TITLE

High-throughput microwave-digestion procedures to monitor neurotoxic elements in body fluids by means of inductively coupled plasma mass spectrometry

AUTHOR(S)
Bocca, B.; Alimonti, A.; Forte, G.; Petrucci, F.; Pirola, C.; Senofonte, O.; Violante, N.
PUB. DATE
September 2003
SOURCE
Analytical & Bioanalytical Chemistry;Sep2003, Vol. 377 Issue 1, p65
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Microwave (MW) digestion procedures with high sample throughput (simultaneous digestion of 36 or 80 samples) and procedural simplicity (disposable plastic tubes, or re-usable liners with screw-cap) were investigated for their efficiency in routine analyses of biological samples. Different digestion vessel materials were tested for metal leaching/adsorption and thermal resistance: quartz, glass, polyethylene (PE) and polystyrene (PS). For the instrumental quantification of Al, Bi, Cd, Co, Cr, Hg, Mn, Mo, Ni, Pb, Sb, and Tl at ultra-trace levels in urine, serum, and whole blood, sector field inductively coupled plasma mass spectrometry (SF-ICP–MS) was used. The different pretreatment conditions and vessels were evaluated in terms of contamination risk, effective power of detection, accuracy, and precision. Results of analyses of serum, urine and whole blood certified reference materials (CRMs) were fully satisfactory for almost all the analytes. In the case of Hg, Mo, and Tl in serum digested in plastic containers the results were just below the lower limit of uncertainty of the certified range. On the basis of the present data the following MW procedures can be suggested:1.for urine, digestion with nitric acid at atmospheric pressure in plastic vials;2.for serum, digestion with nitric acid at atmospheric pressure in glass vessels; and3.for whole blood, digestion under pressure in quartz tubes.Because of the levels of the procedural blanks, Bi was not measurable at the concentrations expected in human fluids, and Al was accurately detectable in whole blood only.
ACCESSION #
15125883

 

Related Articles

  • Single Reaction Chamber Microwave Digestion of Highly Organic Matrices. Gunn, David // Spectroscopy;Feb2014 Supplement Application NoteBook, p8 

    The article focuses on single reaction chamber technology for digesting several sample types including difficult catalysts and highly organic samples. It further presents several tables including Mixed organic samples for digestion and Inductively coupled plasma mass spectrometry analysis of...

  • A Beginner's Guide to ICP-MS. Thomas, Robert // Spectroscopy;Jun2001, Vol. 16 Issue 6, p26 

    Part III. Discusses the fundamental principles behind the creation of an inductively coupled plasma (ICP) in ICP-mass spectroscopy. Components of a plasma torch; Details on the formation of an ICP discharge; Frequencies used in ICP radio frequency generators; Result of the ionization of the...

  • Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion. Heilmann, Jens; Boulyga, Sergei F.; Heumann, Klaus G. // Analytical & Bioanalytical Chemistry;Sep2004, Vol. 380 Issue 2, p190 

    Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel...

  • Determination of Lead in Saudi Arabian Imported Green Tea by ICP-MS. Othman, Ahmed; Al-Ansi, Seham; Al-Tufail, Mohammed // E-Journal of Chemistry;2012, Vol. 9 Issue 1, p79 

    Lead (Pb) in nine different Saudi Arabian imported green tea samples originated from China has been determined using inductively coupled plasma mass spectrometry (ICP-MS). Tea infusion and microwave acid digestion procedures are used for sample pre-treatment. The concentrations range of lead...

  • Determination of gold and antimony in advanced materials based on tin dioxide using inductively coupled plasma mass spectrometry. Turkin, A.; Chizhov, A.; Seregina, I.; Filatova, D.; Karpov, Yu. // Inorganic Materials;Dec2015, Vol. 51 Issue 14, p1420 

    An approach to determination of modifying additives in new materials based on SnO in solutions using inductively coupled plasma mass spectrometry (ICP-MS) after microwave digestion in a mixture of acids is proposed. On the basis of the studies performed, a method of determination of Au and Sb is...

  • Supplementary File.  // Molecules;Apr2014, Vol. 19 Issue 4, pS1 

    Tables are presented which provide information on the operating conditions and parameters of inductively coupled plasma-mass spectrometry (ICP-MS) and the ultrawave single reaction chamber microwave digestion system, the Box-Behnken experimental design, and the correlation matrix of principal...

  • Determination of chemical elements in biological fluids and diagnostic substrates from children by inductively coupled plasma mass spectrometry. Seregina, I.; Lanskaya, S.; Okina, O.; Bol’shov, M.; Lyapunov, S.; Chugunova, O.; Foktova, A. // Journal of Analytical Chemistry;Sep2010, Vol. 65 Issue 9, p964 

    Inductively coupled plasma mass spectrometry was used to analyze diagnostic substrates from newborns and primary school-aged children. We studied urine and blood samples of children aged from several days to 2 months and hair samples of primary school-aged children. Methods for the collection of...

  • Determination of gallium in biological fluids using inductively coupled plasma mass spectrometry. Filatova, D.; Seregina, I.; Osipov, K.; Foteeva, L.; Pukhov, V.; Timerbaev, A.; Bol'shov, M. // Journal of Analytical Chemistry;Feb2013, Vol. 68 Issue 2, p106 

    A procedure for the determination of gallium in biological fluids by inductively coupled plasma mass spectrometry was developed. The detection limits of gallium calculated from the 3 s value were 60 ng/L for urine, 32 ng/L for a model solution of intestinal juice, and 50 ng/L for serum. The...

  • Market Profile: ICP-MS.  // Spectroscopy;Jan2001, Vol. 16 Issue 1, p12 

    Features inductively coupled plasma mass spectrometry (ICP-MS), an instrument used for determining trace element concentrations in inorganic solids and liquids. Key Features; Forecast on the demand for ICP-MS.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.