Ce3+-doped fibers for remote radiation dosimetry

Vedda, A.; Chiodini, N.; Di Martino, D.; Fasoli, M.; Keffer, S.; Lauria, A.; Martini, M.; Moretti, F.; Spinolo, G.; Nikl, M.; Solovieva, N.; Brambilla, G.
December 2004
Applied Physics Letters;12/27/2004, Vol. 85 Issue 26, p6356
Academic Journal
A radioluminescent (RL) dosimetric system, based on a SiO2 optical fiber with the core doped by Ce3+ ions as luminescent activators has been investigated. Structural and optical properties of the luminescent fiber have been studied by Raman, refractive index, RL and scintillation time decay measurements, and compared to those obtained on bulk material. The RL response of a composite fiber made of a short portion of active Ce-doped fiber coupled to a long commercial one has been investigated by x-ray irradiation. A linear RL intensity response has been found in the dose rate interval 6×10-3–40 mGy/s together with a good radiation hardness, suggesting possible application in low-dose monitoring.


Related Articles

  • COMMERCIAL OPTICAL FIBRE AS TLD MATERIAL. Espinosa, G.; Golzarri, J. I.; Bogard, J.; Garcia-Macedo, J. // Radiation Protection Dosimetry;2006, Vol. 119 Issue 1-4, p197 

    This work presents a study of commercial SiO2 optical fibre thermoluminescence (TL) properties as part of the efforts within the Dosimetric Application Project at the Physics Institute of the University of Mexico to develop new radiation detection materials and technologies. The SiO2 commercial...

  • Performance and approval procedures for active personal dosemeters. Ginjaume, M. // Radiation Protection Dosimetry;Mar2011, Vol. 144 Issue 1-4, p144 

    Active personal dosemeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. The increasing concern about studying the behaviour of APDs in pulsed fields is illustrated through revision of the results of the most representative studies on the...

  • THE SUNLIGHT OSL RESPONSE OF A COMMERCIALLY AVAILABLE α-Al2O3:C PERSONNEL DOSIMETRY MATERIAL. West, W. G.; Kearfot, K. J.; Bernal, S. M. // Radiation Protection Dosimetry;2006, Vol. 119 Issue 1-4, p344 

    Carbon-doped, anion-defective aluminium oxide has become a widely used and effective medium for personnel dosimetry applications using optically stimulated luminescence (OSL) techniques. Though the commercial products currently using this material employ light-tight packaging to prevent...

  • Calibrative Densities for Radiation Dosimeters. Groer, Peter G.; Ramachandran, Ravichandran // AIP Conference Proceedings;2004, Vol. 735 Issue 1, p104 

    Focuses on calibrative densities for radiation dosimeters. Derivation of calibrative densities for the unknown "future" dose to a dosimeter for calibration data for film and thermoluminescent dosimeters; Equation for the calibrative density for a controlled calibration experiment.

  • A whole-body dosimetry system for personal monitoring based on hot-pressed thin layer TLD. Busch, F.; Engelhardt, J.; Martini, E.; Lesz, J. // Radiation Protection Dosimetry;Mar2011, Vol. 144 Issue 1-4, p246 

    We are introducing a new high-capacity thermoluminescent dosemeter (TLD) system to measure the whole body values of Hp(10) and Hp(0.07) from photons for use in individual monitoring services. Small and light-weight badges allow a convenient application in a wide variety of workplaces with photon...

  • Practical low dose limits for passive personal dosemeters and the implications for uncertainties close to the limit of detection. Gilvin, P. J.; Perks, C. A. // Radiation Protection Dosimetry;Mar2011, Vol. 144 Issue 1-4, p102 

    Recent years have seen the increasing use of passive dosemeters that have high sensitivities and, in laboratory conditions, detection limits of <10 µSv. However, in real operational use the detection limits will be markedly higher, because a large fraction of the accrued dose will be due to...

  • THE 12B COUNTER: AN ACTIVE DOSEMETER FOR HIGH-ENERGY NEUTRONS. Leuschner, A. // Radiation Protection Dosimetry;2005, Vol. 116 Issue 1-4, p144 

    High-energy accelerators can produce strong time-structured radiation fields. Such dose shots are generated at linear machines with low duty cycles as well as at circular machines when complete fills are instantaneously lost. The main dose component behind thick shielding is due to high-energy...

  • Individual monitoring for external radiation at accelerator facilities. Tanner, R. J.; Hager, L. G. // Radiation Protection Dosimetry;Jul2011, Vol. 146 Issue 4, p395 

    Individual monitoring at accelerator facilities is discussed, within the framework set out by the International Commission on Radiological Protection and with reference to the implementation of the recommendations of that body within the European Basic Safety Standards. Legislation in other...

  • Organ biodistribution of Germanium-68 in rat in the presence and absence of [68Ga]Ga-DOTA-TOC for the extrapolation to the human organ and whole-body radiation dosimetry. Velikyan, Irina; Antoni, Gunnar; Sörensen, Jens; Estrada, Sergio // American Journal of Nuclear Medicine & Molecular Imaging;2013, Vol. 3 Issue 2, p154 