TITLE

Continuous Airway Pressure Monitoring

AUTHOR(S)
Burns, Suzanne M.
PUB. DATE
December 2004
SOURCE
Critical Care Nurse;Dec2004, Vol. 24 Issue 6, p70
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents information on continuous airway pressure monitoring (CAPM). Components of CAPM; Association of CAPM with patient-ventilator asynchrony; Role of CAPM in the interpretation of hemodynamic waveforms; Use of CAPM in monitoring patients that require muscle relaxants.
ACCESSION #
15351625

 

Related Articles

  • The Failing Heart Under Stress: Echocardiography is an Essential Monitoring Tool in the Intensive Care Unit. Poelaert, Jan // Seminars in Cardiothoracic & Vascular Anesthesia;Mar2006, Vol. 10 Issue 1, p111 

    Echocardiography has been evolving to play a pivotal role in hemodynamic management, both intraoperatively and at the bedside. A full assessment of hemodynamics necessitates the use of all of the options available on modern echocardiographs. This introductory review provides insight into three...

  • Hemodynamic monitoring development: helpful technology or expensive luxury? Bendjelid, Karim // Journal of Clinical Monitoring & Computing;Oct2012, Vol. 26 Issue 5, p337 

    The author present his views on recent advances in hemodynamic monitoring to manage critically ill patients. He notes that survival rate did not improve despite increased availability of the monitoring process and monitoring equipment. He also mentions the increasing cost of these hemodynamic...

  • Comparison of two induction regimens using or not using muscle relaxant: impact on postoperative upper airway discomfort. X. Combes; L. Andriamifidy; E. Dufresne; P. Suen; S. Sauvat; E. Scherrer; P. Feiss; J. Marty; P. Duvaldestin // BJA: The British Journal of Anaesthesia;Jul2007, Vol. 99 Issue 2, p276 

    : Background Muscle relaxants facilitate tracheal intubation, but they are often not used for short peripheral surgical procedures. The consequences of this practice on the upper airway are still a matter of controversy. We therefore compared the incidence of post-intubation symptoms in a...

  • Effects of neuromuscular block on systemic and cerebral hemodynamics and bispectral index during moderate or deep sedation in critically ill patients. Inoue, Satoki; Kawaguchi, Masahiko; Sasaoka, Noriyuki; Hirai, Katsuji; Furuya, Hitoshi // Intensive Care Medicine;Mar2006, Vol. 32 Issue 3, p391 

    Objective: To investigate whether neuromuscular block can affect bispectral index (BIS) or cerebral hemodynamics under moderate or deep sedation produced by propofol. Design and setting: Prospective, controlled study in a university hospital affiliated intensive care unit. Patients: Seventeen...

  • Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Vallée, Fabrice; Fourcade, Olivier; De Soyres, Olivier; Angles, Olivier; Sanchez-Verlaan, Pascale; Pillard, Fabien; Smail, Nadia; Olivier, Michel; Genestal, Michèle; Samii, Kamran // Intensive Care Medicine;Oct2005, Vol. 31 Issue 10, p1388 

    Objective: Esophageal Doppler allows continuous monitoring of stroke volume index (SVI) and corrected flow time (FTc). We hypothesized that variations in stroke output index SOI (SVI/FTc) during volume expansion can predict the hemodynamic response to subsequent fluid loading better than the...

  • Bedside Hemodynamic Monitoring in the Management of Acute Cardiac Patients. Hutchison, S. J.; Rankin, A. C.; Hutton, I. // Angiology;Oct1986, Vol. 37 Issue 10, p702 

    Hemodynamic monitoring was performed in 100 acutely ill patients admitted to a Coronary Care Unit, 72 of whom had sustained an acute myocardial infarction (AM1). In patients with AM!, the initial pulmonary capillary wedge (PCW) pressure was related to prognosis, with a mortality of 68% in those...

  • Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Reuter, Daniel A.; Felbinger, Thomas W.; Schmidt, Christian; Kilger, Erich; Goedje, Oliver; Lamm, Peter; Goetz, Alwin E. // Intensive Care Medicine;Apr2002, Vol. 28 Issue 4, p392 

    Objective: We hypothesized that measuring stroke volume variation (SVV) during mechanical ventilation by continuous arterial pulse contour analysis allows the accurate prediction and monitoring of changes in cardiac index (CI) in response to volume administration. Design and setting: Prospective...

  • EDWARDS PREVIEWS MINIMALLY INVASIVE HEART MONITOR.  // Biotech Equipment Update;Mar2005, p5 

    The article reports that Edwards Lifesciences Corp., a global leader in hemodynamic monitoring technologies, has previewed its Edwards FloTrac sensor, a new minimally invasive hemodynamic monitoring device, at the Society of Critical Care Medicine's 34th Critical Care Congress. The sensor's...

  • Noninvasive monitoring of peripheral perfusion. Lima, Alexandre; Bakker, Jan // Intensive Care Medicine;Oct2005, Vol. 31 Issue 10, p1316 

    Background: Early hemodynamic assessment of global parameters in critically ill patients fails to provide adequate information on tissue perfusion. It requires invasive monitoring and may represent a late intervention initiated mainly in the intensive care unit. Noninvasive monitoring of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library