Clinical experience with the Sorin Monolyth Oxygenator at high altitude

AUTHOR(S)
Steinberg, C.; Dragan, R.
PUB. DATE
January 1999
SOURCE
Perfusion;1999, Vol. 14 Issue 1, p77
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
High altitude combined with low barometric pressure can present unique challenges during cardiopulmonary bypass (CPB), not only for the perfusionist, but also for the oxygenator. Manufacturers of cardiopulmonary devices have responded to the requests from the perfusion community with a variety of oxygenators which balance low priming volumes and low pressure drops against high gas transfer. This paper will feature the first author's clinical studies using the Sorin Monolyth Oxygenator in a selected group of patients at an altitude of approximately 5200 feet and an average barometric pressure of 634 mmHg (sea level is 760 mmHg). A review of the 47 charts on patients requiring CPB and who met the selection criteria was performed retrospectively. To qualify for this study, the patient needed to weigh more than 91 kg. The data reviewed included type of surgery, age, weight, bypass time, crossclamp time, pump flows (l/min/m[sup 2]), hematocrits pre- and post-CPB, and pressure drop across the membrane. The PaO[sub 2], PaCO[sub 2], FiO[sub 2] and sweep gas flow at hypothermia and normothermia were recorded. Data concerning oxygen transfer were obtained from the manufacturer's report to the Food and Drug Administration. All patients had adequate blood gases while on CPB. We feel that the design of the Sorin Monolyth Oxygenator met our criteria for an oxygenator: low priming volume, low pressure drop, and sufficient gas transfer to provide safe oxygenation of all patients at high altitude.
ACCESSION #
1587753

 

Related Articles

  • Temporal Telemetering: Brain Programming. Dutton, Richard E. // Training & Development Journal;Feb68, Vol. 22 Issue 2, p20 

    Investigates the use of temporal telemetering as a means for occupational intelligence to keep pace with technology. Ways in which automation will change the labor structure; Introduction of certain chemicals into the brain shown to cause dramatic reactions; Programming of the human mind;...

  • Handheld assessment tool for telemetry.  // Materials Management in Health Care;Sep98, Vol. 7 Issue 9, p62 

    Features the Viridia Wave Viewer handheld assessment tool for telemetry. Key specifications; Contact information.

  • Optimized performance of the Abiomed BVS 5000: adjustment of the pump height based on Doppler control of the flow pattern. Lachat, M.; Jaggy, C.; Leskosek, B.; Zünd, G.; Künzli, A.; Vogt, P.; Turina, M.; Jenni, R.; Büchi, M. // Perfusion;1999, Vol. 14 Issue 1, p59 

    The Abiomed BVS 5000 is an automatic volume-driven paracorporeal pulsatile assist device providing left, right or biventricular support. The paracorporeal position allows optical adjustment of filling volumes of the device, which determines the output of the system. A procedure to adjust for...

  • Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer. Maiolo C; Melchiorri G; Iacopino L; Masala S; De Lorenzo A // British Journal of Sports Medicine;Oct2003, Vol. 37 Issue 5, p445 

    BACKGROUND: Several studies have evaluated the accuracy of portable metabolic gas analysis systems, which measure physical activity energy expenditure. Since the Cosmed K2 telemetric system, two K4 devices (RQ and b2) have been developed. OBJECTIVE: To compare measurements using the Cosmed K4 RQ...

  • Where analytics meets oenology. Scollary, Geoffrey R. // Chemistry in Australia;Oct2013, p39 

    The article offers information on the eighth symposium in the In Vino Analytica Scientia conference series at the University of Reims in France, in July 2013. The symposium addressed topics including chemical analysis and composition; chemical and biochemical reactions; sensors/biosensors;...

  • Implications of fitting monitoring devices to wild animals. Grogan, Adam; Wilson, Rory; Vandenabeele, Sylvie // Veterinary Record: Journal of the British Veterinary Association;12/3/2011, Vol. 169 Issue 23, p613 

    A letter to the editor is presented concerning the implications of fitting telemetry equipment to free-living wild birds.

  • The Use of Telemetric Oximetry In the Clinical Setting. Martin, Barbara; Llewellyn, Jane; Faut-Callahan, Margaret; Meyer, Peter // MEDSURG Nursing;Apr2000, Vol. 9 Issue 2, p71 

    Discusses a study which evaluated the reliability and ease of use of a combined functions-cardiac telemetry and telemetric pulse oximetry system. Definition of oxygen saturation; Revisions and development on pulse oximetry monitoring; Uses of pulse oximetry.

  • Novel Micro-Probe Sensors for Real-time Measurement of ATP/Purines in the Brain.  // Medical Device Technology;Sep2005, Vol. 16 Issue 7, p48 

    Focuses on the development of a new generation of micro-probe sensors capable of enabling point-of-care testing of respiratory and brain function in Great Britain. Utilization of a platinum needle in the biosensor; Capability to measure purine production in real-time biochemical reactions in...

  • A new, lightweight fetal telemetry system. Boos, Andreas; Houghton, Michelle; al, et // Hewlett-Packard Journal;Dec95, Vol. 46 Issue 6, p82 

    Features Hewlett-Packard Co.'s Series 50 T fetal telemetry system. Specifications; Capabilities; Radio frequency bandwidth.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics