated-bath technique for measuring the specific heat of small microgram samples in the temperature range from 30 to 300 K, and tested it in magnetic fields up to 14 T. The device is built from a modified commercial Peltier element. The...

  • Thermal calibration procedure for internal infrared laser deflection apparatus. Perpiñà, Xavier; Jordà, Xavier; Madrid, Francesc; Flores, David; Hidalgo, Salvador; Vellvehi, Miquel; Mestres, Narcís // Review of Scientific Instruments;Sep2005, Vol. 76 Issue 9, p094905 

    A procedure to calibrate the temperature measurements in the transient regime of internal IR-laser deflection (IIR-LD) apparatus is presented. For this purpose, a thermal test chip (TTC), whose behavior is analytically well described by a simple model, is used. During the calibration process,...

  • Thin film microcalorimeter for heat capacity measurements from 1.5 to 800 K. Denlinger, D. W.; Abarra, E. N.; Allen, Kimberly; Rooney, P. W.; Messer, M. T.; Watson, S. K.; Hellman, F. // Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p946 

    A new microcalorimeter for measuring heat capacity of thin films in the range 1.5-800 K is described. Semiconductor processing techniques are used to create a device with an amorphous silicon nitride membrane as the sample substrate, a Pt thin film resistor for temperatures greater than 40 K,...

  • Product News.  // Bioscience Technology;Jul2007, Vol. 32 Issue 7, p48 

    The article introduces several bioscience apparatus and consumables, including TX33 temperature transmitter from OMEGA Engineering Inc., absorbent disposable gloves from Parker Technology Corp. and RazorEdge Dichroic beamsplitters from Semrock Inc.

  • A concept to determine the true temperature of opaque materials using a tricolor pyroreflectometer. Hernandez, D. // Review of Scientific Instruments;Feb2005, Vol. 76 Issue 2, p024904 

    Despite the existence of several possible optical pyrometric methodologies, the determination of the true temperature has still not received a universal and perfect solution. We present here an analysis of our theoretical simulations and experimental measurements that have been carried out in...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics